Heat & Glo  •  TIARAP-BK-IPI, TIARAP-BR-IPI, TIARAP-CES-IPI Owner’s Manual   •  2344-981  •  5/14 

B. Troubleshooting

IntelliFire Plus™ Ignition System

Symptom

Possible Cause

Corrective Action

1. Pilot won’t light. 

The ignitor/module 
makes noise, but no 
spark.

A.  Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are 
connected to correct terminals on module and pilot assembly.

B.  Loose connections or electrical 

shorts in the wiring.

Verify no loose connections or electrical shorts in wiring from mod-
ule to pilot assembly. Verify connections underneath pilot assembly 
are tight; also verify igniter and 

fl

 ame sense wires are not grounding 

out to metal chassis, pilot burner, pilot enclosure, mesh screen if 
present, or any other metal object. 

C.  Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be 
approximately .17 in. or 1/8 in. (3 mm).

2. Pilot won’t light, 

there is no noise or 
spark.

A.  No power, transformer installed 

incorrectly, or depleted batteries.

Verify that transformer is installed and plugged into module. Check 
voltage of transformer at connection to module. Acceptable read-
ings of a good transformer are between 6.4 and 6.6 volts DC.  Bat-
tery power supply voltage must be at least 4 volts.  If less than 4 
volts, replace batteries.

B.  A shorted or loose connection in 

wiring con

fi

 guration or wiring har-

ness.

Remove and reinstall the wiring harness that plugs into module. 
Verify there is a tight 

fi

 t. Verify pilot assembly wiring to module. Re-

move and verify continuity of each wire in wiring harness.  Replace 
any damaged components.

C.  Improper wall switch wiring.

Verify that 110-120 VAC power is “ON” to junction box.

D.  Module not grounded.

Verify black ground wire from module wire harness is grounded to 
metal chassis of appliance.

3. Pilot sparks, but 

Pilot will not light.

A.  Gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet 
pressure reading is within acceptable limits.

B.  Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be 
approximately .17 in. or 1/8 in. (3 mm).

C.  Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

D.  Pilot valve solenoid. 

Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module.  
If below 1.5 volts, replace module.  If 1.5 volts or greater, replace 
valve.

Summary of Contents for TIARAP-BK-IPI

Page 1: ...ts for location of additional Commonwealth of Massachusetts requirements DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What to do if...

Page 2: ...Gaz Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Appr...

Page 3: ...rmation A Appliance Certification 6 B Glass Specifications Ceramic 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifi...

Page 4: ...te of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent autho...

Page 5: ...SED WARRANTY SPECIFIED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interi...

Page 6: ...NSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada 2 2 Product Specific Information B Glass Specifications Ceramic This appliance is equipped with 5 mm ceramic gl...

Page 7: ...children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Clothing furniture draperies and other flammable materials must not be placed on...

Page 8: ...RNING Risk of Fire or Asphyxiation DO NOT op erate fireplace with fixed glass assembly removed Figure 3 2 General Operating Parts GLASS ASSEMBLY SECTION 4 B FAN KIT SECTION 6 A CLEAR SPACE SECTION 3 A...

Page 9: ...loor WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 220 240 VAC TO THE...

Page 10: ...ion during fire place break in Some people may be sensitive to smoke and odors Smoke detectors may activate G Heat Management Heat Output This model has a variable burn rate which is controlled by the...

Page 11: ...control cavity of the appliance See Figure 3 3 for location 2 Locate the battery tray and insert four AA cell batteries Battery polarity must be correct or module damage will occur A complete wiring d...

Page 12: ...e RC300 remote control to operate your fireplace the appliance switch will override any commands given by the remote 5 Module Reset This module may lock out under certain conditions When this occurs t...

Page 13: ...by Glass Cleaning Seasonally Homeowner Remote Control Seasonally Venting Seasonally Gasket Seal and Glass Inspection Annually Qualified Service Technician Log Inspection Annually Firebox Inspection A...

Page 14: ...emote transmitters and battery powered receivers Place remote control out of reach of children If not using your fireplace for an extended period of time summer months vacations trips etc to prevent u...

Page 15: ...tion when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operat...

Page 16: ...e paint and the burning off of any oils remaining from manufacturing If appliance has not been used for some time dust can build up and cause an odor Film on the glass This is a normal result of the c...

Page 17: ...ltage of transformer at connection to module Acceptable read ings of a good transformer are between 6 4 and 6 6 volts DC Bat tery power supply voltage must be at least 4 volts If less than 4 volts rep...

Page 18: ...d to white sensor wire Polish flame sens ing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continuity with a multi meter with ohms set at lo...

Page 19: ...n is purchased have it installed by a qualified service technician Section 3 discusses using the fan to manage the heat output Follow the instruc tions supplied with the fan kit to operate your fan Se...

Page 20: ...ice Parts Beginning Manufacturing Date June 2014 Ending Manufacturing Date Active TIARAP IPI Part number list on following page Log Set Assembly Gas Stove DV 05 14 TIARAP CES IPI TIARAP BR IPI TIARAP...

Page 21: ...0010BK TIARAP BR 476 0010PBR TIARAP CES 476 0010CES 5 Side Left or Right TIARAP BK 476 0020BK TIARAP BR 476 0020PBR TIARAP CES 476 0020CES 6 Grommet 2118 420 7 Pilot Shield 2344 103 8 Pilot Assembly...

Page 22: ...s Provide model number and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 25 1 Blower Shroud Top 2344 118 25 2 Relie...

Page 23: ...consumers Provide model number and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 18 1 Battery Pack 2166 323 18 2 J...

Page 24: ...____________________________________________ ________________________________________________________________________________ __________________________________________________________________________...

Reviews: