Packaged Thru-The-Wall Heat Pump
OWNER’S MANUAL
Heat Controller, Inc.
……………………………………………………………………………………………………………
3
ALL PERFORMANCE DATA AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
STANDARD TEST OPERATING CONDITIONS IN COOLING AND DEHUMIDIFICATION MODE
Inside 80°F DB; 67°F WB
Outside 90°F DB; 75°F WB
STANDARD TEST OPERATING CONDITIONS IN HEATING MODE
Outside 47°F DB; 43°F WB
Inside 68.0°F DB;
Model
RPHE-093G
Cooling capacity (Btu/h)
9300
Heating capacity (Btu/h)
9300
Electric heater capacity (Btu/h)
6800
Power input in cooling (W)
922
Power input in heating (W)
864
Power input for Electric heater (W)
2000
EER (Btu/W)
9.99
COP (Btu/Btu)
3.16
Air flow (ft
3
/m)
266
Fan speed setting
3+Auto
Dehumidification capacity *(gal/h)
0.217
Noise level indoor dB(A)
48.2
Noise level outdoor dB(A)
58.1
Power supply (V/Ph/Hz)
208/230/ 1 / 60
Refrigerant type
R410A
Refrigerant charged (lb)
1.43
Dimension HxWxD (in)
22.83 x 43.11 x 9.65
Weight (lb)
114.64
Inlet/Outlet hole diameter (in)
6.38
Fresh air pipe diameter (in)
1.97
1.6 TECHNICAL FEATURES (P1, P2)