Manufactured for
Heat
IQ
to give you years of reliable service, we guarantee it !
Assumes Advanced setting
A8
is set to five plus two
Thank you for purchasing this thermostat from heat IQ we appreciate your business
Programmable Touch screen
RF
thermostat
HIQ 414RF
and
415RF
Specifications
Power
-
2 x AA 1.5V batteries
Accuracy
- 0.5 Deg C
internal Sensor
- NTC(10K)1%
Load capacity
- 5A/240v (BW)
Switch type
- Switch relay
Range of adjustment
- 5 to 35 Degrees C
Range of display
- 0 to 40 Degrees C
Setting type
- 5 plus 2 days
Mounting
- Wall Surface mounted or free holder
(Can fit over standard box, fit Horizontal)
Dimensions
- 130 w 90 h 27 d
Output switching is Radio Frequency . reliever can switch
voltage up to 5
A
or, make potential free switching (typical
with most boilers or Heat pumps)
Mounting &Wiring instructions
Install approximately 1.5 m from floor
Avoid walls subject to direct sunlight or adjacent to a heat
source and install
away from drafts from doors and windows.
Seal around the opening into the wall space behind the
control if drafts present in cavity
Service Guarantee (2 years from date of purchase)
This product was manufactured to our exacting standards . In case of failure, no serviceable parts are enclosed, do not open ,return to
Trade
point
(
Heat
IQ
)
Ltd
Wanganui New Zealand [email protected] or call
0064 6 3447392
PO box 530 Wanganui
Advanced settings
:
By
Engineer Recommended
SET
PRG
-
+
Current temperature and set point
Day
Six daily set points
Auto
manual override
Setting mode
Time
Heating on
touch controls
Programmed memory is held when screen is off
Setting and use
To set clock time and day
Press PRG momentarily, use plus or minus to change flashing setting
press PRG again to move to next item.
before Setting switch times and temperatures we recommend you write down
each of the six time and temperatures required for the Mon-Fri and the Sat Sun
programmes. You will need to work quickly when entering to avoid the screen
returning to the default display
To set (6) Daily set points
(
Monday to Friday
)
Press and Hold PRG the first setting point time will flash set the hour
and press PRG to enter... now set the minutes value and press PRG to
enter .... Now set the desired temperature and press PRG to enter
.
You are now at the second set time
.. do as above and repeat until all
six times and setting temperatures are entered.
(Saturday & Sunday)
As you complete the sixth setting the process will start again for the
Saturday and Sunday setting
following the process as above enter your six weekend set points and
temperatures
.
You can
review all settings
by pressing and holding PRG to enter the
settings then simply repeat touch PRG to scroll through the settings
Manual override
Press SET to switch to manual the hand symbol will be displayed in this
mode use the +/- buttons to set your desired full time setting.
Temporary override
at any time you can use +/- to adjust the current set temperature the
setting will return to default at the next switching time
Key lock
Press + & - for five seconds to lock or release keys
Advanced Group 1 settings
with the thermostat in off
status press
SET
and
+
together for three to five
seconds...
A1
will be displayed you can scroll from
A1
to
A9
by
pressing
SET - To adjust parameters use
+
/
-
A1
=
temperature calibration, adjust current
temperature reading
A2
= stop start switching differential 1 to 5 C.
A3
=
Key lock , when used 0= locked except the on off
key 1= all keys will be locked
A4
=
High temp protection switch point 45 Deg
default, = System off if exceeded
(not really relevant to
normal household uses
A5
=
Low temperature protection = Auto system on
switch point 5 Deg C default .Range 5 to 10 DegC
A6
=
Low user setting limit -
Recommend 5 deg C
A7
= High user setting limit -
Recommend 25deg C
A8
= Programming type
7 Days
/
6 plus 1
or
5 plus 2
A9
= Checking Transceiver IP
Within 10 sec of power on
press + key quickly to check transceiver Address will be
displayed
For further assistance including more advanced
setting options contact Heat IQ
REPLACE BATTERIES ANUALY
Use
small screwdriver in slots in lower edge to
remove control from it's back plate
Requires 2 x AA batteries
See over for
RF