Heat & Glo • EM-42 • 28324 Rev U • 02/07
25
Asphyxiation Risk
•
Damper must be locked open when gas logs
installed.
Gas
¿
re generates fumes.
WARNING
Fire Risk
• For use with solid wood fuel or decorative
gas appliance only.
• DO NOT install unvented gas logs.
WARNING
Fire Risk
Explosion Risk
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components
Report damaged parts to dealer.
WARNING
WHT
(Silver Screw)
Ground
Blower
Receptacle
110V Supply
1. Fan
BLK
WHT
Ground
Wall
Junction
Box
Ground
Screw
BLK
(Brass Screw)
WHT
Ground
BLK
Wall
Switch
to 110V house
wiring
Figure 7.5
Wiring for Fan Kit
Shock Risk
Circulating Fireplace Only
• Do NOT remove grounding prong from
plug.
• Plug directly into properly grounded three-
prong receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of
appliance.
CAUTION
Note:
If a speed control option is desired, it is recommended
that you use the BC10 Motor Speed Control Kit supplied
with the
¿
replace to ensure proper functioning. Refer to the
instructions packed with it for proper installation.
C. Installation of Fan
The EM-42 is a heat circulating
¿
replace that comes equipped
with a fan kit, junction box, and an ON/OFF variable speed
control (wall mount type).
110 VAC service must be connected to the fan kit by a li-
censed electrician. See Figure 7.5 for the typical fan kit wir-
ing diagram and the typical access to the junction box.
To service or replace the fan kit:
• Remove the lower
¿
replace grille.
• Unplug the blower from the junction box on the
¿
replace.
•
Remove the screws for the blower mounting brackets and
carefully slide blower out of the
¿
replace.
• To reinstall the fan kit, reverse these steps.
We recommend the fan kit be installed at the time of initial
installation of the
¿
replace to avoid considerable reconstruc-
tion.