15
For Direct Spark Ignition (DSI)
Appliance Requirements
This appliance requires that 110-120 VAC be wired to the
junction box included in the manual bag assembly. Maintain
correct polarity when wiring the junction box.
The junction box is installed by sliding one tab of the box
through the slot on the lower right side of the outer wrap
and driving a screw through the other tab into the pilot hole
on the outer wrap.
Optional Accessories
Optional remote control kits require that 110-120 VAC be
wired to the fireplace junction box.
Figure 11. Direct Spark Ignition (DSI) Wiring Diagram
Remote Wall Switch
Position the remote wall switch in the desired position on a
wall. Run a maximum of 25 feet (7.8 m) or less of 16 A.W.G.
minimum wire and connect it to the fireplace ON/OFF switch
pigtails.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.