background image

Heat & Glo  •  Soho-CE  •  2111-900 Rev. D  •  6/07

1

Model:
Soho-CE

•  Do not store or use gasoline or other fl am-

mable vapors and liquids in the vicinity of 
this or any other appliance.

•  What to do if you smell gas   

-  Do  not  try  to  light  any  appliance                                                                       
-  Do not touch any electrical switch.
  Do not use any phone in your building.
-  Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 
supplier’s instructions.

-  If you cannot reach your gas supplier, 

call the fi re department.

•  Installation and service must be performed 

by a qualifi ed installer, service agency, or 
the gas supplier.

WARNING: If the information in 

these instructions is not followed 
exactly, a fi re or explosion may result 
causing property damage, personal 
injury, or death.

HOT! DO NOT TOUCH

SEVERE BURNS MAY RESULT.

CLOTHING IGNITION MAY RESULT.

•  CAREFULLY SUPERVISE children in same room as 

appliance.

•  Alert children and adults to hazards of high temperatures.

•  Do NOT operate with protective barriers open or 

removed.

•  Keep clothing, furniture, draperies and other 

combustibles away.

Glass and other surfaces are hot during 
operation and cool down.

• Keep 

children 

away.   

 

 

Installer’s Guide

Installation and Operation

WARNING

0063-06

This is a room sealed appliance and no other ventilation is 
required than what is provided.

These instructions are only valid if the following country 
symbol is on the appliance.  If this symbol is not present 
on the appliance, it is necessary to refer to the technical 
instructions which will provide the necessary information 
concerning the modifi cation of the appliance to the conditions 
of use for the country.

These instructions are valid for the following countries: GB, IE

This appliance is not supplied with an integral barrier to 
prevent direct contact with the fi xed glass panel. Do NOT 
operate the appliance without a protective barrier installed.

Contact your dealer or Hearth & Home Technologies if help is 
needed to properly install one.

Summary of Contents for Balanced Flue Gas Fireplace SOHO-CE

Page 1: ...hildren and adults to hazards of high temperatures Do NOT operate with protective barriers open or removed Keep clothing furniture draperies and other combustibles away Glass and other surfaces are ho...

Page 2: ...in safety reliability and efficiency As the owner of a new appliance you ll want to read and carefully follow all of the instructions contained in this Installer s Guide Pay special attention to all...

Page 3: ...Appliance Preparation A Securing and Leveling the Appliance 17 8 Installing Flue Pipe A Assembly of Flue Sections 18 B Installing Firestops and Horizontal Termination Cap 19 C Install Roof Flashing a...

Page 4: ...E 136 Stan dard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C shall be considered non com bustible materials C Combustible Materials Specification Materials made of or surf...

Page 5: ...components and trim doors are shipped in separate packages The logs are packaged separately inside the fireplace and must be field installed Report to your dealer any parts damaged in shipment particu...

Page 6: ...ng and Clearances Note Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design...

Page 7: ...ding codes MUST be checked Chases should be constructed in the manner of all out side walls of the home to prevent cold air drafting prob lems The chase should not break the outside building envelope...

Page 8: ...12 to 20 12 2 29 Over 20 12 to 21 12 2 44 Figure 4 1 Figure 4 2 Minimum height from roof to lowest discharge opening 4 4 Termination Locations Measure horizontal clearances from this surface Measure...

Page 9: ...en on a minimum of 2 sides beneath the floor or meets Note 2 NOTE 1 On private property where termination is less than 7 feet above a sidewalk driveway deck porch veranda or balcony use of a listed ca...

Page 10: ...90 elbow On 45 runs 30 5 cm of diagonal is equal to 21 6 centimeters horizontal run and 21 6 centimeters vertical run A length of straight pipe is allowed between two 45 elbows see Flue diagrams Figu...

Page 11: ...Elbows V1 H1 Two Elbows V Minimum H1 H2 Maximum Elbow only Not Allowed 30 cm 91 cm 61 cm 1 8 m 91 cm 2 7 m 1 2 m 3 7 m 1 5 m 4 6 m V H1 H2 Maximum 11 9 m H1 H2 Maximum 4 6 m D Flue Diagrams One Elbow...

Page 12: ...rizontal Termination continued Three Elbows Three Elbows V1 Minimum H1 Maximum V2 Minimum H2 Maximum 30 cm 61 cm 30 cm 61 cm 61 cm 1 2 m 61 cm 1 2 m 91 cm 1 8 m 91 cm 1 8 m 1 2 m 2 4 m 1 2 m 2 2 m V1...

Page 13: ...ertical Termination No Elbow Figure 5 6 Figure 5 7 Two Elbows V1 11 8 m Maximum V1 V1 V2 H1 Two Elbows V1 Minimum H Maximum Elbow only 46 cm 30 cm 91 cm 61 cm 1 2 m 91 cm 1 8 m 1 2 m 2 4 m 1 8 m 4 6 m...

Page 14: ...4 Figure 5 8 2 Vertical Termination continued Three Elbows V2 H2 V1 INSTALLED HORIZONTALLY H1 Three Elbows V1 Minimum H1 H2 Maximum 30 cm 61 cm 61 cm 91 cm 91 cm 1 5 m 1 2 m 2 1 m 1 5 m 4 3 m V1 V2 H1...

Page 15: ...eter 2 54 cm greater than the pipe is acceptable B Wall Penetration Framing Figure 6 2 Exterior Wall Hole A B 25 4 cm Shows center of flue framing hole The center of the hole is one 2 54 cm above the...

Page 16: ...dditional ceiling firestop is not required if attic shield is used Frame opening for attic shield Attic shield may be installed above or below ceiling see Figure 6 4 Secure with three fasteners on eac...

Page 17: ...de to side and front to back Shim the appliance as necessary It is acceptable to use wood shims Bend out nailing tabs on each side Keep nailing tabs flush with the framing Secure the appliance to the...

Page 18: ...e the pipe section clockwise about one quarter 1 4 turn see Figure 8 1 The flue pipe is now locked together Slide the ceramic rope ring over the first flue section and place it flush to the appliance...

Page 19: ...ut a 25 4 cm x 25 4 cm hole for SL D series pipe The center of the framing hole is 2 54 cm above the center of the horizontal flue pipe Position the wall shield firestops on both sides of the hole pre...

Page 20: ...sk Explosion Risk Inspect external flue cap regularly Ensure no debris blocks cap Combustible materials blocking cap may ignite Restricted air flow affects burner operation WARNING Roof Pitch H Min Me...

Page 21: ...around the exposed pipe section and align brackets Insert a bolt provided through the brackets and tighten nut to complete storm collar assembly see Figure 8 7 Slide the assembled storm collar down th...

Page 22: ...est all gas line points and the gas control valve prior to and after starting the gas appliance Table 1 9 9 Gas Information Natural Gas G20 Propane G31 Butane G30 Natural Gas G25 Inlet Pressure 20mbar...

Page 23: ...system The batteries are located within the ignition module which is located under the unit A wiring diagram is shown in Figure 7 1 The battery pack requires four AA batteries not included Figure 10...

Page 24: ...ZONE FINISH WALL MATERIAL MAY BE COMBUSTIBLE TOP AND SIDES 20 3 cm 74 cm 0 cm 0 cm 0 cm B Mantel Projections No mantels are allowed when using Studio CE fronts Risk of Fire Non combustible clearances...

Page 25: ...l Ember material is shipped with this gas appliance To place the ember material Place small pieces of ember material on burner top around burner ports Do NOT press embers into burner ports Do NOT plac...

Page 26: ...cating tab Step 2 Place Log 2 SRV2111 701 onto base pan such that Log 2 fits in groove of Log 1 Push it back against the left hand side locating tab Ensure burner ports are not covered by logs Step 3...

Page 27: ...ly Replace the glass door on the appliance Pull out and latch the two glass assembly latches into the groove on the glass frame on the bottom and top edges BOTTOM LATCH GLASS ASSEMBLY Handle glass doo...

Page 28: ...nance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or...

Page 29: ...settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance DO NOT CONNECT 240 VAC TO THE CONTROL VALVE Improper installation adjustment alteration service or maintenance can cau...

Page 30: ...off smoke detectors Smoke and odors may be irritating to sensitive individuals CAUTION Fire Hazard Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance Do NOT...

Page 31: ...along cable D Valve Replace valve Do not over tighten E Over tightened thermocouple interrupter Replace valve and thermocouple interrupter F Receiver Replace receiver and reprogram code 5 Pilot is lit...

Page 32: ...lass after initial 3 4 hours operation Longer operation without cleaning glass may cause a permanent white film on glass CAUTION When cleaning glass door Avoid striking scratching or slamming glass Do...

Page 33: ...rrect as necessary Firebox 1 Inspect for paint condition warpage corrosion or perforation Sand and repaint as necessary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation...

Page 34: ...5 6 O 94 0 G 11 5 P 9 6 H 83 2 Q 5 7 I 58 6 Appliance Dimensions Table Figure 16 1 Appliance Dimensions A B C D E F G H I J K L M N O P Q GAS LINE ACCESS ELECTRICAL ACCESS 16 16 Reference Materials A...

Page 35: ...2111 900 Rev D 6 07 35 4 5 6 7 8 9 10 11 12 1 2 3 Service Parts List Part number list on following page Log Set Assembly Service Parts Diagram SOHO CE Beginning Manufacturing Date 1 07 Ending Manufact...

Page 36: ...Base Pan 2111 101 8 Burner Assembly N 2111 020 Burner Assembly P 2111 022 Burner Assembly B 2111 024 9 Glass Assembly GLA SOHOCE 10 Mesh Assembly 2077 011 11 Decorative Front DF SOHOCE BK 12 Module H...

Page 37: ...024 3 Pilot Bracket 2111 123 4 Flex Tube Assembly 530 302A 5 Burner Neck Gasket 438 407 6 Valve Plate Gasket 2077 138 7 Valve Bracket 2111 186 8 Thermocouple block 2098 146 9 Valve N 2098 138 Valve B...

Page 38: ...roduct or added thereafter are NOT covered by this war ranty unless expressly authorized and approved by HEAT GLO in writing 6 Any damages caused by environmental conditions inadequate ventilation or...

Page 39: ...__ D Contact Information Please contact your Heat Glo dealer with any questions or concerns For the location of your nearest Heat Glo dealer please visit www heatnglo com Printed in U S A Copyright 20...

Reviews: