65
Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. W • 8/14
Figure 14.5 Air Shutter
Figure 14.4 Fixed Glass Assembly
H. Fixed Glass Assembly
WARNING! Risk of Asphyxiation!
Handle
fi
xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
•
DO NOT
strike, slam or scratch glass.
•
DO NOT
operate
fi
replace with glass removed, cracked,
broken or scratched.
•
Replace as a complete assembly.
Removing Fixed Glass Assembly
• Pull the four glass assembly latches out of the groove on
the glass frame. Remove glass door from the appliance
(see Figure 14.4).
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance. Pull out and
latch the four glass assembly latches into the groove on
the glass frame.
Air Shutter Settings
I. Install Trim and/or Surround
• Install optional trim kits and/or surrounds using the
instructions included with the accessory.
• Use non-combustible materials to cover the gap between
the sheet rock and the appliance (when applicable to the
model).
GLASS
ASSEMBLY
LATCHES
(BOTH BOTTOM
AND TOP)
AIR SHUTTER
WING NUT
J. Air Shutter Setting
Air shutter settings should be adjusted by a quali
fi
ed ser-
vice technician at the time of installation. The air shutter is
set at the factory for minimum vertical vent run. Adjust air
shutter for longer vertical runs. See Figure 14.5.
• Loosen the wing nut.
• Move the air handle to the left to open the air shutter.
• Move the air handle to the right to close the air shutter.
• Tighten the wing nut.
NOTICE:
If sooting occurs, provide more air by opening
the air shutter.
NG
LP
6000
1/4 in.
3/4 in.
8000
1/4 in.
3/4 in.