SPECIFICATIONS

Range . . . . . . . . . . . . . Up  to  70  ft.  (21  m);  100  ft. 

(30.5  m)  with  Range  Boost. 
[varies  with  surrounding 
temperature]

Sensing Angle . . . . . . . Up to 240°
Electrical Load . . . . . . . Up  to  500  Watt  Maximum 

Incandescent

Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST,  AUTO  and  MANUAL 

MODE

Time Delay  . . . . . . . . . 1, 5, 20 minutes
Replacement lamp . . . . T 500W (or less) halogen 120 

VAC 

D

ual

B

rite

®

 Timer . . . . . 3, 6 hours, Dusk-to-Dawn

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features in 
products previously sold.

Motion

TEST AND ADJUSTMENT

 

Turn on the circuit breaker and light switch.

NOTE:

  Sensor has a 1 

1

/

2

 minute warm up period be-

fore it will detect motion. When first turned on 
or when switching modes wait 1 

1

/

2

 minutes.

Bottom of Sensor

Avoid aiming the sensor at:

•  Objects  that  change  temperature  rapidly,  such  as 

heating  vents  and  air  conditioners.

  These  heat 

sources could cause false triggering.

•  Areas where 

pets or traffic

 may trigger the control.

•  

Nearby large, light-colored objects

 reflecting light 

may trigger the shut-off feature. Do not point other 
lights at the sensor.

 

Maximum Range 

Maximum

 

 

Coverage Angle

8 ft. 

(2.4 m)

 

70 ft. 

100 ft. 

 

(21 m)  (30.5 m)

 

 

Boosted

  Least Sensitive 

Most Sensitive

Sensor

The detector is less sensitive to motion directly towards it.

240°

B

O

O

S

T

MAX

MIN

RANGE

ON - TIME DUAL BRITE

TEST  1   5   2 0

MINUTES

OFF  3  6   DUSK TO

HOUR   DAWN

  Turn  the  RANGE  control  to  the  mid  position, 

D

ual

B

rite

®

 to OFF and the ON-TIME control to the 

TEST position.

  Loosen the clamp screw in the 

sensor  ball  joint  and  gently 
rotate the sensor.

  Walk  through  the  coverage 

area  noting  where  you  are 
when the lights turn on. Move 
the  sensor  head  up,  down, 
or  sideways  to  change  the 
coverage area.

  Adjust the RANGE as needed. 

RANGE  set  too  high  may 
increase false triggering.

 

Secure  the  sensor  head’s 
aim by tightening the clamp 
screw.

 Do not overtighten the 

screw.

  Set the amount of TIME you 

want the lights to stay on after 
motion is detected (1, 5, or 20 minutes).

  Set  the  D

ual

B

rite

®

  switch  to  the  amount  of  time 

after dusk you want the lights on at low level (Off, 
3, 6 Hrs., Dusk-to-Dawn).

Clamp 
Screw

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

Motion

Summary of Contents for SL-5311

Page 1: ...EST 1 5 20 ON TIME Off 3 6 Dusk to DualBrite Put ON TIME switch on the sensor bottom to TEST and the Dual Brite switch OFF MANUAL MODE ON TIME TEST 1 5 20 back on AUTO 1 Second OFF then Move ON TIME Switch to 1 5 or 20 minutes Mode Switching Summary Flip light switch off for one second then back on MANUAL MODE AUTO TEST Note When first turned on wait about 1 1 2 minutes for the circuitry to calibr...

Page 2: ... an existing light with a wall switch for replacement Attach the lamp arm to the backplate arm and secure with the long bolt Note Whentighteningthearm screw pullonthewirestomake sure the wires are not pinched by the joint Remove the existing light fixture The S hook can be used to hold the fixture while wiring The small end of the hook can be inserted into a hole in the junction box The large end ...

Page 3: ... control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor Maximum Range Maximum Coverage Angle 8 ft 2 4 m 70 ft 100 ft 21 m 30 5 m Boosted Least Sensitive Most Sensitive Sensor The detector is less sensitive to motion directly towards it 240 B O O S T MAX MIN RANGE ON TIME DUAL BRITE TEST 1 5 2 0 MINUTES OFF 3 6 DUSK TO HO...

Page 4: ... negligence light bulbs batteries and other expend able items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for inconvenience installation setup time loss of use unauthorized service or return shipping charges This warranty covers only HeathCo LL...

Page 5: ... Para AUTOMATICO Resumen de las modalidades del interruptor Ponga el interruptor de tiempo ON TIME al fondo del detector en la posición de prueba TEST y DualBrite a apagado OFF Para PRUEBA TEST 1 5 20 ON TIME Off 3 6 Dusk to DualBrite Si se confunde mientras cambia de fases apague la electricidad por un minuto y préndala de nuevo Después del tiempo de calibración el control estará en fase AUTO MAT...

Page 6: ...es de la caja de empalmes con losalambresdelcontroldeluz Unalosyasegúrelos con un conector de alambre CUIDADO Para evitar los peligros de incendio o quemazón Deje que el elemento se enfríe antes de tocarlo La bombilla y el elemento funcionan a altas temperatu ras Mantenga al elemento por lo menos a 51 mm de los materiales combustibles No lo apunte hacia objetos que estén más cerca de 1 m Cambie só...

Page 7: ...idamente de temperatura tales como ductos de calefacción y acondiciona dores de aire Estas fuentes de calor pueden causar falsas alarmas Areas donde animales domésticos o el tráfico puedan activar el control Los objetos grandes cercanos y de colores res plandecientes que reflejan la luz del día pueden hacer que el detector se apague No apunte otras luces hacia el detector Alcance Máximo Angulo de ...

Page 8: ...lés para pedir ayuda antes de devolver el producto a la tienda Si tiene algún problema siga esta guía Usted puede también visitar nuestro sitio Web www hzsupport com Si el problema continúa llame al 1 800 858 8501 sólo para hablar en inglés de 7 30 AM a 4 30 PM CST L V Usted puede también escribir a HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Servicio Técnico Si se...

Page 9: ...is à nouveau en circuit Placer l interrupteur ON TIME à 1 5 ou 20 minutes Mettre l interrupteur hors circuit pendant une seconde puis le remettre en circuit Si vous ne savez plus dans quel mode se trouve l appareil couper l alimentation pendant une minute puis la rétablir Après le temps d étalonnage la commande reviendra au mode AUTO Minuterie DualBrite La lumière s allume à mi intensité pour le t...

Page 10: ...e Pourfaciliterl installation choisirunappareild éclairage devant être remplacé et qui est déjà commandé par un interrupteur MONTER HORIZONTALEMENT Installation et remplacement de l ampoule Avant de remplacer l ampoule couper l alimenta tion et laisser refroidir le luminaire blanc blanc Raccorder le s fil s de terre du luminaire et la vis de terre de la plaque de garde au fil de terre de la boîte ...

Page 11: ...ns Une trop grande sensibilité pourrait cau ser des déclenchements intempestifs Pour une couvertureaccrue utiliser l amplification de portée Range Boost Fixer la tête du détecteur en position en serrant la vis de blocage Éviter de trop serrer la vis Placer l interrupteur ON TIME à 1 5 ou 20 minutes Réglerl interrupteurDualBrite autempsd allumage désiré à faible intensité après le crépuscule 3h 6h ...

Page 12: ...ment pour obtenir de l aide avant de retourner l article au magasin En cas de problème suivez ce guide Vous pouvez aussi visiter notre site Web à www hzsupport com Si le problème per siste composez le 1 800 858 8501 service en anglais seulement entre 7 h 30 et 16 h 30 HNC du lundi au vendredi Vous pouvez aussi écrire au HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service S...

Reviews: