13

Figure 9.   Gas Supply Line

• Insert insulation from the outside of the fireplace and

pack the insulation tightly to totally seal between the

pipe and the outer casing.

• At the gas line access hole the gap between the supply

piping and gas access hole can be plugged with non-

combustible insulation to prevent cold air infiltration.

Step 7.  The Gas Supply Line

NOTE: Have the gas supply line installed by a qualified

service technician in accordance with all building codes

.

NOTE: Before the first firing of the fireplace, the gas

supply line should be purged of any trapped air.
NOTE: Consult local building codes to properly size

the  gas  supply  line  leading  to  the  1/2  inch

(13 mm) hook-up at the unit.

This  gas  fireplace  is  designed  to  accept  a  1/2  inch

(13 mm) gas supply line.
To install the gas supply line:
• A listed 1/2 inch (13 mm) manual shut-off valve and a

listed flexible gas connector are connected to the 1/2

inch (13 mm) inlet of the control valve.

• Locate the gas line access hole in the outer casing of

the fireplace.

• The gas line may be run from either side of the fireplace

provided the hole in the outer wrap does not exceed 2” in

diameter and it does not penetrate the actual firebox.

• Open the fireplace lower grille, insert the gas supply line

through the gas line hole, and connect it to the shut-off

valve.

• When attaching the pipe, support the control so that the

lines are not bent or torn.

!

Step 8.   Gas Pressure Requirements

Pressure requirements for Heat-N-Glo gas fireplaces

are shown in the table below.

Pressure

Natural Gas

Propane

Minimum

5.0 inches

11.0 inches

Inlet Pressure

w.c.

w.c.

Maximum Inlet

14.0 inches

14.0 inches

Gas Pressure

w.c.

w.c.

Manifold

3.5 inches

10.0 inches

Pressure

w.c.

w.c.

A one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping is

provided on the inlet and outlet side of the gas control for a

test gauge connection to measure the manifold pressure.
The  fireplace  and  its  individual  shut-off  valve  must  be

disconnected from the gas supply piping system during

any pressure testing of the system at test pressures in

excess of one-half (1/2) psig (3.5 kPa).
The fireplace must be isolated from the gas supply piping

system by closing its individual shut-off valve during any

pressure testing of the gas supply piping system at test

pressures equal to or less than one-half (1/2) psig (3.5 kPa).

• After the gas line installation is complete, use a soap

solution to carefully check all gas connections for leaks.

WARNING: DO NOT USE AN OPEN FLAME

TO CHECK FOR GAS LEAKS

.

STANDING PILOT

Figure 8.  Gas Control Systems

DSI IGNITION

1/4" (6mm)

CERAMIC

INSULATOR

1/2” (13mm)

IGNITOR

USE A WRENCH ON 

SHUT-OFF VALVE WHEN 

TIGHTENING GAS LINE

GAS VALVE 

FLEX

CONNECTOR

MANUAL

SHUT-OFF VALVE 

Summary of Contents for SL-350TV

Page 1: ...derwriters Laboratories Listed 541 985C 4 00 READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE Please contact your H...

Page 2: ...he installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Firepla...

Page 3: ...m 11 A Vent System Approvals 11 B System Components 11 C Bedroom Installation in Canada 12 D Vent Termination 12 Step 5 Positioning Leveling and Securing the Fireplace 12 Step 6 The Gas Control System...

Page 4: ...urrent edition The Uniform Mechanical Code current edition and local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space This model natural gas and...

Page 5: ...ailure to follow these instructions will void the owner s warranty and may present a fire hazard The Heat N Glo Warranty will be voided by and Heat N Glo disclaims any responsibility for the following...

Page 6: ...837mm 30 1 2 775mm 2 1 4 57mm 5 3 8 138mm GAS LINE ACCESS 11 3 8 288mm 1 2 13mm 4 101mm B VENT 8 1 2 216mm 16 1 4 414mm 15 3 4 400mm 22 5 8 575mm ELECTRICAL ACCESS TOP STANDOFFS HOOD VENT COLLARS ELEC...

Page 7: ...l is 1 2 inch 13mm A 34 B 31 C 16 1 4 Figure 3 Framing Dimensions The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the combustible construct...

Page 8: ...e is located It is recommended that all natural venting non air tight gas fireplaces have outside air connected to them It is also recommended that the building be mechanically or passively balanced t...

Page 9: ...inside the unit to check that the vent pipe is attached NOTE It is always better to first attach a straight section of vent to the unit before attaching an elbow Avoid using elbows in the vent system...

Page 10: ...Fireplace To properly position level and secure the fireplace Place the fireplace into position see Figure 7 Level the fireplace from side to side and from front to back Shim the fireplace with non co...

Page 11: ...line through the gas line hole and connect it to the shut off valve When attaching the pipe support the control so that the lines are not bent or torn Step 8 Gas Pressure Requirements Pressure require...

Page 12: ...ts require that 110 120 VAC be wired to the factory installed junction box before the fireplace is per manently installed Figure 10 Standing Pilot Ignition Wiring Diagram NOTE THIS UNIT IS NOT APPROVE...

Page 13: ...b into the pilot hole on the outer wrap Optional Accessories Optional remote control kits require that 110 120 VAC be wired to the fireplace junction box Figure 11 Direct Spark Ignition DSI Wiring Dia...

Page 14: ...ce but MUST NEVER overlap onto the front face The joints between the finished wall and the fireplace top and sides can only be sealed with a 300 F 149 C minimum sealant WARNING WHEN FINISHING THE FIRE...

Page 15: ...run for 8 hours on the initial start up This will help to cure the chemicals used in the paint and logs Subsequent lightings of the fireplace will not require this purging of air from the gas supply...

Page 16: ...annually By Qualified service technician Task Brush or vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically B...