background image

Heat & Glo  •  ST-36TVB-IPI  •  2134-900 Rev. i  •  3/13

2

Listing Label Information/Location

Model Name: ___________________________________________ Date purchased/installed: __________________

Serial Number: __________________________________________ Location on fi replace: _____________________

Dealership purchased from:  _______________________________ Dealer Phone:  __________________________

Notes: _______________________________________________________________________________________

_____________________________________________________________________________________________

A. Congratulations

Congratulations on selecting a Heat & Glo gas fi replace, an 
elegant and clean alternative to wood burning fi replaces. 
The Heat & Glo gas fi replace you have selected is designed 
to provide the utmost in safety, reliability, and effi ciency.

As the owner of a new fi replace, you’ll want to read and 
carefully follow all of the instructions contained in this 
owner’s manual. Pay special attention to all cautions and 
warnings.

This owner’s manual should be retained for future 
reference. We suggest that you keep it with your other 
important documents and product manuals.

The information contained in this owner’s manual, unless 
noted otherwise, applies to all models and gas control 
systems.

Your new Heat & Glo gas fi replace will give you years of 
durable use and trouble-free enjoyment. Welcome to the 
Heat & Glo family of fi replace products!

We recommend that you record the following pertinent 
information about your fi replace.

Gas and Electric 
Information

Serial Number

Type of Gas

The model information regarding your specifi c fi replace can be found on 
the rating plate usually located in the control area of the fi replace.

Homeowner Reference Information

Model Number

Not

Not for 

for use 

use with 

with solid 

solid fuel.

fuel.

((

Ne 

Ne doit 

doit pas 

pas entre 

entre utilise 

utilise avec 

avec un 

un combustible 

combustible solide).

solide).

This

This appliance 

appliance must 

must be 

be installed 

installed in 

in accordance 

accordance with 

with local 

local codes, 

codes, if 

if any; 

any; if 

if not, 

not, follow 

follow ANSI 

ANSI Z223.1

Z223.1

in

in the 

the USA 

USA or 

or CAN/CGA 

CAN/CGA B149 

B149 installation 

installation codes. 

codes.

(Installer

(Installer l’appareil 

l’appareil selon 

selon les 

les codes 

codes ou 

ou reglements

reglements

locaux 

locaux ou, 

ou, en 

en l’absence 

l’absence de 

de tels 

tels reglements, 

reglements, selon 

selon les 

les codes 

codes d’installation 

d’installation CAN/CGA-B149.)

CAN/CGA-B149.)

Type 

Type of 

of Gas 

Gas

(Sorte 

(Sorte De 

De Gaz)

Gaz)

::

N

NA

ATURAL

TURAL  GAS

GAS

MADE

MADE   IN 

IN   USA

USA

Minimum

Minimum Permissible 

Permissible Gas 

Gas Supply 

Supply for 

for Purposes 

Purposes of 

of Input 

Input Adjustment.

Adjustment.

Approved 

Approved Minimum 

Minimum

(De

(De Gaz) 

Gaz) 

Acceptable

Acceptable

0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Maximum

Maximum Pressure 

Pressure 

(Pression)

(Pression)

 0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Maximum

Maximum Manifold 

Manifold Pressure 

Pressure 

(Pression)

(Pression)

   

   0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Minimum

Minimum Manifold 

Manifold Pressure 

Pressure 

(Pression)

(Pression)

   

   0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Model:

Model:
(Modele):

(Modele):

Serial

Serial
(Serie):

(Serie):

ANSI

ANSI Z21XX-XXXX 

Z21XX-XXXX · 

· CSA 

CSA 2.XX-MXX 

2.XX-MXX  

XXXXXXXX

XXXXXXXX

IN

IN CANADA

CANADA

ALTITUDE:

ALTITUDE:

0-0000 

0-0000 FT.

FT.

0000-0000FT.

0000-0000FT.

MAX. 

MAX. INPUT 

INPUT BTUH:

BTUH:

00,000

00,000

00,000

00,000

MIN.

MIN. INPUT 

INPUT BTUH:

BTUH:

00,000

00,000

00,000

00,000

ORIFICE

ORIFICE SIZE:

SIZE:

#XXXXX

#XXXXX

#XXXXX

#XXXXX

XXXXXXXX

XXXXXXXX

Total 

Total Electrical 

Electrical Requirements: 

Requirements: 000Vac, 

000Vac, 00Hz., 

00Hz., less 

less than 

than 00 

00 Amperes

Amperes

Heat & Glo, a brand of Hearth & Home Technologies
7571 215th Street West, Lakeville, MN   55044

Read this manual before installing or operating this appliance. 

