12
Revised 2013
ELECTRICAL SERVICE INFORMATION
HOT ROD CIRCUIT BOARD TEST
A standard 115 volt neon circuit tester can be used for these tests.
CHECKING FUSES
Remove the fuse from their housing units located on the front of the electrical box. If a visual inspection does not verify a blown
fuse check for continuity by using the meter to read across the two terminals of the fuse.
If the meter reading does not show continuity, replace the fuse.
CHECKING THE HOT ROD
With the power turned OFF, remove the red hot rod wires from Terminals 1 and 2. Using the meter, measure the resistance of
the rod by connecting the leads of the meter to the red wires.
The meter should read between 130-136 ohms. If the reading is out of this range, replace the hot rod.
CHECKING THE CIRCUIT BOARD
After the hot rod and both the fuses have passed the above testing procedures, the circuit board can be tested.
With all the wires shown in the example circuit board (above) properly connected and the power ON, use the meter to test the
voltage across Terminals 1 and 2. If there is no voltage being read, the board needs to be replaced.
ELECTRICAL REQUIREMENTS
All Models are 110 Volts, 10 Amps.
THIS UNIT SHOULD NOT BE OPERATED IF ROD TEMPERATURE EXCEEDS
300 DEGREES FAHRENHEIT. IF SMOKE OR FUMES ARE DETECTED, DISCONTINUE USE