Heat-N-Glo LifeStyle Collection • Dakota 42, Dakota 42H • 4036-905 Rev. F • 11/04
6
3
Framing and Clearances
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
•
Illustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design
preference.
WARNING
Fire Risk
Provide adequate clearance:
• Around air openings
• To combustibles
• For service access
Locate appliance away from traffic areas.
A. Selecting Appliance Location
When selecting a location for your appliance it is important
to consider the required clearances to walls (see Figure 3.1).
Figure 3.1 Framing Dimensions
A
B
C
D
E
F
G
Inches
24-3/4
24-1/8
48
49
5/8
1/2
1-1/2
Millimeters
629
613
1219
1245
16
13
38
NOTE: For actual appliance dimensions refer to Sec-
tion 13.
A
B
C
D
E
NOTE: IF THIS SURFACE IS INSIDE THE
BUILDING’S WARM AIR ENVELOPE...
...THEN THIS SURFACE MUST
BE AN EXTERIOR WALL SYSTEM.
F
F
G
CAUTION
Water infiltration and property damage risk.
• Do NOT infringe on building’s warm air envelope.
• If fireplace is installed into exterior wall of build-
ing, the surface surrounding it must be exterior
wall system.