Heat & Glo • TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Installation Manual • 2461-980 Rev. Q • 11/20
46
10
10
Finishing
A. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or finishing materials must not interfere
with air flow through louvers, operation of louvers or
decorative fronts, or access for service.
• Facing and/or finishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite and will
interfere with proper operation of decorative fronts and
louvers.
Figure 10.1 Non-combustible Facing Diagram
0 in.
NON-COMBUSTIBLE
BOARD
A
B
COMBUSTIBLE MATERIAL
0 IN.
0 IN.
MODEL
A
B
in.
mm
in.
mm
TRUE-36-IFT
61
1549
57-5/8
1464
TRUE-42-IFT
67
1702
62-5/8
1591
TRUE-50-IFT
75
1905
66-5/8
1692
NOTICE: Surface temperatures around the appliance will