Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08
36
Figure 14.3
Remove the tube burner. It is held in place with
one screw. Pull the burner tube away from orifi ce holder,
rotating burner tube slightly, and remove it from the orifi ce.
Figure 14.4
The fan plate can now be accessed. Remove
the four screws. Lift the fan plate, being careful to not cut or
scar wiring while disconnecting them from the fan motor.
Figure 14.2
The glass platform plate can now be removed
by removing the 13 screws on the outer edge of this plat-
form. Lift the platform. The HSI (Hot Surface Ignitor) and
the sensor wire can be unplugged. Set platform aside.