background image

4

Heat & Glo  • Primo Clean Face Finish Instructions  •  2310-925 Rev. D  •  8/15

Figure 3.

1/2 INCH SHEETROCK WALL

The PRIMO appliance can be 

fi

 nished with 1/2 inch 

sheetrock.  Non-combustible 

fi

 nishing is not required.  

8 INCHES ALL SIDES

Figure 5. Feather Mud Evenly

Preparation

1.  Install 1/2 inch sheetrock on wall. Figure 3 shows 

the PRIMO installed.  Sheetrock (1/2 inch) has been 
installed up to the top, bottom and sides of appliance 
opening as shown in Figure 2 and 3. See the appliance 
installation manual for more details regarding facing 
material.

KIT COMPONENTS 

(1)  Left Glass Panel
(1)  Right Glass Panel
(1)  Back Glass Panel (Single-sided models only)
(3)  Glass Retaining Brackets
(2)  Glass Clips
(1)  Barrier Glass* (Qty 2 on See-Through models)
*See appliance installation manual for barrier glass instal-
lation instructions.

4.  Glass Panel Instructions

Single-Sided Models: 

Set back glass panel, in location A in Figure 6 into 

fi

 rebox.  

Back panel will sit on the heads of the screws holding 
the media tray in place.  Set back glass panel against 
the back wall of the 

fi

 rebox with the smooth side of the 

glass facing outward. Place retaining bracket over panel 
so holes in the bracket are against the 

fi

 rebox back.  Use 

two self-drilling screws to secure to the 

fi

 rebox back.   En-

sure glass panel is stationary.  See Figure 7.  

Position the glass clip as shown in Figure 8. 

NOTICE: 

Fasteners are not used with glass clip.

Set left side glass panel, in location B in Figure 6, into 

fi

 re-

box with the smooth side facing outward.   Place retaining 
bracket over panel so holes in the bracket are against 
the 

fi

 rebox side.  Use two self-drilling screws to secure 

to the 

fi

 rebox side. See Figure 7.  Ensure glass panel is 

stationary.   

Repeat for right side panel.

See-Through Models: 

Position the glass clip as shown in Figure 8. 

NOTICE: 

Fasteners are not used with glass clip.

Set left side glass panel, labeled B in Figure 6, into 

fi

 re-

box with the smooth side facing outward.  Place retain-
ing bracket over glass panel so holes in the bracket are 
against the 

fi

 rebox side.  Use two self-drilling screws to 

secure the bracket to the 

fi

 rebox side.  See Figure 7. Re-

peat for right side panel.  

2.  Install sheetrock trim strips as shown in Figure 4 on all 

sides of appliance.  Sheetrock trim strips are included 
with the appliance. Cut the strips to the required 
length and install them using staples. See Figure 4 for 
placement of trim strips.

Figure 4.  Install Sheetrock Trim Strips

SHEETROCK TRIM STRIPS

SHEETROCK TRIM STRIPS
(INSTALLED ON ALL 4 SIDES)

(INSTALLED ON ALL 4 SIDES)

SHEETROCK 

SHEETROCK 
TRIM STRIPS 

TRIM STRIPS 

(INSTALLED 

(INSTALLED 

ON ALL 4 

ON ALL 4 

SIDES)

SIDES)

CORRECT

Installed OVER painted stop

INCORRECT

Installed UNDER painted stop

Summary of Contents for PRIMO48-CF

Page 1: ...acing and Finishing General Information WARNING Risk of Fire Comply with all minimum clear ances to combustibles as specified Framing closer than the minimums listed must be constructed entirely of noncom bustible materials i e steel studs concrete board etc Splatter Guard The splatter guard is a piece of corrugated material used to protect the appliance during the installation process before fini...

Page 2: ...r overhang into the glass opening See Figure 2 Facing materials may be combustible or non combustible The appliance is designed to be used with 1 2 in wall sheathing materials such as drywall plywood wood composites or non combustible materials WARNING Risk of Fire DO NOT apply combustible materials beyond the minimum clearances Comply with all minimum clearances to combustibles as specified in th...

Page 3: ...3 Heat Glo Primo Clean Face Finish Instructions 2310 925 Rev D 8 15 SHEET ROCK WALL 1 2 IN SHEETROCK SHEETROCK STOPS AT RETURN BEND APPLIANCE OPENING Figure 2 Sheetrock Detail for Both Finishing Methods ...

Page 4: ...x back En sure glass panel is stationary See Figure 7 Position the glass clip as shown in Figure 8 NOTICE Fasteners are not used with glass clip Set left side glass panel in location B in Figure 6 into fire box with the smooth side facing outward Place retaining bracket over panel so holes in the bracket are against the firebox side Use two self drilling screws to secure to the firebox side See Fi...

Page 5: ...re 8 Position Glass Clip and Install Glass Panel NOTICE Fasteners are not used with glass clip Figure 9 Barrier Glass Support Figure 10 Break Barrier Glass Support Figure 11 Form Barrier Glass Support BREAK LINE BREAK LINE HAND BEND AT 90 DEGREES HAND BEND AT 90 DEGREES 5 Break the barrier glass support into two pieces as shown in Figures 9 and 10 Make the hand bends as shown in Figure 11 to form ...

Page 6: ...G SCREW LOCATION SELF TAPPING SCREW LOCATION ATTACH RUBBER BUMPERS ATTACH RUBBER BUMPERS BARRIER GLASS SUPPORT BARRIER GLASS SUPPORT EXISTING SCREW LOCATION EXISTING SCREW LOCATION LOWER ACCESS COVER PANEL APPLIANCE OUTER WRAP A REMOVE EXISTING SCREW D DRIVE SELF TAPPING SCREW C REINSTALL EXISTING SCREW B POSITION BARRIER GLASS SUPPORT INSTALLED SHOULDER BOLT Figure 13 Install Barrier Glass Suppor...

Page 7: ...ransition Glass Panel Bracket EXISTING HOLES EXISTING HOLES 8 Install glass transition panel bracket on left and right sides of appliance opening using two self tapping screws See Figures 14 15 and 16 for details 9 Install transition glass panels by securing with tabs on left and right sides of appliance See Figures 16 and 17 Figure 14 Form Transition Glass Panel Bracket SELF TAPPING SCREWS GO SEL...

Page 8: ...ION GLASS TRANSITION GLASS PANEL BRACKET PANEL BRACKET TRANSITION GLASS TRANSITION GLASS TAB TAB TRANSITION TRANSITION GLASS PANEL GLASS PANEL TRANSITION GLASS TAB TRANSITION GLASS TAB ATTACHMENT HOLES SELF TAPPING SCREWS TRANSITION MEDIA TRAY TRANSITION GLASS PANEL BRACKET INSTALLED TRANSITION GLASS PANEL INSTALLED ...

Page 9: ... or Non Combustible NOTICE Dimensions must be same as dimensions in Figure 3 3 If dimensions vary barrier glass can not be removed MODEL X Min Y Min PRIMO48 48ST 51 13 3 8 PRIMO60 60ST 63 13 3 8 PRIMO72 72ST 75 13 3 8 NOTICE Dimensions must be same as dimensions in Clean Face Finish Dimensions diagram Section 3 of appliance Installation Manual for Clean Face Finish If dimensions vary barrier glass...

Page 10: ...06 GLA2310 106 Transition Glass Panel Bracket 2310 120 2310 120 DESCRIPTION PRIMO60 PRIMO60ST KIT PRIMO60 CF PRIMO60ST CF Firebox Panel Glass Assembly 2321 060 2301 060 Transition Panel Glass Assembly 2310 032 2310 032 Glass Retaining Bracket 2300 133 2300 133 Barrier Glass Support 2310 134 2310 134 Rubber Bumper 2310 140 2310 140 Transition Glass Tab 2310 145 2310 145 Clean Face Barrier Glass GLA...

Reviews: