background image

1

- Do not store or  use gasoline or other flam-

mable vapors and liquids in the vicinity of this

or any other appliance.

-

What to do if you smell gas

• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's

instructions.

• If you cannot reach your gas supplier, call

the fire department.

- Installation and service must be performed by a

qualified installer, service agency, or the gas

supplier.

Model:

SL-350TV

Installers Guide

WARNING:  IMPROPER  INSTALLA-

TION, ADJUSTMENT, ALTERATION,

SERVICE  OR  MAINTENANCE  CAN

CAUSE INJURY OR PROPERTY DAM-

AGE. REFER TO THIS MANUAL. FOR

ASSISTANCE OR ADDITIONAL INFOR-

MATION  CONSULT A  QUALIFIED  IN-

STALLER, SERVICE AGENCY, OR THE

GAS SUPPLIER.

Underwriters

Laboratories Listed

541-985C  4/00

READ THIS MANUAL BEFORE INSTALLING OR

OPERATING THIS APPLIANCE. THIS 

INSTALLERS

GUIDE 

MUST BE LEFT WITH APPLIANCE FOR

FUTURE REFERENCE.

Please  contact  your  Heat-N-Glo  dealer  for  any

questions  or  concerns.  For  the  number  of  your

nearest Heat-N-Glo dealer, please call 952-985-6000.

Printed in U.S.A.   Copyright 2000,
Heat-N-Glo, a division of Hearth Technologies Inc.

20802 Kensington Boulevard, Lakeville, MN 55044

WARNING: IF THE INFORMATION

IN THESE INSTRUCTIONS IS NOT

FOLLOWED EXACTLY, A FIRE OR

EXPLOSION MAY RESULT CAUS-

ING PROPERTY DAMAGE, PER-

SONAL INJURY, OR DEATH.

This  product  is  covered  by  one  or  more  of  the  following  patents:  (United  States)  4,112,913;  4,408,594;  4,422,426;  4,424,792;  4,520,791;  4,793,322;

4,852,548;  4,875,464;  5,000,162;  5,016,609;  5,076,254  5,191,877;  5,218,953;  5,328,356;  5,429,495;  5,452,708;  5,542,407;  5,613,487;  (Australia)

543790;  586383;  (Canada)  1,123,296;  1,297,746;  2,195,264;  (Mexico)  97-0457;  (New  Zealand)  200265;  or  other  U.S.  and  foreign  patents  pending.

Summary of Contents for SL-350TV

Page 1: ...derwriters Laboratories Listed 541 985C 4 00 READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE Please contact your H...

Page 2: ...he installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Firepla...

Page 3: ...m 11 A Vent System Approvals 11 B System Components 11 C Bedroom Installation in Canada 12 D Vent Termination 12 Step 5 Positioning Leveling and Securing the Fireplace 12 Step 6 The Gas Control System...

Page 4: ...urrent edition The Uniform Mechanical Code current edition and local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space This model natural gas and...

Page 5: ...ailure to follow these instructions will void the owner s warranty and may present a fire hazard The Heat N Glo Warranty will be voided by and Heat N Glo disclaims any responsibility for the following...

Page 6: ...837mm 30 1 2 775mm 2 1 4 57mm 5 3 8 138mm GAS LINE ACCESS 11 3 8 288mm 1 2 13mm 4 101mm B VENT 8 1 2 216mm 16 1 4 414mm 15 3 4 400mm 22 5 8 575mm ELECTRICAL ACCESS TOP STANDOFFS HOOD VENT COLLARS ELEC...

Page 7: ...l is 1 2 inch 13mm A 34 B 31 C 16 1 4 Figure 3 Framing Dimensions The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the combustible construct...

Page 8: ...e is located It is recommended that all natural venting non air tight gas fireplaces have outside air connected to them It is also recommended that the building be mechanically or passively balanced t...

Page 9: ...inside the unit to check that the vent pipe is attached NOTE It is always better to first attach a straight section of vent to the unit before attaching an elbow Avoid using elbows in the vent system...

Page 10: ...Fireplace To properly position level and secure the fireplace Place the fireplace into position see Figure 7 Level the fireplace from side to side and from front to back Shim the fireplace with non co...

Page 11: ...line through the gas line hole and connect it to the shut off valve When attaching the pipe support the control so that the lines are not bent or torn Step 8 Gas Pressure Requirements Pressure require...

Page 12: ...ts require that 110 120 VAC be wired to the factory installed junction box before the fireplace is per manently installed Figure 10 Standing Pilot Ignition Wiring Diagram NOTE THIS UNIT IS NOT APPROVE...

Page 13: ...b into the pilot hole on the outer wrap Optional Accessories Optional remote control kits require that 110 120 VAC be wired to the fireplace junction box Figure 11 Direct Spark Ignition DSI Wiring Dia...

Page 14: ...ce but MUST NEVER overlap onto the front face The joints between the finished wall and the fireplace top and sides can only be sealed with a 300 F 149 C minimum sealant WARNING WHEN FINISHING THE FIRE...

Page 15: ...run for 8 hours on the initial start up This will help to cure the chemicals used in the paint and logs Subsequent lightings of the fireplace will not require this purging of air from the gas supply...

Page 16: ...annually By Qualified service technician Task Brush or vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically B...