13
Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08
METAL
PLUMBER’S
STRAP
9 FEET
MINIMUM
VENT SUPPORTS ARE PER
VENT MANUFACTURER’S
SPECIFICATIONS
MINIMUM CLEARANCES
ARE PER VENT
MANUFACTURER’S
SPECIFICATIONS
METAL
PLUMBERS' STRAP
MAXIMUM HORIZONTAL RUN IS 50%
OF VERTICAL. HORIZONTAL RUN
CANNOT BE MORE THAN 15 FT.
VENT SUPPORTS
ARE PER VENT
MANUFACTURER'S
SPECIFICATIONS.
Note:
A rise of 1/4 inch
per foot of horizontal
run is required.
Note:
A rise of 1/4 inch per foot of horizontal run is required.
Note:
Other vent
components are
noted in Figure 2.2
5
5
Vent Information and Diagrams
B. Vent System Confi guration
Figure 5.1
A. Vent Guidelines
Figure 5.2
Rise to Run Ratio = 2:1
Maximum Total Horizontal Run = 15 Feet
Minimum Total Vertical Rise = 9 Feet
Maximum Total Vertical Rise = 30 Feet
Maximum Number of Elbows: Two 90
0
or Four 45
0
This model requires the following size B-vent double wall,
or single wall rigid or fl ex vent pipe.
Fire Risk.
Asphyxiation Risk.
This appliance requires the specifi ed pipe for
operation.
• Incorrect pipe may cause spillage, condensation
and overheating.
• Follow pipe manufacturer’s installation guidelines when
installing the appliance.
Models
Pipe Size
8000TV-OAK
6 inch
WARNING
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a chimney
fl ue serving a separate solid-fuel or gas burning
appliance.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
May impair safe operation of this appliance or
other appliances connected to the fl ue.
CAUTION
ALL vent confi guration specifi cations MUST be followed.
• This product is tested and listed to these specifi cations.
• Appliance performance will suffer if specifi cations are not
followed.
WARNING
Note:
Other vent
components are
noted in Figure 2.2