3
598-1147-00
Motion
Motion
TEST AND ADJUSTMENT
❒
Turn on the circuit breaker and light switch.
Sensor
The detector is most sensitive to motion across its field
of view.
❒
Loosen the clamp screw in the
sensor ball joint and gently ro-
tate the sensor.
❒
Walk through the coverage area
noting where you are when the
lights turn on (also, the LED will
flash several times when mo-
tion is detected). Move the sen-
sor head up, down, or sideways
to change the coverage area.
Keep the sensor at least 1"
(2.5 cm) away from the lamps.
❒
Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 10 minutes).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . . Up to 180
°
Electrical Load . . . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . . 1 , 5, 10 minutes
DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
NOTE:
Sensor has about 1
1
/
2
minutes warm up
period before it will detect motion. When first
turned on, wait about 1
1
/
2
minutes.
RANGE
10 5 1 TEST
ON-TIME
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
180
°
MIN
MAX
70 ft.
(21 m)
8 ft.
(2.4 m)
❒
Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
Least Sensitive
Most Sensitive
Maximum Range
Maximum
Coverage Angle