background image

HearthStone Quality Home Heating Products Inc 

® 

                                                                                                                                                                     Heritage Model 8021            

11

connectors or clean-out tees.  These accessories ease the 
inspection of your chimney, as well as allow you to easily 
dismantle the stovepipe (without moving the stove) when 
you periodically inspection the stovepipe connection and 
chimney.   
 
Install the stove as close as practical to the chimney, 
while maintaining all proper clearances.  Install stovepipe 
that is as short and as straight as possible.  Horizontal runs 
of stovepipe should always rise away from the stove a 
minimum of 1/4" per foot (21mm/m). 
 

Long runs of stovepipe to increase heat dispersal are not 
recommended

.  Using longer lengths of stovepipe or more 

connecting elbows than necessary increase the chances of 
draft resistance and the accumulation of creosote buildup. 
 
In general, you do not need to install a stovepipe damper 
with the Heritage.  Some installations, however, could 
benefit from a stovepipe damper, such as a tall chimney 
which can create a higher than normal draft.  In such 
cases, a damper can help regulate the draft.  The Heritage 
requires a draft between 0.06" wc and 0.1" wc.  For drafts 
above 0.1" wc, install a stovepipe damper.  This should be 
checked at installation time. 
 
Remember, the NFPA has recommended, minimum 
clearances for chimney connectors to combustibles such 
as walls and ceilings.  Once the stove is installed at safe 
distances from these combustible surfaces, it is important 
to maintain these connector clearances for the remainder 
of the installation.   

 
 

C

ONNECTING 

Y

OUR 

W

OOD 

S

TOVE

 

 
You can install your Heritage to a prefabricated metal 
chimney or a masonry chimney. 
 
 

Connecting to a Prefabricated Metal Chimney 

 

There are two ways to install a prefabricated metal 
chimney: 
 

• 

An 

interior

 installation where the chimney passes 

inside the residence through the ceiling and roof.  

 

• 

An 

exterior

 installation where the chimney passes 

through the wall behind the stove then up the outside 
of the residence.  

 
Whenever possible, choose an interior chimney.  An 
interior chimney heats up more quickly and retains its 

heat; thus promotes a better draft and discourages the 
formation of creosote.  An exterior chimney does not 
benefit from the warmth of being surrounded by the 
building, so it typically operates at lower flue 
temperatures than an interior chimney.  An exterior 
chimney’s draft is not as strong and may experience 
increased creosote accumulation. 
 
When connecting the Heritage to a prefabricated metal 
chimney, you must follow, precisely, the manufacturer's 
installation instructions.  Use only Type HT (2100 deg. 
F), prefabricated metal chimneys listed per UL 103 or 
ULC S629 standards. 
 

 

WARNING: 

DO NOT CONNECT THE STOVE TO A 
CHIMNEY FLUE SERVING ANOTHER 
APPLIANCE. 

 
Make sure the size of the chimney’s flue is appropriate for 
the Heritage.  The Heritage requires a 6" (152 mm) inside 
diameter flue for new installations.  A 6” diameter flue 
provides adequate draft and performance.  You can use an 
8" (203 mm) diameter existing flue with a reducer.  An 
oversized flue contributes to creosote accumulation.  (In 
this case, bigger is NOT better.) 
 
When purchasing a prefabricated chimney to install with 
your stove, be sure to also purchase from the same 
manufacturer the wall pass-through (or ceiling support 
package), "T" section package, fire-stops (when needed), 
insulation shield, roof flashing, chimney cap, and any 
other needed accessories.  Follow the manufacturer’s 
instructions when installing the chimney and accessories.  
In addition, be sure to maintain all manufacturers’ 
recommendations for the proper clearances to the 
chimney. 
 
 

C

ONNECTION 

T

A M

ASONRY 

C

HIMNEY 

 

 

Consider two primary elements when connecting your 
stove to a masonry chimney: the chimney itself and the 
thimble where the stovepipe connects to the chimney.  
Use only Code approved masonry chimneys with a flue 
liner.  
 
Before connecting to a masonry chimney, hire a 
professional to examine the chimney for cracks, loose 
mortar, and other signs of deterioration and blockage.  If 
the chimney needs repair, complete them before installing 
and using your stove.  Do not install your stove until the 
chimney is safe for use. 

Summary of Contents for Heritage 8021

Page 1: ...o reduce the risk of fire follow the installation instructions Failure to follow these instructions may result in property damage bodily injury or even death SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Heritage Model 8021 06 14 05 CONTACT LOCAL AUTHORITIES HAVING JURISDICTION BUILDING DEPARTMENT or FIRE OFFICIALS ABOUT PERMITS REQUIRED RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA ...

Page 2: ...ng to a Prefabricated Metal 11 Connection To A Masonry Chimney 11 INSTALLING IN A MOBILE HOME 14 OPERATING YOUR HERITAGE WOOD STOVE 15 CONTROLS AND FEATURES 15 CHOOSING FIREWOOD 16 BUILDING A FIRE 16 BREAKING IN YOUR WOOD STOVE 16 Building A Break In Fire 17 NORMAL OPERATION 17 Building A Fire For Everyday Use 17 Burn Rate 18 Over Fire Caution 18 Removal And Disposal Of Ashes 18 MAINTENANCE 19 Mon...

Page 3: ...cate your stove in a safe convenient open area away from traffic flow doors and hallways and near a chimney and chimney connector Review the proper clearance measurements from combustible surfaces You can safely reduce required clearances in most cases by using the optional rear heat shield and also with a special connector pipe and special wall coverings as specified by this manual the NFPA 211 c...

Page 4: ... fully inserted and the ash door closed tightly Inspect the stovepipe chimney connector and chimney as recommended Follow these safety precautions Never modify this stove in any way especially the primary air control system Never burn kiln dried wood painted or treated wood solvents trash plywood colored or glossy paper artificial logs cardboard coal garbage or driftwood Especially do not burn coa...

Page 5: ...A STOVEPIPE OR CHIMNEY FIRE BY THROWING WATER ONTO THE STOVE STOVEPIPE OR CHIMNEY THE EXTREMELY HIGH TEMPERATURE ASSOCIATED WITH SUCH FIRES CAN CAUSE INSTANTANEOUS STEAM AND SERIOUS BODILY HARM Once the chimney fire has expired leave the primary air control closed and let the fire in the stove die out completely The stove should not be fired again until the stove stovepipe and chimney are all thor...

Page 6: ...c has developed an advanced THERMO CERAMIC baffle system This system uses a lightweight durable ceramic material above the burner tubes to maintain the high temperatures in the secondary combustion area and maintain the low emission high efficiency combustion you desire This new technology will not corrode rust dissolve or lose its strength however it is vulnerable to puncture or cracking due to r...

Page 7: ...f radiant energy required to heat concrete basement walls is so great that most of the usable heat is absorbed by them and lost Read this chapter to obtain a sound understanding of how to properly install your stove If you use a close clearance connector pipe it must be tested to UL standards and listed Check the listing of your pipe for actual clearances The diagrams in this manual represent typi...

Page 8: ...sition 1 According to Intertek Testing Services Inc 2 According to ASHRAE Handbook of Fundamentals 1977 Ash Pan Door when closed the handle will be in the 7 o clock position To open the ash door rotate the latch counter clockwise to approximately the 6 clock position Side Door when closed the handle will be in the 5 o clock position To open the side door rotate the latch counter clockwise to appro...

Page 9: ...es inches A B C D E F G H I J K Single wall stove pipe without heatshield 17 16 18 21 30 1 2 13 2 12 22 25 1 2 65 Single wall stove pipe with heatshield 17 10 12 15 30 1 2 7 2 12 22 25 1 2 65 Double wall stove pipe with heatshield 15 7 9 12 29 4 0 11 21 24 1 2 63 1 2 Alcove Clearances inches Unprotected Surfaces Protected Surfaces NFPA 211 Minimum alcove width 61 49 Maximum alcove depth 48 48 Alco...

Page 10: ...HearthStone Quality Home Heating Products Inc Heritage Model 8021 9 ...

Page 11: ...lity of a house fire you must properly install and constantly maintain the venting system Upon inspection immediately replace rusted cracked or broken components The chimney connector is the stovepipe from the woodstove to the chimney The chimney connector stovepipe must be 6 152 mm diameter 24 MSG or 25 MSG blued steel connector pipe Do not use aluminum or galvanized steel pipe they cannot withst...

Page 12: ...e Whenever possible choose an interior chimney An interior chimney heats up more quickly and retains its heat thus promotes a better draft and discourages the formation of creosote An exterior chimney does not benefit from the warmth of being surrounded by the building so it typically operates at lower flue temperatures than an interior chimney An exterior chimney s draft is not as strong and may ...

Page 13: ...h enclosed chase One story house installation with attic Chimney Cap Storm Collar Flashing Chimney Sections Chase Enclosure Wall Strap Support Box with built in Starter Adjustable Roof Tee Tee clean out Access door Tee Support Bracket Chimney is supported by Tee Support Bracket Chimney is supported by Ceiling Chimney Cap Storm Collar Flashing Adjustable Roof section Insullation Shield Stovepipe Ch...

Page 14: ...east 1 25 mm air space An equivalent flue liner must be a listed chimney liner system meeting type HT requirements or other approved material Interior chimney requirements At least 2 51 mm clearance to combustible structure Fire stops must be installed at the spaces where the chimney passes through floors and or ceiling Insulation must be 2 51 mm from the chimney Exterior chimney requirements At l...

Page 15: ...96N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap storm collar Adjustable vented flashing 0 12 6 12 Two 24 Dura Plus chimney pipes 24 support box with built in starter section and trim UL or ULC approved equipment is acceptable Chimney must be removed when transporting Mobile Home WARNING DO NOT INSTALL IN A SLEEPING ROOM CAUTION MAINTAIN THE STRUCTURAL INTEGRITY OF TH...

Page 16: ... the stove just under the ash lip The primary air control allows you to regulate the amount of air entering the firebox Generally the more air allowed into the firebox the faster and hotter the rate of burn conversely less air creates a slower burn To fully open the primary air intake move the handle as far as it will go to the left move the handle as far as it will go to the right to close the pr...

Page 17: ...od should not be stored within the stove s specified clearances to combustible materials BUILDING A FIRE Once you understand the controls of your wood stove and have chosen the appropriate firewood you are ready to start a fire BREAKING IN YOUR WOOD STOVE It is imperative that your stove be broken in slowly Soapstone must be seasoned over firing a new stove may cause soapstone to crack or may dama...

Page 18: ...commend a visual inspection and cleaning if necessary of your stovepipe and chimney once the break in procedure is completed NORMAL OPERATION If your stove is not used continuously or has not been used in quite some time follow the break in procedure at least once to minimize the stress of a hot fire on a cold stove before proceeding with normal operation We recommend one break in fire at the star...

Page 19: ...emperatures above the recommended temperatures outlined above in the BURN RATE section Over firing should be carefully avoided since it will cause damage to the stove Symptoms of over firing include short burn times a roaring sound in the stove or stovepipe and discoloration of the stovepipe Over firing can be caused by excessive draft inappropriate fuel and operator error Correct an over fire sit...

Page 20: ...45 minutes daily to burn out creosote deposits from within the stove and the venting system 2 After reloading with wood burn the stove with the primary air control fully open for 20 to 30 minutes This manner of operation ensures early engagement of the secondary combustion system which when engaged minimizes creosote buildup in the chimney The stovepipe connector and chimney should be inspected at...

Page 21: ... or any other abrasive material to clean the glass Use low alkaline content cleaners only The front door glass is a ceramic shock resistant glass made specifically for use in woodstoves Do not use any replacement glass other than the ceramic glass manufactured and supplied for use in this woodstove Replacement glass is available through your local dealer The door glass should be replaced immediate...

Page 22: ...to monitor the temperature of the stack A 400 degree F 200 degree C stovepipe confirms the stove is supplying sufficient heat Keep in mind that your house itself will regulate room house temperatures How well the walls floors and ceilings are insulated the number and size of glass windows the tightness of outside doors and the construction or style of your house vaulted ceilings or other open spac...

Page 23: ...ey Seal chimney connections and openings in clean out doors More Than One Appliance Connected to the Flue Disconnect all other appliances and seal openings BACK PUFFING OR GAS EXPLOSIONS Operating Technique Fully open the primary air control one minute before opening the door and keep it fully open for a few minutes after reloading Extra Low Burn Rate Burn the stove at a higher burn rate Chimney D...

Page 24: ...010 210 FOOT HER 5350 047 CRANK HANDLE ASH PAN BEN 2010 245 PRIMARY MANIFOLD HER 5021 010 PAN ASH HER 2010 242 SECONDARY MANIFOLD TOP HER 5021 035 CONTROL ROD ASH GRATE HER 2010 240 SECONDARY MANIFOLD BOTTOM HER 5021 037 HANDLE ASH GRATE CONTROL 2010 275 SIDE TRIM HER MISC 2010 220 DOOR ASH PAN HER 3030 038 GLASS IR 11 3 16 x18 15 16 x5mm HER 2010 215 ASH PAN FRAME HER 1 3110 056 GASKET ROPE 1 4 2...

Page 25: ... factory built Type HT chimney or masonry chimney WN 04380 INSPECTION IN YOUR AREA AND INSTALLATION TYPE OF FUEL Solid Wood Only CAUTION HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS SEE NAMEPLATE AND INSTRUCTIONS INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY VENT RE...

Page 26: ... physical damage or over loading of the Woodstove Firebox baffle the baffle above the secondary air tubes against breakage cracking or burn through Door handles and latch mechanisms against breakage This warranty expires on the fifth 5th anniversary of the Purchase Date LIMITED ONE YEAR WARRANTY HearthStone warrants the following parts of the Woodstove against the following occurrences that result...

Page 27: ...THE EXPIRATION OF THE EXPRESS LIMITED WARRANTIES CONTAINED HEREIN NO IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THE SUBJECT WOODSTOVE SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU THE WARRANTIES CONTAINED IN THIS DOCUMENT EXTEND ONLY TO THE ORIGIN...

Page 28: ...HearthStone or a Dealer as the case may be Thereafter the Original Purchaser is responsible for all shipping costs related to shipping Woodstove parts to and from HearthStone or a Dealer as the case may be Shipping cost for the Woodstove Within the first 1st year after the Purchase Date if the Original Purchaser is instructed to return the Woodstove to HearthStone or a Dealer for repair HearthSton...

Page 29: ...HearthStone Quality Home Heating Products Inc Heritage Model 8021 28 Notes ...