26
!
WARNING: DO NOT CONNECT 110-120 VAC
TO THE REMOTE WALL SWITCH OR THE
CONTROL VALVE WILL BE DESTROYED.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING ERRORS CAN
CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
Figure 24. Standing Pilot Ignition Wiring Diagram
!
Step 7
Wiring the
Stove
NOTE: Electrical wiring must be installed by a
competent electrician.
For Standing Pilot Ignition Wiring
Appliance Requirements
• This appliance DOES NOT require 110-120 VAC
to operate.
WARNING: DO NOT CONNECT 110-120
VAC TO THE GAS CONTROL VALVE OR
THE APPLIANCE WILL MALFUNCTION
AND THE VALVE WILL BE DESTROYED.
Optional Accessories
Optional fan and remote control kits require that 110-
120 VAC be wired to the factory installed junction
box before the stove is permanently installed.
Remote Wall Switch
Position the remote wall switch in the desired
position on a wall. Run a maximum of 25 feet (7.8m)
or less length of 18 A.W.G. minimum wire and
connect it to the stove ON/OFF switch pigtails.
Figure 25. Fan Wiring Diagram (when fitted)