Please retain this owner’s manual for future reference.

Summary of Contents for ST-36TVB-IPI

Page 1: ...use and operation DO NOT DISCARD WARNING Important operating and maintenance instructions included Read understand and follow these instructions for safe installation and operation In the Commonwealth...

Page 2: ...e utilise avec avec un un combustible combustible solide solide This This appliance appliance must must be be installed installed in in accordance accordance with with local local codes codes if if an...

Page 3: ...pplies Needed 15 D Inspect Appliance and Components 15 E Negative Pressure 16 5 Framing and Clearances A Selecting Appliance Location 17 B Constructing the Appliance Chase 18 C Clearances 18 D Mantel...

Page 4: ...VB IPI 2134 900 Rev i 3 13 4 Contains updated information 15 Troubleshooting A Intellifire Ignition System 40 16 Reference Materials A Appliance Dimension Diagram 42 B Service Parts List 45 C Contact...

Page 5: ...ase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer dis...

Page 6: ...ED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surf...

Page 7: ...n Materials made of or surfaced with wood compressed pa per plant fibers plastics or other material that can ignite and burn whether flame proofed or not or plastered or unplastered shall be considere...

Page 8: ...help is needed to properly install one HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow childre...

Page 9: ...event direct contact with the fixed glass panel DO NOT operate the fireplace with the barrier removed Contact your dealer or Hearth Home Technologies if the barrier is not present or help is needed to...

Page 10: ...r because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building...

Page 11: ...utes Odor from fireplace When first operated this fireplace may release an odor for the first several hours This is caused by the curing of materials from manufacturing Odor may also be released from...

Page 12: ...servicing When properly maintained your fireplace will give you many years of trouble free service We recommend an nual service by a qualified service technician Doors Surrounds Fronts Frequency Annua...

Page 13: ...ese areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annuall...

Page 14: ...S ROOF PREFERABLY WITHOUT AFFECTING ROOF RAFTERS SECTION 8B FRAMING HEADED OFF IN CEILING JOISTS SECTION 8B GAS LINE SECTION 11 MANTEL AND MANTEL LEG SECTION 5 D SURROUND HEARTH EXTENSION VENT PIPE SE...

Page 15: ...ce any part of the control system and or gas control which has been under water Improper installation adjustment alteration service or maintenance can cause injury or property damage For as sistance o...

Page 16: ...appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fireplace Avoid installing the fireplace near doors walkways or smal...

Page 17: ...Burns Provide adequate clearance around air openings and for service access Due to high temperatures the appliance should be locat ed out of traffic and away from furniture and draperies NOTICE Illust...

Page 18: ...aces extending full width and depth DO NOT install directly on carpeting vinyl tile or any combustible material other than wood WARNING Risk of Fire Maintain specified air space clearances to applianc...

Page 19: ...ll Combustible Mantel Legs or Wall Projections Figure 5 6 Non Combustible Zone SHEETROCK AIR SPACE REQUIRED 3 1 4 in D Mantel and Wall Projections WARNING Risk of Fire Comply with all minimum clear an...

Page 20: ...insulation or other materials Failure to keep insulation or other materials away from vent pipe may cause overheating and fire WARNING VERTICAL WALL LISTED B VENT TERMINATION CAP 12 X ROOF PITCH IS X...

Page 21: ...UPPORTS ARE PER VENT MANUFACTURER S SPECIFICATIONS METAL PLUMBER S STRAP 12 FEET MINIMUM 50 FEET MAXIMUM VENT SUPPORTS ARE PER VENT MANUFACTURER S SPECIFICATIONS MINIMUM CLEARANCES ARE PER VENT MANUFA...

Page 22: ...instructions to provide adequate clear ances Use same size framing materials as those used in the wall or ceiling construction Firestop spacers must be used in wall and ceiling penetrations per the B...

Page 23: ...may result Remove and discard cover plate or knockout from side of appliance Open air kit damper slightly Locate door hinge toward back of appliance see Figure 9 1 9 9 Appliance Preparation Figure 9...

Page 24: ...ppliance into position making sure to maintain proper clearance to combustibles 2 Level the appliance from side to side and front to back It is acceptable to use wood shims under the appliance 3 Faste...

Page 25: ...Shield WARNING Fire Risk DO NOT allow loose materials or insulation to touch vent Hearth Home Technologies Inc requires the use of an attic shield The National Fuel Gas Code ANSI Z223 1 and NFPA 54 re...

Page 26: ...flame Fittings and connections could have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the factory WARNING Risk of Fire or Exp...

Page 27: ...verride IPI safety lockout Refer to Figures 12 1 and 12 2 Intellifire Pilot Ignition IPI Wiring Diagram This appliance is equipped with an Intellifire control valve which operates on a 3 volt system P...

Page 28: ...lifire Ignition Wiring Diagram with Wall Switch RED VALVE TRANSFORMER 3V BLACK B R O W N WIRE ASSEMBLY GROUND TO FIREPLACE CHASSIS TEMP SENSOR BATTERY PACK ORG GREEN B R O W N PLUG IN BLACK BLACK WHIT...

Page 29: ...Ignition Wiring Diagram with Remote Receiver RED VALVE TRANSFORMER 3V BLACK B R O W N GROUND TO FIREPLACE CHASSIS TEMP SENSOR BATTERY PACK ORG GREEN B R O W N PLUG IN BLACK BLACK REMOTE RECEIVER PLUG...

Page 30: ...rough the knockout making sure to use a Romex connector to fasten the electrical wires to the unit Pull enough wire into the valve compartment to easily reach the junction box location Remove the scre...

Page 31: ...the appliance during the installation process before finishing work on the whole hearth is complete Splatter guards may be factory installed or accompany the door of the unit depending on the fire pla...

Page 32: ...and fold up the panel as shown in Figure 13 8 Disengage the tabs on left and right bottom of splatter guard and fit them into the square holes The tabs are now inside the front of the splatter guard c...

Page 33: ...8 7 6 1 2 3 4 5 6 12 32 MAX MIN TO CEILING Figure 13 13 Minimum Vertical and Maximum Horizontal Dimensions of Non Combustibles C Facing Material Metal front faces may be covered with non combustible m...

Page 34: ...7 Inside Any 13 18 Halston Overlap 1 inch 13 17 Inside 1 inch 2 inch 13 19 Chateau Overlap 1 inch 13 17 Inside Any 13 18 Valencia Overlap 1 inch 13 17 Inside Any 13 18 Galleria Overlap 1 inch 13 17 In...

Page 35: ...See Note 2 KENWOOD MANTEL AFKDMPB 0 See Note 3 0 27 3 8 in KENWOOD MANTEL W BASE AFKDMPB W HTKDMPB 9 1 4 in 235 mm 29 3 8 in LAURENT SURROUND LAURENT 36 1 1 2 in 38 mm N A CAMDEN SURROUND CAM36PG 0 N...

Page 36: ...r material annually Improperly placed embers interfere with proper burner operation Ember material is shipped with this gas appliance To place the ember material Embers CANNOT be placed directly over...

Page 37: ...nside of the fireplace See Figure 1 Remove the microfoam and inspect the logs for damage Inspect the four factory installed logs for damage Locate the pilot in order to verify your position in relatio...

Page 38: ...top of the end of log C STEP 4 Log 3 SRV2128 707 The bottom end of log 3 should come in contact with the far left grate tine Mate the bottom of log 3 with the indentations on Log D and the top of Log...

Page 39: ...er Figure 14 2 Fixed Glass Assembly G Fixed Glass Assembly WARNING Risk of Asphyxiation Handle fixed glass assembly with care Inspect the gasket to ensure it is undamaged and inspect the glass for cra...

Page 40: ...parker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark a No power or transformer installed incorrectly Verify that transformer is i...

Page 41: ...hould glow shortly after ignition Verify cor rect pilot orifice is installed and gas inlet is set to pressure specifications c Module is not grounded Verify module is securely grounded to metal chassi...

Page 42: ...g dimensions and clearances refer to Section 5 Figure 16 1 Appliance Dimensions Location Inches Millimeters I 4 1 4 108 J 24 610 K 12 305 L 21 5 16 541 M 5 127 N 38 965 O 1 25 Location Inches Millimet...

Page 43: ...________________________ ________________________________________________________________________________ ________________________________________________________________________________ _____________...

Reviews: