![Heat Wagon VG1000 Installation And Maintenance Manual Download Page 12](http://html.mh-extra.com/html/heat-wagon/vg1000/vg1000_installation-and-maintenance-manual_2116014012.webp)
8.
The burner
continues to
run, but the
fan cycles on
and of
f.
• Gas manifold pressure
• Fuel supply pressure and
volume
• Fan sensor
• Heater Control Unit (HCU)
• Use a low pressure gauge (0-15 inches of water column) with 1/8” NPT
inlet.
Install gauge in the pressure tap port located on the output side of the gas
valve. Run the heater
.
Adjust the pressure by turning the pressure adjusting
screw (located on the input side top of the gas valve) counter clockwise until
the gauge reads the proper manifold pressure. Refer to pipe sizing charts in
the Heat W
agon Engineering Guide. Heater requires 9-14” W
.C. inlet pressure.
• Use a low pressure gauge (0-15 inches of water column) with 1/8” NPT
inlet.
Install gauge in the pressure tap port located on the output side of the gas
valve. Run the heater
.
Adjust the pressure by turning the pressure adjusting
screw (located on the input side top of the gas valve) counter clockwise until
the gauge reads the proper manifold pressure. Refer to pipe sizing charts in
the Heat W
agon Engineering Guide. Heater requires 9-14” W
.C. inlet pressure.
• On the heater control unit (HCU) disconnect the wires from terminals X12 and
X13. Using an ohm meter
, check the resistance between the two wires for a
reading. Compare to Sensor Resistance Chart page 25. If the test falls out of
this range, replace fan sensor
.
• T
urn the 3-position main switch to the fan position. If the blower runs, check the
fan sensor
. If it is good, replace the HCU.
V
G
10
0
0
T
R
OUBLESHOO
T
ING
Sympt
om
P
os
sible
C
aus
es
P
os
sible
Solut
ion
s
12
Summary of Contents for VG1000
Page 18: ...WAYNE BURNER PARTS BREAKDOWN 18 ...
Page 20: ...20 WAYNE BURNER SERVICING ELECTRODE SETTING ...
Page 21: ...21 WAYNE BURNER SERVICING ...
Page 23: ...23 MIDCO BURNER VG1000 ...
Page 24: ...24 WAYNE BURNER Serial No M5659 Lower WAYNE BURNER Serial No M5895 Beyond ...
Page 25: ...MIDCO BURNER VG1000 25 ...
Page 26: ...26 CONTROL BOX MAIN CIRCUIT DIAGRAM CONTROL BOX WIRING DIAGRAM ...
Page 27: ...27 CONTROL BOX WIRING ...
Page 28: ...28 CONTROL BOX PARTS HWP210080 20 HWP 22211 Aux Contact 20 HWP 20582 ...