PROBLEM 

POSSIBLE CAUSE 

SOLUTIONS 

STOVE SMOKES 

Operating Technique 

Fully open the primary air control one minute before 
opening doors. 

 

Cold Chimney 

Preheat the chimney when first starting a fire. Briefly open a 
window in the room containing the stove. 

 

Blocked Chimney 

Examine the chimney and stovepipe for blockage or 
creosote accumulations. 

 

Oversized Chimney 

Reline the chimney to the appropriate diameter 

 

Undersized Chimney 

Install a draft inducer or replace the chimney. 

 

Chimney Too Short 

Lengthen the chimney. 

 

Air Infiltration Into The 
Chimney 

Seal chimney connections and openings such as clean-out 
doors. 

 

More Than One 
Appliance Connected to 
the Flue 

Disconnect all other appliances and seal openings. 

BACK-PUFFING 
OR GAS 
EXPLOSIONS 

Operating Technique 

Fully open the primary air control one minute before 
opening the door and keep it fully open for a few minutes 
after reloading. 

 

Extra Low Burn Rate 

Burn the stove at a higher burn rate. 

 

Chimney Down-draft 

Install a chimney cap. 

 

Excessive Ash Build-up 

Empty the ash pan more frequently. Increase efficiency of 
burns, and avoid using poor quality or green wood. 

UNCONTROLLED 
OR SHORT BURN 

Unsealed or Open Door 
Open ash grate 

Close the door tightly or replace the gaskets. 
Slide ash grate to closed position. 

 

Excessive Draft 

Check the installation. Operate at LOW BURN. Install 
stovepipe damper. 

 

Extra Long Chimney 

Shorten the chimney. Install stovepipe damper(s). 

 

Oversized Chimney 

Reline the chimney to the proper diameter. 

 

High Winds or Hilltop 
Location: 

Install a chimney cap. 
 

 

Excessive Draft 

Draft in excess of 0.1 WC should be corrected with a 
stovepipe damper(s) 

INSUFFICIENT 
HEAT 

Poor Quality or Green 
Wood 

Use only air-dried wood, preferably dried at least one year. 

 

Low Burn Rate 

Operate the stove at a higher burn rate. 

 

Air Insulated Chimney 

Replace with a pre-fabricated insulated chimney system or 
a properly sized masonry chimney. 

 

Cold Exterior Chimney 

Reline or insulate the chimney. 

 

Leaky Stovepipe or 
Chimney 

Check the installation. 

 

Too Much Heat Loss 
From House 

Add insulation, use energy efficient windows, or caulk 
windows, and seal openings in home. 

 

Excessive Ash Build-up 

Empty the ash pan more frequently. Increase efficiency of 
burns, and avoid using poor quality or green wood. 

BLISTERING OF 
FINISH 

Operating Technique 

Do not over-fire the stove. Monitor stove temperatures. Use 
seasoned wood only. 

 

Excessive Draft 

Check the DRAFT. A damper may be required. Operate the 
stove at a LOW BURN range. 

 

 

Summary of Contents for hase lima 8150

Page 1: ...HIS ENTIRE OWNER S MANUAL BEFORE YOU INSTALL AND USE YOUR NEW LIMA WOOD STOVE To reduce the risk of fire follow the installation instructions Failure to follow these instructions can result in propert...

Page 2: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 2 Intentionally Blank...

Page 3: ...OUTSIDE AIR SUPPLY 12 VENTING COMPONENTS AND CONFIGURATION REQUIREMENTS 12 INSTALLING A VENTING SYSTEM 13 CONNECTING THE STOVE TO A CHIMNEY 13 INSTALLING IN A MOBILE HOME 17 OPERATING YOUR LIMA WOOD S...

Page 4: ...a away from traffic flow doors and hallways If possible try to install the stove near an existing chimney and chimney connector It is extremely important to install this stove with the proper clearanc...

Page 5: ...y this stove in any way Never burn kiln dried painted or treated wood in this stove Never burn garbage or trash colored or glossy paper solvents plywood artificial logs cardboard or driftwood in this...

Page 6: ...INSTANTANEOUS STEAM AND SERIOUS BODILY HARM Once the chimney fire expires leave the primary air control closed and let the fire in the stove die out completely Inspect the stove stovepipe and chimney...

Page 7: ...ase You must carefully consider the clearances to all of these combustibles before actually connecting your stove If the floor is made of combustible material then a non combustible floor protector is...

