![Heatiator GDCH60 Series Owner'S Manual Download Page 4](http://html.mh-extra.com/html/heatiator/gdch60-series/gdch60-series_owners-manual_2116929004.webp)
4
Heatilator • Caliber Multi-Sided Direct Vent • 4002-079 Rev K • 11/07
1
Listing and Code Approvals
A. Appliance Certi
¿
cation
This product is listed to ANSI standards for “Vented Gas
Fireplaces” and applicable sections of “Gas Burning Heat-
ing Appliances for Manufactured Homes and Recreational
Vehicles”, and “Gas Fired Appliances for Use at High Alti-
tudes”.
Do NOT use this appliance if any part has been under
water. Immediately call a quali
¿
ed service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
WARNING
MODELS:
GDCH60, GDST60, GDFL60, GDCR60,
GDCL60
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Direct Vent Gas Appliance
STANDARD:
ANSI Z21.50b-2005/•CSA2.22b-2005
/UL307B
NOT INTENDED FOR USE AS A PRIMARY HEAT
SOURCE.
This appliance is tested and approved as either
supplemental room heat or as a decorative appliance. It
should not be factored as primary heat in residential heating
calculations.
Note:
This installation must conform with local codes. In the
absence of local codes you must comply with the
National
Fuel Gas Code, ANSI Z223.1-latest edition
in the U.S.A.
and the
CAN/CGA B149 Installation Codes
in Canada.
B. Glass Speci
¿
cations
Hearth & Home Technologies appliances manufactured with
tempered glass may be installed in hazardous locations such
as bathtub enclosures as de
¿
ned by the Consumer Product
Safety Commission (CPSC). The tempered glass has been
tested and certi
¿
ed to the requirements of
ANSI Z97.1
and
CPSC 16 CFR 1202
(Safety Glazing Certi
¿
cation Council
SGCC# 1595
and
1597
. Architectural Testing, Inc. Reports
02-31919.01
and
02-31917.01
).
This statement is in compliance with
CPSC 16 CFR Section
1201.5
“Certi
¿
cation and labeling requirements” which refers
to
15
U.S. Code
(USC) 2063
stating “…Such certi
¿
cate shall
accompany the product or shall otherwise be furnished to
any distributor or retailer to whom the product is delivered.”
Some local building codes require the use of tempered glass
with permanent marking in such locations. Glass meeting
this requirement is available from the factory. Please contact
your dealer or distributor to order.
C. BTU Speci
¿
cations
D. High Altitude Installations
U.L. Listed gas appliances are tested and approved without
requiring changes for elevations from 0 to 2000 feet in the
U.S.A. and Canada.
When installing this appliance at an elevation above 2000 ft,
it may be necessary to decrease the input rating by chang-
ing the existing burner ori
¿
ce to a smaller size. Input rate
should be reduced by 4% for each 1000 ft above a 2000 ft
elevation in the U.S.A., or 10% for elevations between 2000
and 4500 ft in Canada. If the heating value of the gas has
been reduced, these rules do not apply. To identify the prop-
er ori
¿
ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 ft (in
Canada), check with local authorities.
E. Non-Combustible Materials
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing
ASTM E 136, Stan-
dard Test Method for Behavior of Materials in a Vertical
Tube Furnace at 750° C,
shall be considered non-combus-
tible materials.
F. Combustible Materials
Materials made of or surfaced with wood, compressed pa-
per, plant
¿
bers, plastics, or other material that can ignite and
burn, whether
À
ame proofed or not, or whether plastered or
unplastered shall be considered combustible materials.
Caliber
Multi-sided DV
Standing Pilot
Max/Min Input Rate (NG)
34,000/21,000
Ori
¿
ce Size (NG)
.115 in./2.92 mm
Max/Min Input Rate (LP)
30,000/21,000
Ori
¿
ce Size (LP)
.063 in./1.60 mm
IPI
Max/Min Input Rate (NG)
34,000/25,000
Ori
¿
ce Size (NG)
.115 in./2.92 mm
Max/Min Input Rate (LP)
30,000/22,000
Ori
¿
ce Size (LP)