TROUBLESHOOTING  TIPS

TROUBLESHOOTING

1. Unit does not
    Start when
    Pressing on/off
    Button

PROBLEM

POSSIBLE CAUSES

SUGGESTED REMEDIES

Reset the temperature.

Make sure all the windows and
doors are closed.

Remove the heat sources if possible.

Connect the duct and make
sure it can function properly.

Decrease the set temperature.

Clean the air filter.

-   Room temperature is lower than
    the set temperature.(Cooling mode)

-   The windows or doors in the room
    are not closed.

-   There are heat sources inside the 
    room.

-   Exhaust air duct is not connected or
    blocked.

-   Temperature setting is too high.

-   Air filter is blocked by dust.

2. Not cool enough

Place the unit on a flat, level
ground if possible.

It is normal.

-   The ground is not level or not flat 
    enough.

-   The sound comes from the flowing
    of the refrigerant inside the 
    air-conditioner.

4. Noisy or vibration

5. Gurgling  sound

Switch on again after the unit 

has cool down.

-  The automatic over heat 

   protection function. When the 

   temperature at the air outlet 

O

O

   exceed 70 C/158 F,th e  de vice 

      will st op.

6. Power shut off at
    Heating mode

-   P1 appears in the display window

Drain  the water in the bottom tray.

Summary of Contents for Comfort-Aire PS-101A

Page 1: ...h Ave Jackson MI 49203 517 787 2100 www heatcontroller com INSTALLATION OPERATION MAINTENANCE MANUAL Portable Room Air Conditioner PS 81A PS 101A PS 121A French version of this manual is available on...

Page 2: ...g 15 AIR CONDITIONER FEATURES CARE AND MAINTENANCE TROUBLESHOOTING TIPS OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS IDENTIFICATION OF PARTS SAFETY PRECAUTIONS Safety rules 3 Operating conditions...

Page 3: ...r to avoid electrical shock Do not remove any cover panels Never use this appliance if it is not working properly or if it has been dropped or damaged Never use the plug to start and stop the unit Alw...

Page 4: ...nces vapors in the vicinity of this or any other appliance To avoid fire hazard or electric shock do not use an extension cord or an adaptor plug Do not remove any prong from the power cord WARNING El...

Page 5: ...rizontal Louver Blade swings automatically Casters Carrying Handles both sides 1 2 3 4 1 2 3 4 Fig 1 Fig 2 Rear 9 6 7 8 10 11 6 7 8 9 10 11 Upper Air Filter Behind the grille Air Outlet Power cord out...

Page 6: ...sius To convert from one to the other press and hold the Up and Down buttons at the same time for 3 seconds 3 Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjunction with...

Page 7: ...tes It indicates that the Auto Start program is initiated Press or hold the UP or DOWN buttons to change the time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The con...

Page 8: ...fully Use the SWING button on the remote controller to stop the louver at a desired angle If the louver is placed in a position which would affect the cooling process of the air conditioner it will au...

Page 9: ...place any obstacles around the air inlet or outlet of the unit Allow 1ft 3ft 30cm to 100cm of space from the wall with for efficient air conditioning Fig 5 Your window slider kit has been designed to...

Page 10: ...h of window shorten the adjustable window kit if the width of window is less than 26 5 67 5 cm Open the window sash and place the window slider kit on the window stool Fig 9 3 Cut the foam seal adhesi...

Page 11: ...the adjustable window kit if the width of window is less than 26 5 67 5 cm Open the window sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the...

Page 12: ...pages for window kit installation 2 Insert the hook of the Exhaust hose into the hole seat of the air outlet and slide down the Exhaust hose along the arrow direction See Fig 17 for installation IMPOR...

Page 13: ...t floor Please refer to Fig 18 19 When the water level of the bottom tray reaches a predetermined level Carefully move the unit near a drain location remove the bottom drain plug and let the water dra...

Page 14: ...ce Installation Insert the upper air filter from upward after cleaning attach the lower air filter on the air inlet grille then reinstall the grille by using the screw 2 Unit cabinet Use a lint free d...

Page 15: ...doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocked by dust 2 Not cool enough Pl...

Page 16: ...04 2009 3 2013...

Reviews: