background image

15

Figure 4.1  Chimney & Termination Cap Cleaning

 WARNING! 

Risk of Fire! 

Ignited creosote is extremely 

HOT. Prevent creosote buildup.

B. Creosote (Chimney) Cleaning

 Frequency: 

As needed; at least annually before light-

ing, or once every two months during heating season. 

When creosote has accumulated it shall be removed 

to reduce the risk of a chimney fire.

 By: 

Chimney Sweep

 Tools 

Needed: Brush, Phillips screwdriver

•  When  wood  is  burned  slowly,  it  produces  tar  and 

other organic vapors, which combine with expelled 

moisture  to  form  creosote.  The  creosote  vapors 

condense  in  the  relatively  cool  chimney  flue  of  a 

slow-burnign  fire. As  a  result,  creosote  residue 

accumulates  on  the  flue  lining.  When  ignited,  this 

creosote makes an extremely hot fire.

•  Remove all ash from the firebox and extinguish all 

hot embers before disposal. Allow the fireplace to 

cool completely.

•  Remove the top of the termination cap as shown in 

Figure 4.1 to clean the cap and chimney.

•  The creosote or soot should be removed from the 

chimney with a brush specifically designed for the 

size of chimney in use. 

•  Reinstall termination cap.

•  Clean out fallen debris from the firebox. 

Heat & Glo • Exclaim-36/42 Owner’s Manual • 4013-267 • Rev E • 05/07/14

Chimney

Remove 4 screws

and lift top pan off.

Cap

Slip

Section

ST1175

ST475

Square Termination Cap

Cap

Remove screws,

lift top cover.

Top Cover

TR11/TR11T

TR444/TR442

Round Termination Cap

TCT1175

Terra Cotta

Termination Cap

Available US only

Remove 2 screws from

the front and back and

lift the top off.

1. REMOVE (8) SCREWS

2. LIFT TOP             

TOP

TOP

SCREW

SCREW

DT SERIES

Summary of Contents for EXCLAIM-36

Page 1: ...t followed exactly a fire or explosion may result causing property damage personal injury or death Owner s Manual Operation and Care WARNING HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert c...

Page 2: ...serts 6 3 Important Safety and Operating Information A Fireplace Safety 7 1 Clear Space 7 2 Grate 8 3 Refractory 8 4 Firescreen 8 5 Flue Damper 8 6 Glass Doors 8 7 Over Firing Your Fireplace 8 8 Chimney Fire 8 B General Operating Parts 9 1 Flue Damper 10 2 Outside Air 10 3 Glass Doors 10 C Fuel 11 1 Hardwood vs Softwood 11 2 Moisture content 11 3 Seasoning 12 4 Storing Wood 12 5 Burning Process 12...

Page 3: ...s Manual Pay special attention to all Cautions and Warnings This Owner s Manual should be retained for future refer ence We suggest that you keep it with your other impor tant documents and product manuals Your new Heat Glo wood burning fireplace will give you years of durable use and trouble free enjoyment Wel come to the Heat Glo family of fireplace products Heat Glo is a registered trademark of...

Page 4: ...f first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for covered components is produced in the following tabl...

Page 5: ...g Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated surfaces from the use of ab...

Page 6: ... 267 Rev E 05 07 14 This fireplace may be installed in sleeping rooms EX CEPT in manufactured homes If installed with a gas log set provisions for the National Fuel Gas Code must be met This fireplace has been tested and listed for use with the optional components specified in this manual These op tional components may be purchased separately and in stalled at a later date Installation of an outsi...

Page 7: ...s Improper installation adjustment alteration service or maintenance can cause injury or property damage 1 Clear Space Combustible materials must not be stored on the hearth extension Room furnishings such as drapes curtains chairs or other combustibles must be at least 4 ft 1219 mm from the front of the fireplace Combustible materials are materials made of or sur faced with any of the following m...

Page 8: ...one approved by HHT Warning Risk of Fire Use only the factory sup plied integral grate Keeps logs in place Allows proper air circulation around the fire 3 Refractory The refractory is supplied to contain heat and provide an attractive interior It will break down over time and will need occasional replacement Small hairline cracks and discoloration are normal and do not affect its safety Warning Ri...

Page 9: ...children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away HOT SURFACES Glass and other surfaces are hot during operation AND cool down Figure 3 2 General Operating Parts CAUTION If you expect that...

Page 10: ...ULLY OPEN CORRECT PARTLY CLOSED INCORRECT PARTLY OPEN INCORRECT FULLY CLOSED CORRECT Figure 3 3 Operating Positions of Bi fold Doors Refer to Figure 3 2 for location and operation of control The outside air kit supplies some combustion air for your fireplace It may help reduce the effects of nega tive air pressure Close the inlet to prevent cold drafts when the fireplace is not being used 2 Outsid...

Page 11: ...you can use the softwood for starting the fire giv ing off quick heat to bring the fireplace up to operating temperature Add the hardwood for slow even heat and longer burn time 2 Moisture content The majority of the problems fireplace owners expe rience are caused by trying to burn wet unseasoned wood Freshly cut wood can be as much water as it is wood having a moisture content of around 50 Imag ...

Page 12: ...20 The time it takes to season wood varies from around nine months for soft woods to as long as eighteen months for hardwoods The key to seasoning wood is to be sure it has been split exposing the wet interior and increasing the surface area of each piece A tree that was cut down a year ago and not split is likely to have almost as high a moisture content now as it did when it was cut To season wo...

Page 13: ... You may notice an in dustrial odor the first few fires This is considered normal Use well seasoned wood Open the flue damper to a fully open position Place crumpled or twisted paper under the fireplace grate Loosely arrange kindling or small pieces of wood to form a tent on the fireplace grate Pre warm the flue to establish a draft to help reduce smoke spillage during start up Hold a rolled up pi...

Page 14: ...ey Sweep Confirm that termination cap remains clear and unobstructed Inspect for blockages such as bird nests leaves etc Inspect for corrosion or separation Inspect for creosote and remove as needed at least every two months during the heating season Inspect the system at the fireplace connection and at the chimney top In the event of a chimney fire Hearth Home Tech nologies recommends replacement...

Page 15: ...When ignited this creosote makes an extremely hot fire Remove all ash from the firebox and extinguish all hot embers before disposal Allow the fireplace to cool completely Remove the top of the termination cap as shown in Figure 4 1 to clean the cap and chimney The creosote or soot should be removed from the chimney with a brush specifically designed for the size of chimney in use Reinstall termin...

Page 16: ...und well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled D Glass Cleaning Frequency As necessary By Homeowner Tools Needed Vinegar or glass cleaner soft towel Clean glass with a non abrasive glass cleaner Use a damp cloth ...

Page 17: ...ection Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to starting fire section Flue blockage such as birds nests or leaves in termination cap Have chimney inspected for creosote and cleaned by a certified chimney sweep Down draft or negative pressure Competition with exhaust devices Do not use exhaust fans during start up refer to negative...

Page 18: ...sing an exterior factory built chim ney or exterior masonry chimney Try holding a burning rolled up newspaper as close to the flue outlet as pos sible for a few minutes then light the paper under the kindling The heat generated from the burning rolled up newspaper should help get the draft established Still other factors can affect how well your flue system performs Neighboring structures high win...

Page 19: ...p Outside air closed Overhead fan operating Overhanging tree Bird s nest or leaves in termination cap Structural changes in chimney area Creosote buildup in flue Strong win d s a r o u nd chimney termination Unsealed can lights Combustion air control Figure 5 1 Factory built Fireplaces Troubleshooting Heat Glo Exclaim 36 42 Owner s Manual 4013 267 Rev E 05 07 14 ...

Page 20: ...creen Cover top only Qty 2 req 31319 Side Trim Qty 2 req 31326 Strip Protector Qty 2 req 18320 Powder Coat Touch Up Paint 71479 Additional service parts on following page 4 14 36 Woodburning Fireplace 1 3 9 10 2 4 5 6 7 8 Service Parts EXCLAIM 36H EXCLAIM 36T Beginning Manufacturing Date Feb 2004 Ending Manufacturing Date Active IMPORTANT THIS IS DATED INFORMATION Parts must be ordered from a deal...

Page 21: ...y 2 req 18320 Side Trim Qty 2 req 31326 Powder Coat Touch Up Paint 71479 Additional service parts on following page 8 13 42 Woodburning Fireplace 1 2 3 9 10 4 5 6 7 8 Service Parts EXCLAIM 42H EXCLAIM 42T Beginning Manufacturing Date Feb 2004 Ending Manufacturing Date Active IMPORTANT THIS IS DATED INFORMATION Parts must be ordered from a dealer or distributor Hearth and Home Technologies does not...

Page 22: ...rs Bi fold clear view polished brass DM6036S DM8042S Glass doors Bi fold clear view stainless steel Bi fold Glass Doors See your Heat Glo dealer for a complete listing of optional components Gas Inserts Gas Log Sets Gas Log Lighters Wood burning Inserts Heat Glo Exclaim 36 42 Owner s Manual 4013 267 Rev E 05 07 14 ...

Page 23: ...23 This page intentionally left blank Heat Glo Exclaim 36 42 Owner s Manual 4013 267 Rev E 05 07 14 ...

Page 24: ...743 6019099 6048195 6053165 6145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302 6688302B2 6715724B2 6729551 6736133 6748940 6748942 6769426 6774802 6796302 6840261 6848441 6863064 6866205 6869278 6875012 6880275 6908039 6919884 7047962 7216645 D320652 D445174 D462436 Canada 1297749 2195264 2225408 2313972 Australia 780250 780403 1418504 or other ...

Reviews: