background image

31

Heat & Glo  •  Tiara Petite B  •  7026-101 Rev. N  •  10/11  

8

Appliance Setup

A.  Remove Shipping Materials

Remove shipping materials from inside or underneath the 
fi rebox.

B.  Leg Leveling System

Figure 8.1

   Thread Allen bolts through nuts until fl ush.   The 

Allen bolts and nuts are included in the component pack inside 
the appliance fi rebox. 

Figure 8.2

   Slide assembled nuts and bolts into the slots on 

the legs with the nuts on the bottom.

Figure 8.3

   Use a 5/32 in. 4mm) Allen wrench to adjust legs 

up and down to desired level.

C.  Flue Restrictor Installation

Figure 8.4

   Installation of the fl ue restrictor requires the removal 

of the baffl e located inside the fi rebox.  Remove the baffl e 
by fi rst removing the two screws holding the baffl e in place 
(one on each side).  

Lift the baffl e out of the bracket along the back of the fi rebox, 
angle the baffl e slightly and remove it from the fi rebox. 

Figure 8.5

   With the baffl e removed, remove the two screws 

located  in the back of the fi rebox. Reuse the screws to install 
the fl ue restrictor. 

 

Reinstall the baffl e using the two screws 

previously removed.

The  fl ue restrictor should be used in all situations that fall 
within the shaded area on the vent graph.

When your installation falls within a shaded area on the vent 
graph (page 11), a fl ue restrictor must be installed for proper 
operation.

Summary of Contents for TIARA PETITE B TIARAP-BK

Page 1: ...onstruction and safety standard Title 24 CFR Part 3280 or Standard for Installation in Mobile Homes CAN CSA Z240MH This appliance is only for use with the type s of gas indicated on the rating plate I...

Page 2: ...ux tats Unis et au Canada pour les altitudes de 0 4500 0 1370m Pour les altitudes au dessus de 2000 aux tats Unis la configuration du ventilateur son orifice ou les deux peuvent possiblement avoir tre...

Page 3: ...s Pressures 27 C Gas Connection 27 Section 7 Electrical Information A Recommendation for Wire 29 B Connecting to the Appliance 29 C Standing Pilot Ignition System Wiring 29 D Ignition Module Access an...

Page 4: ...o NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control whi...

Page 5: ...vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL...

Page 6: ...ove log set and component pack from firebox Report to your dealer any parts damaged in shipment particularly the condition of the glass Read all of the instructions before starting the instal lation F...

Page 7: ...Provide adequate clearance Around air openings To combustibles For service access Locate appliance away from traffic areas NOTE For actual appliance dimensions refer to Section 12 Fire Risk Locate an...

Page 8: ...Over 16 12 to 18 12 7 0 Over 18 12 to 20 12 7 5 Over 20 12 to 21 12 8 0 3 foot minimum in snow regions Measure vertical clearances from this surface Measure horizontal clearances from this surface See...

Page 9: ...________________________________________________ _ ___________________________________________________________________ _ _ QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet...

Page 10: ...Diagonal runs have both vertical and horizontal vent aspects when calculating the effects Use the rise for the vertical aspect and the run for the horizontal aspect See Figure 5 1 Two 45 elbows may be...

Page 11: ...Example 2 If the vertical dimension from the top of the appliance is 21 ft 6m the horizontal run to the outer wall flange must not exceed 4 ft 3 in 1m 4 Each 90 elbow is equivalent to 3 ft 914mm of ve...

Page 12: ...y Wall thickness may vary Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation needs Note Female ends of direct vent pipe elbows are designed to...

Page 13: ...stucco brick concrete or other types of sidings 2 A termination cap with a built in vinyl siding standoff is highly recommended on a building with vinyl siding The pilot hole will be 2 in 51mm closer...

Page 14: ...e section found on the termination cap WALL THIMBLE COVER WALL THIMBLE Vinyl siding standoff with siding beneath removed SCREWS Bolt horizontal top to vinyl standoff SCREWS Apply sealant to all four s...

Page 15: ...ll Strap Two 45 Elbows Step 2 Set the gas appliance in its desired location Drop a plumb bob down from the ceiling to the position of the appliance flue exit and mark the location where the vent will...