Page 8: ...own in previous figures are from the body of the stove The Lima wood stove has a unique feature that allows it to rotate This rotation allows positioning the body of the stove into 13 different positi...

Page 9: ...ne Quality Home Heating Products Inc Lima Model 8150 9 Figure 4 Remove Mounting Screw Figure 5 Insert First Rotation Locking Stopper Figure 6 Insert Second Rotation Lock Stopper Figure 7 Tighten Mount...

Page 10: ...n Position G H E A C D Stove Free to Rotate B F J Stove Locked in Position I K Figure 8 Clearance to combustibles Parallel Corner Clearances A B C D E F G H I J K Single or double wall Inches 38 17 26...

Page 11: ...a ventilated thimble minimum 24 gauge in thickness having two 1in air channels separated from combustibles by a minimum of 6in of glass fiber insulation Opening shall be covered and thimble supported...

Page 12: ...talbestos DS Security GSW and Ameritec also have acceptable close clearance connector pipe When used in a mobile home a spark arrester is required See page 16 The chimney connector cannot pass through...

Page 13: ...n create a higher than normal draft In such cases a damper can help regulate the draft The Lima requires a draft between 0 06 and 0 1 WC For drafts above 0 1 WC install a stovepipe damper Check the dr...

Page 14: ...versized flue contributes to the accumulation of creosote Use the following checklist to ensure that your masonry chimney meets these minimum requirements Masonry Chimney wall construction Mortared br...

Page 15: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 15 Figure 10 Typical Venting Configurations...

Page 16: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 16 Figure 11 Chimney Height Roof Clearance Requirements 3 0 MINIMUM 10 0 2 0 MINIMUM 3 0 MINIMUM 2 0 MINIMUM...

Page 17: ...all one of the following Dura Vent Mobile Home Chimney Connector Kits 6DP MH 6 Diameter S N 9096N 7DP MH 7 Diameter S N 9196N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap...

Page 18: ...pen the control door and locate the ash pan s handle To remove the ash pan grip the handle rotate it clockwise turn and then pull it out The lid for the ash pan is stored under the ash pan Use the lid...

Page 19: ...d with higher a BTU content is generally considered ideal for a wood stove WOOD HEAT VALUE Common Name Lb cord MBTU cord High Osage Orange Hedge 4 728 32 9 Hickory Shagbark 4 327 27 7 Hop Hornbeam Iro...

Page 20: ...alleviate these odors by opening a few windows or otherwise creating additional ventilation around your stove If any odor persists contact your dealer or an authorized service technician If you adhere...

Page 21: ...lations may require more than one damper INAPPROPRIATE FUEL Do not burn coal kiln dried lumber wax logs or anything other than natural cordwood OPERATOR ERROR Ensure all the gaskets are in good condit...

Page 22: ...ey at the top where it is coolest as well as from the bottom near the stove 6 Remove accumulated creosote with a cleaning brush specifically designed for the type of chimney in use Use a certified chi...

Page 23: ...gasket was not fully inserted into the channel or where stretched thinner or adjacent to an area where the gasket was compressed thicker 6 First adjust the gasket as necessary by reseating it uniform...

Page 24: ...glass immediately if broken or chipped Contact your local dealer for replacement glass The glass kit includes instructions and everything needed for the repair If you replace the glass yourself wear...

Page 25: ...y placing each one into the right most position and then slide it to the left All side panels are identical 7 Replace the side panel lock plate 8 Push side panels together tightly and center them so t...

Page 26: ...as follows An AIRTIGHT HOUSE The air supply infiltration to the interior of the house may be inadequate if your home is super insulated or especially well sealed This phenomenon of air starvation wit...

Page 27: ...ing poor quality or green wood UNCONTROLLED OR SHORT BURN Unsealed or Open Door Open ash grate Close the door tightly or replace the gaskets Slide ash grate to closed position Excessive Draft Check th...

Page 28: ...Y AIR PIPE 605 132 V ASH PAN FA ADE 360 080 V3 ASH TRAY 2 2110 701 ASH GRATE ROTATING 360 077 V ASH TRAY COVER 2110 700 ASH GRATE BASE 635 052 V3 ASH GRATE PLATE CAST 4700 200555 GRATE ROD 780 017 V U...

Page 29: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 29 Safety Label...

Page 30: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 30 Notes...

Page 31: ...The Original Purchaser should complete their warranty registration on our website at http www hearthstonestoves com customer resources warranty registration NOTE FILLING OUT THE WARRANTY REGISTRATION...

Reviews: