background image

2

595-5766-03

INSTALLATION

For easy installation, select an existing light with a wall
switch for replacement.

W

IRE

 

THE

 L

IGHT

 C

ONTROL

.

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Install the mounting strap as shown using two screws
that fit your junction box.

The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger can
be threaded through the hole in the center of the
cover plate. The small end then goes into one of the
slots on the mounting strap.

Route the Light Control’s wires through the large
gasket holes.

Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.

M

OUNT

 

THE

 L

IGHT

 C

ONTROL

.

Align the Light Control cover plate and cover plate
gasket. Secure with the mounting bolt.

Push the Rubber Plug firmly into place.

If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.

White to
White

Lock Nut

To avoid water damage and
electrical shock, keep lamp
holders 30

°

 below horizontal.

Black to
Black

Junction box ground wire to
green ground screw on fixture.

Gasket

For eave mount only:

Swing the sensor head towards the clamp screw
joint.

If the sensor pops out of the ball joint, loosen the clamp
screw and push the sensor back into the ball joint.
Tighten the clamp screw when done.

Then rotate the sensor head clockwise 180

°

 so the

controls face down.

Controls

Wall Mount

Eave Mount

For under eave installation, the sensor head must
be rotated
 as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.

1234567890123456789

1234567890123456789

1234567890123456789

Mounting

Strap

Mounting

Bolt

Controls

Controls

Clamp Screw

Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180

°

from the factory setting. When screwing in the
floodlamps, do not overtighten.

Keep lamps at least
1" (2.5 cm) from the
sensor. Do not al-
low the lamps to
block the lens.

Lens

Rubber

Plug

Summary of Contents for SL-5411

Page 1: ...ents The Light Control requires 120 volts AC If you want to use Manual Mode the control must be wired through a switch Some codes require installation by a qualified electrician This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations Model SL 5411 Light Control Sensor Cover Plate Lamp Holders Features Turns on lighting when motion is detect...

Page 2: ...g surface with silicone weather sealant White to White Lock Nut To avoid water damage and electrical shock keep lamp holders 30 below horizontal Black to Black Junction box ground wire to green ground screw on fixture Gasket For eave mount only Swing the sensor head towards the clamp screw joint If the sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball ...

Page 3: ... Up to 300 Watt Maximum In candescent Up to 150 Watt maximum each lamp holder Power Requirements 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE Time Delay 1 5 10 minutes DESA Specialty Products reserves the right to dis continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold NOTE Sensor has a 1 1 2...

Page 4: ...IBLE CAUSE 1 A flood lamp is positioned too close to the sensor or pointed at nearby ob jects that cause heat to trigger the sensor Reposition the lamp away from the sensor or nearby objects 2 Light Control is pointed toward a heat source like an air vent dryer vent or brightly painted heat reflective sur face Reposition sensor 3 Light Control is in Manual Mode Switch to Auto 1 Heat or light from ...

Page 5: ...BA AUTOM MODO MANUAL Requisitos El Control de Luz requiere 120 VCA Para usar el Sobrecontrol Manual conecte el control con un interruptor Algunos códigos requieren instalación por un electricista calificado Se recomienda usar este producto con el empaque provisto y con una caja de empalme marcada para uso en lugares húmedos Modelo SL 5411 Control de luz Detector Placa cubertora Portalámparas Carac...

Page 6: ...lo sujetador cuando termine Entonces gire la cabeza del detector hacia la derecha por 180 hasta que los controles miren hacia abajo Controles Montaje en pared Montaje en alero Para instalarlo bajo el alero la cabeza del detector debe ser girada como se muestra en los dos pasos siguientes para evitar el riesgo de un choque eléctrico 1234567890123456789 1234567890123456789 1234567890123456789 lámina...

Page 7: ...ty Products se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de tener que incorporar nuevas características en los productos vendidos con anterioridad NOTA El detector tiene un período de cerca de 1 1 2 minutos de calentamiento antes de detectar movimiento Cuando lo prenda por primera vez espere 1 1 2 minutos RANGE...

Page 8: ...ado alta Reduzca la sensibilidad SINTOMA La luz se queda prendida continuamente La luz se prende y se apaga POSIBLE CAUSA 1 Unfaroestácolocadodemasiadocerca aldetectoroapuntaaobjetoscercanos quehacequeelcaloractiveeldetector Reposicione la lámpara lejos del de tector o de los objetos cercanos 2 El Control de Luz está apuntando hacia una fuente de calor tal como un conductodeaire desecadoraohacia u...

Page 9: ...terrupteur Certainscodesdebâtimentlocauxpeuventexiger que l installation soit faite par un électricien qualifié Ce produit est conçu pour être utilisé avec une boîte de jonction portant une indication d utilisation pos sible en milieu humide Modèle SL 5411 Commande d éclairage Détecteur Plaque de garde Douilles de lampe Caractéristiques Allume l éclairage lorsqu un mouvement est détecté Éteint aut...

Page 10: ...tage sous avant toit Pour éviter le risque de choc électrique les commandes du détecteur doivent être tournées vers le bas 1234567890123456789 1234567890123456789 1234567890123456789 Bride de montage Commandes Commandes Vis De Blocage silicone Ajuster les porte lampes en desserrant les écrous de blocage mais ne pas faire tourner les porte lampes deplusde180 parrapportauréglaged usine Nepas trop se...

Page 11: ...er tout produit et d en changer les spécifications entouttempsetsanscontracterquelque obligation que ce soit quant à l incorporation de nouvelles caractéristiques aux produits déjà vendus NOTE Lecapteurdoitseréchauffer11 2 minuteavant de pouvoir détecter le mouvement Lorsque l appareil est mis en circuit attendre 1 1 2 minute RANGE 10 5 1 TEST ON TIME Bas du détecteur Éviter de pointer l appareil ...

Page 12: ...rtée SYMPTÔME L éclairage reste allumé continuellement L éclairage clignote CAUSE POSSIBLE 1 Un projecteur est situé trop près du détecteur ou pointé vers des objets etlachaleurdéclencheledétecteur Repositionnezleprojecteurloindu détecteuroudesobjetsrapprochés 2 La commande d éclairage est pointéeversunesourcedechaleur comme un évent une sortie de sécheuse ou une surface claire qui réfléchit la ch...

Reviews: