The detector is less sensitive to motion
directly towards it.
Sensor
Motion
Motion
Avoid aiming the control at:
• Pools of water or objects that change
temperature rapidly, such as heating
vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger
the control.
• Nearby large, light-colored objects re-
flecting daylight may trigger the shut-off
feature. Do not point other lights at the
sensor.
6 ft.
30 ft.
Maximum
Maximum
Range
Coverage Angle
150
°
Least Sensitive
Most Sensitive
❒
Walk through the coverage area noting
where you are when the lights turn on.
Rotate the sensor head (maximum 0f
45
°
left or right) to change the coverage
area.
TESTING
❒
Turn on the circuit breaker and light
switch. There is a one minute warm-up
before the sensor will detect motion prop-
erly.
❒
Switch the on-time to TEST position
and Dual Brite™ switch to the off posi-
tion.
Adding Decorative Tail
2. Screw
in exten-
sion bar.
1. Remove
decorative nut
from bottom of
fixture.
3. Add tail
piece and
trim.
4. Screw
decorative
nut back on.
TEST 1 5 10 MIN
OFF 3 6 DUSK TO
HOUR
DAWN
SPECIFICATIONS
Range . . . . . . . . . . . Up to 30 feet (varies during
daylight hours).
Sensing Angle . . . . . Up to 150
°
, 240
°
aimable
Electrical Load . . . . . (3) 60 W. candelabra,
400W (3.3 A.) total
Power Requirements 120 VAC, 60 Hz
Operating Modes . . . TEST, AUTO and
MANUAL OVERRIDE
Time Delay . . . . . . . 1 , 5, 10 minutes
Accent timer . . . . . . Off, 3, 6 Hrs, to dawn
Sensitivity . . . . . . . . Adjustable
The Heath Company reserves the right to discontinue
products and to change specifications at any time
without incurring any obligation to incorporate new
features in products previously sold.
❒
Set the amount of TIME you want the
light to stay on after motion is detected.
TEST 1 5 10 MIN
OFF 3 6 DUSK TO
HOUR
DAWN
❒
Set the amount of time after dusk you
want the lights on accent level.
240
°
Maximum Sensor
Rotatation
45
°
Maximum Aiming
Range
45
°
90
°
Get user manuals: