34
Figure 32. Standing Pilot Ignition Wiring Diagram
OPTIONAL WALL SWITCH
THERMOSTAT OR REMOTE
REMOTE SWITCH
PIGTAIL
OFF
ON
ON/OFF
SWITCH
THERMOPILE
TP/TH
TP
TH
GAS VALVE
THERMOCOUPLE
Step 8. Wiring the Fireplace
NOTE: Electrical wiring must be installed by a compe-
tent electrician.
For Standing Pilot Ignition Wiring
Appliance Requirements
•
This appliance
DOES NOT
require 230 VAC to operate.
WARNING: DO NOT CONNECT 230 VAC TO THE
REMOTE WALL SWITCH OR THE CONTROL
VALVE WILL BE DESTROYED.
Optional Accessories
Optional fan and remote control kits require that 230 VAC
be wired to the factory installed junction box before the
stove is permanently installed.
!
Remote Wall Switch
Position the remote wall switch in the desired position on a
wall. Run a maximum of 7.8 m or less length of 1.02 mm
diameter minimum wire and connect it to the stove ON/OFF
switch pigtails.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
!
WARNING: WHEN FINISHING THE ST OVE,
NEVER OBSTRUCT OR MODIFY THE AIR INLET/
OUTLET GRILLES IN ANY MANNER.