SAFETY & CAUTION
• Instructions given in this manual and the applicable regulation of the local authorities
must be followed.
• The unit may be operated only by those persons who have been instructed in it’s use.
• The unit is to be installed and operated in such a way as to ensure safety of employees and
surroundings.
• Never cover the unit’s air openings.
• Always secure an adequate fresh air supply to the unit.
• Never stand in front of the discharge end of the heater.
• Do not introduce foreign objects into the unit.
• Do not expose the unit to direct water jets.
• All electric cables outside the unit are to be protected against damage.
• Always disconnect the unit from power supply when maintenance or service is being
performed.
•
IF NOT OPERATED WITHIN GUIDELINES OF THESE OPERATING INSTRUCTIONS
MANUFACTURER WILL NOT BE HELD RESPONSIBLE AND WARRANTY
WILL BECOME VOID
.
4
SPECIFICATIONS
Model No. VF400
Fuels:
#1 or #2 Kerosene, Diesel, Heating Fuel
Capacity:
400,000 BTU/HR
Blower:
2,100 CFM
1/2” SP
Electrical Rating:
120 Volts, 10 Amps
Fuel Consumption:
3 GPH Max
Remote Thermostat:
On/Off
Max. Discharge Temp.:
200ºF @ 0ºF Ambient
Duct Size:
12” Dia., 50 ft. max (straight), temp rating 300ºF min.
Weight (approximate):
400 lbs.
Fuel Supply:
Manifold Pressure (Fuel Pump) Burner Nozzle
110 psi
3 GPH x 80A