Page 16: ...de requirements as outlined in the current CAN CGA B149 Installation Codes in Canada the National Fuel Gas Code NFPA 54 ANSI Z223 1 in USA or local codes Note that for steep roof pitches the vent heig...

Page 17: ...sheetrocked with standard construction materials however refer to these installation instructions for the minimum allowable clearance between the outside of the vent pipe and the combustible surfaces...

Page 18: ...edges of the support box to make a seal between it and the roof Clean out any combustible material from inside the support box Step 7 Complete the cathedral ceiling installation by following the same...

Page 19: ...6mm Connect the flex pipe to the retro connector and attach with sheet metal screws Step 6 Push the flex pipe back up into the ceiling support box center the retro connector and attach it to the suppo...

Page 20: ...LINEAR CONNECTOR 4 ft 1m OF 3 in 76mm FLEX LINER AIR INTAKE SECTION ALCOVE CLEARANCE TO COMBUSTIBLES MUST BE MAINTAINED CHIMNEY LINER TERMINATION CAP 25 ft 8m OF 3 in 76mm FLEX LINER EXHAUST SECTION T...

Page 21: ...this length extended to its nominal length Be sure to leave 2 3 in 51 76mm of flex above the existing chimney to allow for connection to the termination kit Step 3 Secure the flashing to the top of th...

Page 22: ...Slide wall thimble cover over retro connector and secure with masonry bolts Figure 5 30 If you have a framed wall in front of the masonry use wood screws to mount wall thimble cover to framed wall ove...

Page 23: ...shield and into the brackets on the trim ring Figure 5 34 When installing the trim ring heat shield assem bly make sure the trim ring is centered in the hole and that the shield is above the pipe The...

Page 24: ...ORNER TO COMBUSTILE WALL 2 in 51mm CLEARANCE FROM STOVE CORNER TO COMBUSTIBLE WALL 90 ELBOW HEAT SHIELD OVER PIPE TRIM RING CENTER LINE PIPE LENGTH PIPE LENGTH TERMINATION CAP PLACE MARK WHERE PROTRUD...

Page 25: ...s and logs if installed Remove burner by removing ONLY the two screws indicated DO NOT remove the screws from the burner top Lift the burner up and out of the firebox Figure 6 2 Pull off pilot hood an...

Page 26: ...r remove the three pressure reg ulator mounting screws A pressure regulator tower B and diaphragm C Figure 6 6 Ensure that the rubber gasket D is properly posi tioned and install the new HI LO pressur...

Page 27: ...nected to the 1 2 inch 13mm control valve inlet If substituting for these components please consult local codes for compliance NOTE The gap between the supply piping and gas access hole may be plugged...

Page 28: ...appliance it will take a short time for air to purge from lines When purging is complete the appliance will light and operate normally Air only needs to be purged again if gas valve has been turned to...

Page 29: ...of appliance 4 Use low resistance thermostat wire for wiring from igni tion system to the wall switch and thermostat 5 Use the following chart for wire sizing 6 Keep wire lengths as short as possible...

Page 30: ...the appliance top and place it on a flat surface with the porcelain side up to prevent damage 2 Remove the appliance front by sliding it upwards in the grooves being careful not to chip the porcelain...

Page 31: ...stallation of the flue restrictor requires the removal of the baffle located inside the firebox Remove the baffle by first removing the two screws holding the baffle in place one on each side Lift the...

Page 32: ...shutter Opening the shutter causes flames to become shorter and blue Closing the shutter creates taller orange yellow flames NOTE Do not close so much as to cause a sooty flame Improper adjustment can...

Page 33: ...afety hazard Only Hearth Home Technologies approved accessories may be used safely WARNING Figure 8 10 Place the twig with the center resting on the flat area in the center of the burner and both ends...

Page 34: ...e appliance top and place it on a flat surface with the porcelain side up to prevent damage Remove the back shield by removing the two screws along the top of the shield Place the blower on the floor...

Page 35: ...t using an 11 16 in 17 5 mm wrench Attach the black and white wires routed under the appliance indicated in Figure 8 13 on page 34 to the two speed control wires Push the speed control knob onto the s...

Page 36: ...appliance Pull the top of the glass frame toward you and lift it out of the retainer along the bottom of the firebox Replacement is the reverse of the removal Handle glass assembly with care CAUTION I...

Page 37: ...no gas leaks Ensure that the glass is sealed and in the proper posi tion Ensure that the flow of combustion and ventilation air is not obstructed front grilles and vent caps B Controls FAN SPEED The...

Page 38: ...e power from the appliance 4 Open the door of the appliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five 5 mi...

Page 39: ...ng initial operation Smoke may set off smoke detectors Smoke and odors may be irritating to sensitive individuals CAUTION Prevent accidental appliance operation when not attended Unplug or remove batt...

Page 40: ...thermocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple...

Page 41: ...exhaust gases back into the system Check for proper vent connection at flue collar and all vent joints c Horizontal vent improperly pitched The horizontal vent cap should slope down only enough to pr...

Page 42: ...s door Avoid striking scratching or slamming glass Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Do NOT clean glass when hot Turn off appliance after 3 4 hours of o...

Page 43: ...on Sand and repaint as necessary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burn...

Page 44: ...Dimension Diagram Dimensions are actual appliance dimensions Use for reference only For clearances to combustibles refer to Section 3 Location Inches Millimeters Location Inches Millimeters A 18 1 8 4...

Page 45: ...1 4 in 235mm 6 1 2 in 165mm 6 5 8 in 168mm 17 24 in 432 610mm 11 3 4 in 298mm 5 3 4 in 146mm 6 5 8 in 168mm 6 3 8 in 162mm 6 1 2 in 165mm 9 5 8 in 244mm 6 5 8 in 168mm 6 1 2 in 165mm 6 3 8 in 162mm 9...

Page 46: ...ack SLP36 BK 46 DVA 36B 48 Pipe Length Galvanized SLP48M 46 DVA 48 48 Pipe Length Black SLP48 BK 46 DVA 48B Adjustable Length 3 6 Black SLP6A BK Adjustable Length 3 6 Galvanized SLP6AM Adjustable Leng...

Page 47: ...d a R e v i t a r o c e D Firestop Spacer Ceiling Firestop SLP FSM 46DVA FS Flex Trap Cap with Firestop SLP FLEX TRAP Flex Trap Cap with Firestop and 30 Flex Pipe SLP FLEX TRAP30 Masonry Chimney Conv...

Page 48: ...age Log Set Assembly 1 2 3 Color SKU No Mfg Dates Matte Black TiaraP BK 6 04 Active Brown TiaraP BR 6 04 Active Espresso Tiarap CES 9 07 Active Color SKU No Mfg Dates Almond TiaraP AL 6 04 8 05 Almond...

Page 49: ...6 125 6 Baffle Back 7016 126 7 Side Left or Right TIARAP AL 476 0020PAL TIARAP AL B 476 0020CAL TIARAP BK 476 0020BK TIARAP BR 476 0020PBR TIARAP CES 476 0020CES TIARAP CTO 476 0020CTO TIARAP GR 476 0...

Page 50: ...ITEM DESCRIPTION COMMENTS PART NUMBER 20 1 Blower Shroud Back 7016 132 20 2 Adapter DV 7000 162 Gasket Adapter Elbow 460 0610 20 3 Blower Shroud Top 7016 118 20 4 Latch Draw 229 0640 Y 20 5 Relief Doo...

Page 51: ...touch up paint TIARAP AL B 7026 010 TIARAP BK 7026 003 TIARAP BR 7026 008 TIARAP CES 7026 011 TIARAP CTO 7026 012 TIARAP GR 7026 009 Damper Assembly 7016 006 Flex Line 3 8 Flare X 22L 7000 197 Y Flue...

Page 52: ...purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT deal...

Page 53: ...QRUPDO XVH V D KHDWLQJ DSSOLDQFH VRPH FKDQJHV LQ FRORU RI LQWHULRU DQG H WHULRU VXUIDFH ILQLVKHV PD RFFXU 7KLV LV QRW D IODZ DQG LV QRW FRYHUHG XQGHU ZDUUDQW DPDJH WR SULQWHG SODWHG RU HQDPHOHG VXUID...

Page 54: ...operating and maintenance instructions included Read understand and follow these instruc tions for safe installation and operation Leave this manual with party responsible for use and operation Heat G...