3
595-5295-12
TEST AND ADJUSTMENT
❒
Turn on the circuit breaker and light switch.
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners.
These heat
sources could cause false triggering.
• Areas where
pets or traffic
may trigger the control.
•
Nearby large, light-colored objects
reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
NOTE:
Sensor has about 1
1
/
2
minutes warm up period
before it will detect motion. When first turned
on, wait about 1
1
/
2
minutes.
RANGE
10 5 1 TEST
ON-TIME
Bottom of Sensor
MIN
MAX
Maximum Range
Maximum
Coverage Angle
70 ft.
(21 m)
8 ft.
(2.4 m)
Least Sensitive
Most Sensitive
The detector is most sensitive to motion across its field
of view.
❒
Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒
Walk through the coverage area
noting where you are when the
lights turn on (also, the LED will
flash several times when motion
is detected). Move the sensor
head up, down, or sideways to
change the coverage area.
Keep
the sensor at least 1" (2.5
cm) away from the lamp.
❒
Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒
Set the amount of TIME you
want the lights to stay on after motion is detected
(1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . Up to 180°
Electrical Load . . . . . . . Up to 250 Watts Maximum
Incandescent.
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . 1, 5, 10 minutes
Replacement lamp . . . . T3, 250W (or less) halogen
120 VAC
HeathCo LLC reserves the right to discontinue products
and to change specifications at any time without incurring
any obligation to incorporate new features in products
previously sold.
180°
Motion
Motion
Sensor
❒
Turn the RANGE control to the mid position and
the ON-TIME control to the TEST position.
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage