background image

HearthStone Quality Home Heating Products Inc 

® 

                                                                                                                                                                     Heritage Model 8021            

4

P

ERIODIC 

C

HECKLIST

 

 
Perform each of these tasks at the specified intervals. 
 

At the End of Every Week: 

• 

Empty ashes from the firebox and ash pan, sooner if 
the firebox or the ash pan begins to fill up. 

 

At the Beginning of Every Other Month: 

• 

A visual inspection of the chimney connector and 
chimney for creosote is recommended depending 
upon your use of the stove. (Please see page 19) 

• 

Check door seals using the "dollar bill test." - When 
the fire is out and the stove is cool, shut the door on a 
dollar bill.  If the bill pulls out without any resistance, 
then your stove’s door isn't sealed properly.  To 
tighten the seal, change the door gasket. (Refer to 
page 19.)

 

 
At the End of Every Season:

 

• 

Dismantle the chimney connector and clean it 
thoroughly.  Replace any pieces that show signs of 
rust or deterioration. 

• 

Inspect and, if necessary, clean your chimney. 

• 

Thoroughly clean out the inside of the stove. 

• 

Inspect all door gasket material and replace if worn, 
frayed, cracked or extremely hard. 

 

E

MERGENCY 

P

ROCEDURES

 

If you have a stovepipe or chimney fire, follow these 
instructions: 
 
1.  If the fire is too threatening, leave the area and call 

the fire department immediately!  If not, perform the 
next three steps. 

 
2.  Close the primary air control. 
 
3.  Close the stovepipe damper (if present). 
 
4.  Keep the stove front, side and ash doors closed! 

 

 

WARNING 

DO NOT ATTEMPT TO PUT OUT A STOVEPIPE 
OR CHIMNEY FIRE BY THROWING WATER 
ONTO THE STOVE, STOVEPIPE, OR 
CHIMNEY.  THE EXTREMELY HIGH 
TEMPERATURE ASSOCIATED WITH SUCH 
FIRES CAN CAUSE INSTANTANEOUS STEAM 
AND SERIOUS BODILY HARM. 

 
Once the chimney fire has expired, leave the primary air 
control closed and let the fire in the stove die out 
completely.  The stove should not be fired again until the 
stove, stovepipe, and chimney are all thoroughly 

inspected for any sign of damage.  You must correct any 
damage before using your stove again. 

 

S

PECIFICATIONS

 

 

Maximum Heat Output

.  55,000 BTUs per hour of 

cordwood (based on 
independent laboratory test 
results). 

 

Size Of Heated Area

1,500 to 2,000 square feet. 

 

Firebox Capacity.

 

2.2 cubic feet (.062 cubic 
meters) or 46 pounds of wood 
(The amount and weight of 
wood contained per cubic foot 
of firebox volume can vary 
from 15 to 36 lbs. per cubic 
foot depending on type of 
wood, moisture content, 
packing density and other 
factors.  As a constant for 
comparison and test purposes, 
we are assuming 20 lbs. of 
seasoned hardwood per cubic 
foot of firebox volume). 

 

Maximum Log Length

.  21" (53cm) - Front and 

 

 

 

Side doors 

Stove Dimensions 

Height

  29" (74 cm) 

Width

  29 1/2" (75 cm) 

Depth

  21.5" (55 cm) 

 

Front Door Size 

18" wide x 12" high  

 

 

(46 x 31 cm) 

 

Side Door Size

  9" wide x 10 x 9-5/8” high (25 x 24 cm) 

 

Stovepipe Size

  6" (152 mm) diameter 

 

Metal Chimney  

 6" (152 mm) inside diameter 

 

Masonry Chimney

  6” (15.2cm) inside diameter (round 

flue)  8” x 8” (20 x 20cm) (square  flue) 

 

Flue Exit 

Top or rear 

 

Actual Weight

  475 (216 kg) pounds 

 

Crate Dimensions

 H-38” (97cm) W-32”   (81 cm) L-32” 

(81 cm) 
 

Optional Equipment

 

Rear Heat Shield  90-68210 

   Outside 

Air 

Kit 

90-53210 

   Blower 

 90-57210 

 

Summary of Contents for Heritage 8021

Page 1: ...o reduce the risk of fire follow the installation instructions Failure to follow these instructions may result in property damage bodily injury or even death SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Heritage Model 8021 06 14 05 CONTACT LOCAL AUTHORITIES HAVING JURISDICTION BUILDING DEPARTMENT or FIRE OFFICIALS ABOUT PERMITS REQUIRED RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA ...

Page 2: ...ng to a Prefabricated Metal 11 Connection To A Masonry Chimney 11 INSTALLING IN A MOBILE HOME 14 OPERATING YOUR HERITAGE WOOD STOVE 15 CONTROLS AND FEATURES 15 CHOOSING FIREWOOD 16 BUILDING A FIRE 16 BREAKING IN YOUR WOOD STOVE 16 Building A Break In Fire 17 NORMAL OPERATION 17 Building A Fire For Everyday Use 17 Burn Rate 18 Over Fire Caution 18 Removal And Disposal Of Ashes 18 MAINTENANCE 19 Mon...

Page 3: ...cate your stove in a safe convenient open area away from traffic flow doors and hallways and near a chimney and chimney connector Review the proper clearance measurements from combustible surfaces You can safely reduce required clearances in most cases by using the optional rear heat shield and also with a special connector pipe and special wall coverings as specified by this manual the NFPA 211 c...

Page 4: ... fully inserted and the ash door closed tightly Inspect the stovepipe chimney connector and chimney as recommended Follow these safety precautions Never modify this stove in any way especially the primary air control system Never burn kiln dried wood painted or treated wood solvents trash plywood colored or glossy paper artificial logs cardboard coal garbage or driftwood Especially do not burn coa...

Page 5: ...A STOVEPIPE OR CHIMNEY FIRE BY THROWING WATER ONTO THE STOVE STOVEPIPE OR CHIMNEY THE EXTREMELY HIGH TEMPERATURE ASSOCIATED WITH SUCH FIRES CAN CAUSE INSTANTANEOUS STEAM AND SERIOUS BODILY HARM Once the chimney fire has expired leave the primary air control closed and let the fire in the stove die out completely The stove should not be fired again until the stove stovepipe and chimney are all thor...

Page 6: ...c has developed an advanced THERMO CERAMIC baffle system This system uses a lightweight durable ceramic material above the burner tubes to maintain the high temperatures in the secondary combustion area and maintain the low emission high efficiency combustion you desire This new technology will not corrode rust dissolve or lose its strength however it is vulnerable to puncture or cracking due to r...

Page 7: ...f radiant energy required to heat concrete basement walls is so great that most of the usable heat is absorbed by them and lost Read this chapter to obtain a sound understanding of how to properly install your stove If you use a close clearance connector pipe it must be tested to UL standards and listed Check the listing of your pipe for actual clearances The diagrams in this manual represent typi...

Page 8: ...sition 1 According to Intertek Testing Services Inc 2 According to ASHRAE Handbook of Fundamentals 1977 Ash Pan Door when closed the handle will be in the 7 o clock position To open the ash door rotate the latch counter clockwise to approximately the 6 clock position Side Door when closed the handle will be in the 5 o clock position To open the side door rotate the latch counter clockwise to appro...

Page 9: ...es inches A B C D E F G H I J K Single wall stove pipe without heatshield 17 16 18 21 30 1 2 13 2 12 22 25 1 2 65 Single wall stove pipe with heatshield 17 10 12 15 30 1 2 7 2 12 22 25 1 2 65 Double wall stove pipe with heatshield 15 7 9 12 29 4 0 11 21 24 1 2 63 1 2 Alcove Clearances inches Unprotected Surfaces Protected Surfaces NFPA 211 Minimum alcove width 61 49 Maximum alcove depth 48 48 Alco...

Page 10: ...HearthStone Quality Home Heating Products Inc Heritage Model 8021 9 ...

Page 11: ...lity of a house fire you must properly install and constantly maintain the venting system Upon inspection immediately replace rusted cracked or broken components The chimney connector is the stovepipe from the woodstove to the chimney The chimney connector stovepipe must be 6 152 mm diameter 24 MSG or 25 MSG blued steel connector pipe Do not use aluminum or galvanized steel pipe they cannot withst...

Page 12: ...e Whenever possible choose an interior chimney An interior chimney heats up more quickly and retains its heat thus promotes a better draft and discourages the formation of creosote An exterior chimney does not benefit from the warmth of being surrounded by the building so it typically operates at lower flue temperatures than an interior chimney An exterior chimney s draft is not as strong and may ...

Page 13: ...h enclosed chase One story house installation with attic Chimney Cap Storm Collar Flashing Chimney Sections Chase Enclosure Wall Strap Support Box with built in Starter Adjustable Roof Tee Tee clean out Access door Tee Support Bracket Chimney is supported by Tee Support Bracket Chimney is supported by Ceiling Chimney Cap Storm Collar Flashing Adjustable Roof section Insullation Shield Stovepipe Ch...

Page 14: ...east 1 25 mm air space An equivalent flue liner must be a listed chimney liner system meeting type HT requirements or other approved material Interior chimney requirements At least 2 51 mm clearance to combustible structure Fire stops must be installed at the spaces where the chimney passes through floors and or ceiling Insulation must be 2 51 mm from the chimney Exterior chimney requirements At l...

Page 15: ...96N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap storm collar Adjustable vented flashing 0 12 6 12 Two 24 Dura Plus chimney pipes 24 support box with built in starter section and trim UL or ULC approved equipment is acceptable Chimney must be removed when transporting Mobile Home WARNING DO NOT INSTALL IN A SLEEPING ROOM CAUTION MAINTAIN THE STRUCTURAL INTEGRITY OF TH...

Page 16: ... the stove just under the ash lip The primary air control allows you to regulate the amount of air entering the firebox Generally the more air allowed into the firebox the faster and hotter the rate of burn conversely less air creates a slower burn To fully open the primary air intake move the handle as far as it will go to the left move the handle as far as it will go to the right to close the pr...

Page 17: ...od should not be stored within the stove s specified clearances to combustible materials BUILDING A FIRE Once you understand the controls of your wood stove and have chosen the appropriate firewood you are ready to start a fire BREAKING IN YOUR WOOD STOVE It is imperative that your stove be broken in slowly Soapstone must be seasoned over firing a new stove may cause soapstone to crack or may dama...

Page 18: ...commend a visual inspection and cleaning if necessary of your stovepipe and chimney once the break in procedure is completed NORMAL OPERATION If your stove is not used continuously or has not been used in quite some time follow the break in procedure at least once to minimize the stress of a hot fire on a cold stove before proceeding with normal operation We recommend one break in fire at the star...

Page 19: ...emperatures above the recommended temperatures outlined above in the BURN RATE section Over firing should be carefully avoided since it will cause damage to the stove Symptoms of over firing include short burn times a roaring sound in the stove or stovepipe and discoloration of the stovepipe Over firing can be caused by excessive draft inappropriate fuel and operator error Correct an over fire sit...

Page 20: ...45 minutes daily to burn out creosote deposits from within the stove and the venting system 2 After reloading with wood burn the stove with the primary air control fully open for 20 to 30 minutes This manner of operation ensures early engagement of the secondary combustion system which when engaged minimizes creosote buildup in the chimney The stovepipe connector and chimney should be inspected at...

Page 21: ... or any other abrasive material to clean the glass Use low alkaline content cleaners only The front door glass is a ceramic shock resistant glass made specifically for use in woodstoves Do not use any replacement glass other than the ceramic glass manufactured and supplied for use in this woodstove Replacement glass is available through your local dealer The door glass should be replaced immediate...

Page 22: ...to monitor the temperature of the stack A 400 degree F 200 degree C stovepipe confirms the stove is supplying sufficient heat Keep in mind that your house itself will regulate room house temperatures How well the walls floors and ceilings are insulated the number and size of glass windows the tightness of outside doors and the construction or style of your house vaulted ceilings or other open spac...

Page 23: ...ey Seal chimney connections and openings in clean out doors More Than One Appliance Connected to the Flue Disconnect all other appliances and seal openings BACK PUFFING OR GAS EXPLOSIONS Operating Technique Fully open the primary air control one minute before opening the door and keep it fully open for a few minutes after reloading Extra Low Burn Rate Burn the stove at a higher burn rate Chimney D...

Page 24: ...010 210 FOOT HER 5350 047 CRANK HANDLE ASH PAN BEN 2010 245 PRIMARY MANIFOLD HER 5021 010 PAN ASH HER 2010 242 SECONDARY MANIFOLD TOP HER 5021 035 CONTROL ROD ASH GRATE HER 2010 240 SECONDARY MANIFOLD BOTTOM HER 5021 037 HANDLE ASH GRATE CONTROL 2010 275 SIDE TRIM HER MISC 2010 220 DOOR ASH PAN HER 3030 038 GLASS IR 11 3 16 x18 15 16 x5mm HER 2010 215 ASH PAN FRAME HER 1 3110 056 GASKET ROPE 1 4 2...

Page 25: ... factory built Type HT chimney or masonry chimney WN 04380 INSPECTION IN YOUR AREA AND INSTALLATION TYPE OF FUEL Solid Wood Only CAUTION HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS SEE NAMEPLATE AND INSTRUCTIONS INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY VENT RE...

Page 26: ... physical damage or over loading of the Woodstove Firebox baffle the baffle above the secondary air tubes against breakage cracking or burn through Door handles and latch mechanisms against breakage This warranty expires on the fifth 5th anniversary of the Purchase Date LIMITED ONE YEAR WARRANTY HearthStone warrants the following parts of the Woodstove against the following occurrences that result...

Page 27: ...THE EXPIRATION OF THE EXPRESS LIMITED WARRANTIES CONTAINED HEREIN NO IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THE SUBJECT WOODSTOVE SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU THE WARRANTIES CONTAINED IN THIS DOCUMENT EXTEND ONLY TO THE ORIGIN...

Page 28: ...HearthStone or a Dealer as the case may be Thereafter the Original Purchaser is responsible for all shipping costs related to shipping Woodstove parts to and from HearthStone or a Dealer as the case may be Shipping cost for the Woodstove Within the first 1st year after the Purchase Date if the Original Purchaser is instructed to return the Woodstove to HearthStone or a Dealer for repair HearthSton...

Page 29: ...HearthStone Quality Home Heating Products Inc Heritage Model 8021 28 Notes ...

Reviews: