![Heatiator NEVO3630I Owner'S Manual Download Page 55](http://html.mh-extra.com/html/heatiator/nevo3630i/nevo3630i_owners-manual_2116935055.webp)
Heatilator • Evolution • 4065-114 Rev. o • 11/11
55
B. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing
and/or
fi nishing materials must not interfere with
air fl ow through louvers, operation of louvers or doors,
or access for service.
• Facing
and/or
fi nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
Figure 14.4 Non-combustible Facing Diagram
• Seal joints between the fi nished wall and appliance top
and sides using a 300 °F minimum sealant. Refer to
Figure 14.4.
WARNING! Risk of Fire! DO NOT apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as specifi ed in this
manual. Overlapping materials could ignite and will inter-
fere with proper operation of doors and louvers.
Note:
If using the optional fi nishing trim for the Modern
Front facing, fi nish wall material must not be installed
within 3 in. (76 mm) of the fi replace opening. See
Figure 14.5.
3 in. (76 mm)
3 in.
(76 mm)
3 in.
(76 mm)
Gray shading represents
clearance needed for optional
Finishing Trim that may be used
with the Modern Front. No facing
material may be used within the
shaded area.
Figure 14.5 Clearance for Optional FInishing Trim (Modern Front)
42.25 in. (NEVO3630)
48.25 in. (NEVO4236)
1/8 in. reveal
all sides
30.22 in.
6 in.
6 in.
Figure 14.3 Marble/Granite Cut Dimensions
• Figure 14.3 shows the dimensions for cutting marble/
granite if the optional Finishing Trim is not used.
• The dimensions given assume a 1/8 in. reveal around
the fi replace opening.
Note:
Fireplace MUST be elevated
1 1/2 in. (38 mm) off fl oor
0 in.
0 in.
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
0 in.
Finish wall material may be
combustible - Top and Sides