OPERATING INSTRUCTIONS
INSTALLATION
• When transporting, use both lifting eyes located on sides of heater.
• Place the unit on a level and non-combustible surface.
• Minimum clearances from combustible materials for indoor or outdoor installation on
combustible flooring:
- outlet, minimum 10 feet
- sides, minimum 3 feet
- top, minimum 3 feet
- flue pipe exhaust, gas discharge minimum 2 feet
• Manufacturer recommends a free zone of 5 feet around the unit and a minimum distance of 10
feet at the unit’s flue gas openings are to be maintained.
• If the unit is placed indoors, secure an adequate fresh air opening for the burner combustion air.
• The unit may not be installed and operated in premises where explosive or combustible fumes
or dust are present. Check the regulation of local authorities, when necessary.
• Make sure that neither the air inlet nor the air outlet is obstructed.
FUEL SUPPLY
• This heater will burn kerosene (#1 or #2), diesel fuel (#1 or #2), and heating fuel (#1 or #2). It is
highly recommended to use winterized fuel with ambient temperatures less than 20ºF and to
also install optional circulation or fuel tank heaters.
• The installation of this heater must comply with all applicable local codes
.
• Check and clean fuel filter (if necessary) on a weekly schedule.
ELECTRICAL
• Electric cable extensions must be connected based on the unit capacity and cable length.
• Connect unit to a power supply with a suitable appliance receptacle (15 Amp).
• Confirm voltage at heater connection (105V min.) to ensure proper operation.
EXHAUST FLUE PIPE
• The unit is to be connected to a flue pipe with adequate draft, to ensure the proper start and
operation of the unit. Refer to page 16.
• The flue pipe is to be made of non-combustible material and clearances from combustible
materials must be a minimum 8 inches (temperature of flue gases is approximately 410º F).
• The flue pipe and its installation must comply with the regulations and instructions given by
the local authorities.