Heat-N-Glo LifeStyle Collection • Dakota 42, Dakota 42H • 4036-905 Rev. F • 11/04
15
A. Mantel Projections
Figure 8.1 shows the minimum vertical dimension of
appliance mantels or other combustible projections above
the top front edge of the appliance.
Finishing
B. Facing Material
8
Figure 8.2 Noncombustible Facing Diagram
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
•
Modifying or covering grilles could cause
temperature rise and fire hazard.
WARNING
Finishing materials must not interfere with:
•
Air flow through grilles or louvers.
•
Operation of louvers or doors.
•
Access for service.
Fire Risk.
Finish all edges and fronts to clearances and
specifications listed in manual.
WARNING
•
Black metal appliance front may be covered with non-
combustible material only.
•
Do NOT overlap combustible materials onto
appliance front.
•
Install combustible materials up to specified clearanc-
es on top front and side edges.
•
Seal joints between the finished wall and appliance
top and sides using only a 300
o
F minimum sealant.
FINISH WALL MATERIAL MAY BE
COMBUSTIBLE - TOP AND SIDES
NON-COMBUSTIBLE
BOARD
SEALANT MATERIAL
0”
0”
0”
Figure 8.1 Clearances to Mantels or other Combustibles
above Appliance
84 INCHES
MINIMUM
*This appliance can be installed a minimum of 6 inches
from a combustible structure unless the structure is
vinyl which requires a minimum clearance of 48 inches.
Free standing installation