Heat & Glo • SL-550METRO, SL-550METRO-LP • 2185-900 Rev. D • 8/09
54
WHT
WHT
BLK
BLK
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebox
Romex
Connector
Figure 12.4 Junction Box Detail
NOTICE: DO NOT wire
110 VAC to wall switch.
E. Junction Box Installation
If the box is being wired from the
INSIDE
of the appli-
ance:
• Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to dis-
engage it from the outer shell (see Figure 12.4).
• Pull the electrical wires from outside the appliance through
the opening into the valve compartment and secure wires
with a Romex connector. See Figure 12.4.
• Make all necessary wire connections to the junction
box/receptacle and reattach the junction box/receptacle
to the outer shell.