background image

 

13

 

HD02 01/10/11 

 

 

Summary of Contents for FW5C

Page 1: ...d operation of controls Important This product must be installed by a suitably qualified installer Heat Design 30 60 Hawthorn Road Western Industrial Estate Naas Road Dublin 12 www heatdesign ie PLEAS...

Page 2: ...Chimney 4 4 2 Ventilation 4 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 5 4 6 Fixing 5 4 7 Hearths 6 4 8 Commissioning Handover 6 5 Technical Data 6 6 Operating Instructions...

Page 3: ...front door Then remove the two side firebricks and the two rear firebricks Handle store very carefully to one side where they will not get broken 2 2 Now lift up the grate and carefully remove this f...

Page 4: ...lly regularly in use and especially after a period on disuse e g after summer Lift down the baffle at least weekly to check for build up of soot or debris on the top from the flue pipe Remove the baff...

Page 5: ...tilation is recommended however it is not required in England and Wales unless the appliance rated output is greater than 5kW Over 5kW 5 5 cm2 of ventilation 550mm2 is required for every kW output abo...

Page 6: ...clearance of 150mm will give a better heat output To conform with building regulations the fireplace recess walls should be at least 200mm thick or each rear leaf at least 100mm thick in the case of...

Page 7: ...be kept clear from obstruction Warning This appliance will be very hot when in operation and due care should be taken when operating the controls A leather glove is provided to assist safe operation D...

Page 8: ...use a wet cloth with some of the wood ash if burning wood but be very careful to use very clean ash so as not to scratch the glass Outer body The outer body simply needs to be dusted from time to time...

Page 9: ...ke emission DO NOT leave the stove unattended if the door is left ajar Allow the fuel to reach a steady glow and build the fire up gradually by adding a few small sticks or well split logs at a time O...

Page 10: ...ed the fire is in an over fire situation and the controls should be adjusted accordingly Never leave the stove unattended for long periods without first adjusting the controls to a reduced and safe se...

Page 11: ...10 HD02 01 10 11 Fig 3 FW5C Cassette Stove Dimensions...

Page 12: ...attends any stove problem that is not related to product failure 6 Where can I get spare parts Your local Firewarm Stove retailer will be pleased to supply spare parts and to provide any other informa...

Page 13: ...12 HD02 01 10 11 Heat Design 30 60 Hawthorn Road Western Industrial Estate Naas Road Dublin 12 T 01 408 9192 F 01 408 9193...

Page 14: ...13 HD02 01 10 11...

Reviews: