Heateflex SX-36-3V-P510 Instruction Manual Download Page 10

  

 

 

10 

405 E. Santa Clara St., Arcadia, CA 91006-7218 

O

: (626) 599-8566 

 

F

: (626) 599-9567 

 

  Do not use metal tools around the connectors when there is power to the unit, as they may 

cause arcing. 

  Turn off power before connecting alligator clips to any circuit. 

  Do  not  take  anything  for  granted  when  working  with  inexperienced  help.    Check  every 

operation before they perform it. 

  The operation of this unit creates large amounts of heated process fluid.  This fluid is likely to 

be  heated  to  temperatures  above  the  threshold  of  safety  for  human  contact.    Please  be 
advised  of  this  and  take  the  necessary  precautions  whenever  connecting  or  disconnecting 
any  plumbing  from  the  system.    If  you  are  ever  in  doubt,  turn  the  unit  off,  and  wait  an 
appropriate  amount  of  time  before  performing  any  operations  or  service  involving  the 
plumbing. 

  The process fluid within this system may also become pressurized from outside flow sources.  

It  is  the  user’s  responsibility  to  verify  that  pressure  within  the  system  has  been  relieved 
externally, in order to prevent exposure to hazardous fluid such heated de-ionized water, or 
heated acids. 

  This unit has several safety interlocks integrated within the system.  However, it is the use

r’s 

responsibility to verify that incoming power has been disconnected from a remote source prior 
to opening or servicing the unit.  This is advised to prevent user exposure to high voltage and 
current, and reduce the risk of electric shock. 

 

  This function of this unit is to heat process fluid for use in ultra-pure operations.  Therefore 

during  normal  operation  unit  will  become  heated  within  the  plumbing  and  the  heater 
compartment.  It is our recommendation that the unit is allowed a sufficient amount of time to 
cool  before  any  maintenance  or  inspections  are  made  to  the  unit  in  order  to  prevent  user 
exposure to heated surfaces or air. 

 

The processes in which this unit is used involve heated fluids.  Whenever heated fluids are 
involved, certain precautions must be taken in order to avoid user injury.  This is especially 
important since it is highly likely that this unit will be used with aggressive fluids which can 
further  harm  or  injure  an  individual,  such  as  de-ionized  water  and  process  acids.    User 
exposure to these types of materials can result in burning, scalding, and in some cases deep 
tissue  damage.    To  avoid  injury  it  is  the  user’s  responsibility  to  take  the  appropriate 
precautions as outlined above, and in all cases dealing with heated or aggressive materials, 
to use the appropriate safety equipment, such as but not limited to safety goggles and glasses, 
and chemically resistant gloves and garments.

 

Summary of Contents for SX-36-3V-P510

Page 1: ...rld Leader in Ultra Pure Heating www heateflex com 405 E Santa Clara St Arcadia CA 91006 7218 O 626 599 8566 F 626 599 9567 HEATEFLEX CORPORATION SX 36 3V P510 STAINLESS STEEL HEATER INSTRUCTION MANUA...

Page 2: ...405 E Santa Clara St Arcadia CA 91006 7218 O 626 599 8566 F 626 599 9567...

Page 3: ...ntroduction Description Equipment Specifications Environmental Specifications Basic Safety Precautions Installation Procedures Operating Instructions Quality Control Sheet Suggested Spare Parts List W...

Page 4: ...NG INSTRUCTIONS 5 RECEIVING INSPECTION PROCEDURE 5 INTRODUCTION 6 DESCRIPTION 6 EQUIPMENT SPECIFICATIONS 7 ENVIRONMENTAL SPECIFICATIONS 8 BASIC SAFETY PRECAUTIONS 9 INSTALLATION PROCEDURES 11 OPERATIN...

Page 5: ...FACTORY THEREFORE WHEN IT IS DELIVERED TO THE CARRIER IT BECOMES YOUR PROPERTY THUS IT IS IMPORTANT THAT YOU TAKE NOTE OF ANY DAMAGE WHETHER OBVIOUS OR HIDDEN REPORT THIS INFORMATION TO THE TRANSPORT...

Page 6: ...ultra high purity environment It is a high tech piece of equipment incorporating many design innovations and precautionary measures to insure safe and reliable operation under normal conditions This...

Page 7: ...oltage 480 VAC Hertz 60 Hz Number of phases 3 phase Current per phase 43 Amps Phase Inlet Connector 2 1 2 Sanitary Ferrule Outlet Connector 2 1 2 Sanitary Ferrule Drain Port 1 2 Sanitary Ferrule Press...

Page 8: ...Maximum fluid temperature 95 C Temperature resolution 1 C Maximum operating altitude 6 600feet 2 000meters Ambient temperature range 5 C 40 C operating 40 C 60 C storage Maximum relative humidity 80 u...

Page 9: ...mponents can develop temperatures that produce an auto ignition source Avoid mounting heaters in atmospheres containing combustible gases vapor or dust Article 501 of the National Electrical Code NEC...

Page 10: ...ibility to verify that incoming power has been disconnected from a remote source prior to opening or servicing the unit This is advised to prevent user exposure to high voltage and current and reduce...

Page 11: ...the left side of the cabinet For the types of fittings included refer to the Equipment Specifications on page 5 Once the appropriate plumbing has been connected water should be run through the system...

Page 12: ...set point to the required temperature This is accomplished by the following Refer to the temperature controls panel Verify that it is displaying the process temperature in the proper units If it is n...

Page 13: ...ic Due to the manner in which this unit operates it does not require regular re calibration or maintenance The only sort of calibration that is required is the Auto Tuning process This process is used...

Page 14: ...33 ALS 0 0 34 F41 ES1 5 35 F41 EHo1 0 36 F41 E1L1 0 37 F41 EH1 2 0 38 F41 EVT1 0 0 39 F41 Eeo1 0 40 F42 ES2 0 41 F42 Eho2 0 42 F42 E1L2 0 43 F42 EH2 2 44 F42 EVT2 0 0 45 F42 EEo2 0 Function Symbol Set...

Page 15: ...F52 dcAJ 1 00 118 F53 Ydb 2 0 119 F53 YHS 1 120 F53 Ybr 0 121 F53 PoS AdJ 122 F53 moT 10 123 F53 oLA 150 0 124 F53 VAL 0 125 F54 STS 0 126 F54 STPK 1 00 127 F54 ST1K 1 00 128 F54 STdK 1 00 129 F55 CH...

Page 16: ...er 2A 480VAC 2 Poles 11 1 309810 Transformer 380 480VAC 120V 24V 12V 12 1 300377 Contactor 3P 24VAC 50 60Hz 13 4 300108 Relay DPDT 24VAC DC Coil 14 4 300107 Relay SPDT 24VAC DC Coil 15 1 301010 Fuse G...

Page 17: ...in workmanship or material which may develop under normal handling and proper usage during a period of one year from the date of shipment or by its option to repair or replace the defective equipment...

Reviews: