pressure. We recommend a flexible line to
avoid undue mechanical load on the valve
and to ease thread alignment, but refer to
local codes.
•
CAUTION: Check Gas Type!
G
AS
S
UPPLY
This appliance and its individual shutoff
valve must be disconnected from the gas
supply piping system during any pressure
testing of that system at test pressures in
excess of ½ psig. The Tucson must be
isolated from the gas supply piping system
by closing its individual manual shutoff
valve during any pressure testing of the gas
supply piping system at test pressures equal
to or greater than ½ psig.
G
AS
P
RESSURE
A
DJUSTMENT
NOTE: A QUALIFIED TECHNICIAN
MUST PERFORM THIS PROCEDURE!
Once connected to the gas supply, the
supply line and manifold gas pressures must
be tested. The supply line pressure is tested,
to ensure it meets the minimum gas supply
pressure as listed in the Specifications for
the type of fuel in use (natural gas or LP), by
connecting a manometer to the supply line
and adjusting the incoming pressure if
necessary to meet the required supply line
pressure as listed in specifications. The
manifold pressure tap on the gas control
valve, refer to
Figure 20
for location.
L
OG
P
LACEMENT
CAUTION:
Fragile! Handle log set with
care. Always wear gloves and safety goggles
while handling the log set.
Only the decorative ceramic log set supplied
with the unit should be placed in the firebox.
Do not place any other ceramic logs, wood
logs, or other materials in the firebox. If the
log set is damaged or broken contact your
dealer for replacement. The decorative
ceramic log set will last a long time,
however, they will break if subjected to
rough or improper handling. Exact
positioning of the log set is required in order
to obtain a pleasing flame pattern and
efficient combustion. Incorrect log
placement may cause carbon build-up;
excess thermal stress on the log set and
stove parts, reduced efficiency, and high
levels of carbon monoxide. If the log set
does not set into the firebox exactly as
outlined, contact your dealer for assistance.
I
NSTALLATION OF THE
L
OG
S
ET
(Refer to the following images in this section
for log set assembly)
1.
Open the front door using a 1/8”
Allen wrench. Loosen the bolt that
fastens the doorknob to the door. It
also unfastens the door from the
firebox by turning it
counterclockwise. Be careful not to
chip the enamel when loosening the
bolt. Pull the door open by grabbing
the top edge of the doorframe.
2.
Remove the packaging material
around the log set assembly. Be
careful not to damage the log set
when unpacking. Observe the 4
mounting “posts”, Right, Rear, Left,
and Front.