9
3. Burner motor
comes on,
but the heater
won’t ignite.
• Fuel pressure or volume
• Air inlet damper adjustment
• Ignition electrode
• Electronic igniter
• Burner airflow switch
• Gas valve
• Use a low pressure gauge (0-15 inches of water column) with 1/8” NPT
inlet.
Install gauge in the pressure tap port located on the output side of the gas
valve. Run the heater
.
Adjust the pressure by turning the pressure adjusting
screw (located on the input side top of the gas valve) counter clockwise until
the gauge reads the proper manifold pressure. Refer to pipe sizing charts in
the Heat W
agonEngineering Guide. Heater requires 9-14” W
.C. inlet pressure.
Ensure proper purge procedure (see Fuel Supply Installation).
• Rough setting at 1/2 open. Minor adjustments from the rough settings can be
made to achieve a smooth sounding burner with no soot from the flue pipe.
Insert volt meter probes into pr and – terminals on the Honeywell
Flame Safeguard Control. Set the volt meter on DC volts and run the heater
.
Adjust the air damper until the volt meter reads the highest voltage between 2
and 5 volts.
• Clean with fine sandpaper
. Make sure it is free from buildup or cracks.
• T
urn of
f the gas valve, turn on the burner
. Use insulated pliers to hold the
ignition wire and short it to ground. Pull the wire away from ground slowly
.
A
rainbow colored arc should travel between the wire and the ground at a
distance of 3/8 of an inch for a duration of 4-5 seconds.
• The burner airflow switch (located above blue Honeywell safeguard control) will
not allow power to the flame safeguard control when it is open. Check the
tubes supplying air to the switch for any restrictions.
ONL
Y
AS
A
TEST
, wire
around the air switch. If this test solves the problem, adjust or replace the
switch (Midco Burner Only).
• If there is power at the flame safeguard control and no power out to the
solenoid valves, replace the flame safeguard control. Check for continuity
between the terminals on the solenoid valve coil. If no continuity
, replace gas
valve.
V
G
10
0
0
T
R
OUBLESHOO
T
ING
Sympt
om
P
os
sible
C
aus
es
P
os
sible
Solut
ion
s
Summary of Contents for VG1000
Page 18: ...WAYNE BURNER PARTS BREAKDOWN 18 ...
Page 20: ...20 WAYNE BURNER SERVICING ELECTRODE SETTING ...
Page 21: ...21 WAYNE BURNER SERVICING ...
Page 23: ...23 MIDCO BURNER VG1000 ...
Page 24: ...24 WAYNE BURNER Serial No M5659 Lower WAYNE BURNER Serial No M5895 Beyond ...
Page 25: ...MIDCO BURNER VG1000 25 ...
Page 26: ...26 CONTROL BOX MAIN CIRCUIT DIAGRAM CONTROL BOX WIRING DIAGRAM ...
Page 27: ...27 CONTROL BOX WIRING ...
Page 28: ...28 CONTROL BOX PARTS HWP210080 20 HWP 22211 Aux Contact 20 HWP 20582 ...