37
Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. J • 3/13
Rear Vent - Vertical Termination - (continued)
Three Elbows
Figure 7.17
Three Elbows
Figure 7.18
INSTALLED
HORIZONTALLY
H
3
H
1
H
2
V
1
V
2
V
1
H
2
H
1
USE DVP SERIES COMPONENTS ONLY
USE DVP SERIES COMPONENTS ONLY
H
1
H
2
H
3
V
1
Minimum
H
1
+ H
2
+ H
3
Maximum
*
*
*
8 ft.
2,44 m
6 ft.
1,83 m
*
*
*
9 ft.
2,74 m
7 ft.
2,13 m
*
*
*
10 ft.
3,05 m
8 ft.
2,44 m
*
*
*
10 ft.
3,05 m
8 ft.
2,44 m
V
1
+ H
1
+ H
2
+ H
3
= 32 ft. (9,75 m) Maximum
*No specific restrictions on this value EXCEPT
V
1
+ H
1
+ H
2
+ H
3
cannot exceed 32 ft. (9,75 m) Maximum
H
1
+ H
2
+ H
3
= 8 ft. (2,44 m) Maximum
H
1
Maximum
V
1
Minimum
H
2
H
1
+ H
2
Maximum
6 in.
15,2 cm
6 in.
15,2 cm
6 in.
15,2 cm
1 ft.
30,5 cm
1 ft.
30,5 cm
1 ft.
30,5 cm
1 ft.
30,5 cm
2 ft.
61,0 cm
2 ft.
61,0 cm
2 ft.
61,0 cm
3 ft.
91,4 cm
4 ft.
1,22 m
3 ft.
91,4 cm
3 ft.
91,4 cm
6 ft.
1,83 m
7 ft.
2,13 m
4 ft.
1,22 m
4 ft.
1,22 m
8 ft.
2,44 m
9 ft.
2,74 m
5 ft.
1,52 m
5 ft.
1,52 m
8 ft.
2,44 m
12 ft.
3,66 m
H
1
= 5 ft. (1,52 m) Max. V
1
+ V
2
+ H
1
+ H
2
= 36 ft. (10,97 m) Max.
H
1
+ H
2
= 12 ft. (3,66 m) Max.