E. Junction Box Installation
If the box is being wired from the
OUTSIDE
of the
appliance:
• Remove the cover plate located on the outer shell
- right side (see Figure 10.3).
• Install the supplied Romex
™
connector in the cover
plate.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections and reattach
the cover plate to the outer shell.
If the box is being wired from the
INSIDE
of the
appliance:
• Remove the screw attaching the junction box/
receptacle to the outer shell, rotate the junction
box inward to disengage it from the outer shell (see
Figure 10.3).
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
• Feed the necessary length of wire through the connector.
• Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle to the
outer shell.
Figure 10.4
1
. Remove the screw and knob from the variable regulator
and discard.
2. Unscrew the nut from the regulator and discard.
3. Remove the bag containing a washer and blue and red
plungers from the side of the
fl
ame control solenoid.
4. Place washer on
fl
ame control solenoid (see Figure
10.4).
5. Insert the blue plunger into the
fl
ame control solenoid
(see Figure 10.4).
6. Thread the
fl
ame control solenoid with correct plunger
into the thread hole in the variable regulator. Turn one to
two turns only. Do not tighten or damage may occur.
7. Connect orange wires from control box to the
fl
ame
control solenoid.
VARIABLE
REGULATOR
GAS CONTROL
VALVE
FLAME CONTROL
SOLENOID
KNOB
SCREW
NUT
VARIABLE REGULATOR
JAM NUT
VARIABLE
REGULATOR
SOLENOID
WASHER
WASHER
PLUNGER
F. Installing Flame Control Solenoid (Natural Gas Only)
WHT
WHT
BLK
BLK
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebox
Romex
Connector
Figure 10.3 Junction Box Detail
NOTE:
Do NOT wire
110VAC to wall switch.