HearthStone hase lima 8150 Owner'S Manual Download Page 22

Hearthstone 

Quality Home Heating Products, Inc 

®                                                                                                                                                                      Lima Model 8150            

22 

Maintenance 

 

 

NOTE:  ANY  SYMPTOMS  OF  OVER-FIRING  WILL 
VOID YOUR WARRANTY! 

C

REOSOTE 

F

ORMATION 

&

 

N

EED 

F

OR 

R

EMOVAL 

 

When  wood  burns  slowly  at  low  temperatures,  it 
produces  tar  and  other  organic  vapors,  which 
combine  with  expelled  moisture  to  form  creosote. 
These  creosote  vapors  condense  in  the  relatively 
cool chimney flue of a slow-burning fire. As a result, 
creosote  residue  accumulates  on  the  flue  lining. 
When ignited, this creosote makes an extremely hot 
fire, which may damage the chimney or even destroy 
the house. When burning wood, inspect the chimney 
connector  and  chimney  at  least  once  every  two 
months  during  the  heating  season  to  determine  if 
there is a creosote buildup. 

T

O PREVENT THE BUILDUP OF CREOSOTE

1.  Burn  the  stove  with  the  primary  air  control  fully 

open  for  35  -  45  minutes  daily  to  burn  out 
creosote  deposits  from  within  the  stove  and  the 
venting system. 

2.  After  reloading  with  wood,  burn  the  stove  with 

the  primary  air  control  fully  open  for  20  to  30 
minutes. This manner of operation ensures early 
engagement  of  the  secondary  combustion 
system  that  minimizes  creosote  buildup  in  the 
chimney. 

3.  If  a  creosote  build-up  occurs,  inspect  the 

stovepipe connector and chimney more often, at 
least  monthly  during  the  heating  season  to 
monitor  the  accumulation.  If  a  creosote  residue 
greater that 1/4" (6 mm) accumulates, remove it 
to reduce the risk of a chimney fire. 

4.  If  your  glass  always  remains  dirty,  your 

operating temperatures are too low or your wood 
is  wet;  therefore,  there  is  a  higher  risk  of 
creosote buildup. 

5.  Inspect  the  venting  system  at  the  stove 

connection 

and

  at  the  chimney  top.  Cooler 

surfaces  tend  to  build  creosote  deposits  faster, 
so it is important to check the chimney at the top 
(where  it  is  coolest)  as  well  as  from  the  bottom 
near the stove. 

6.  Remove  accumulated  creosote  with  a  cleaning 

brush  specifically  designed  for  the  type  of 
chimney  in  use.  Use  a  certified  chimney  sweep 
to  perform  this  service.  Contact  your  dealer  for 

the  name  of  a  certified  chimney  sweep  in  your 
area (your dealer may be a certified sweep!).  

7.  We  recommend  that  before  each  heating 

season 

you 

have 

the 

entire 

system 

professionally  inspected,  cleaned  and  repaired, 
if necessary. 

D

OOR 

R

EMOVAL 

P

ROCEDURE

1.  Open  the  door  and  remove  the  push  nut  from 

the upper hinge pin, and remove the pin.  

2.  Tilt the top of the door outward, and then lift the 

door  up  off  the  lower  pin.  The  door  weighs  81 
pounds (37 kg) 

– so use a helper if necessary. 

3.  Ensure  the  brass  washer  remains  in  place  on 

the lower pin. 

4.  Place  the  door  face  down  on  a  padded  work 

surface.  Use  two  rolled  up  towels,  or  similar, 
under  the  door  to  stabilize  the  curved  door 
during maintenance. 

5.  When  reinstalling  the  door,  use  a  new  push  nut 

on the upper hinge pin. 

G

ASKETS 

 

Replace  door  gasket  material  every  two  to  three 
seasons,  depending  on  stove  use.  If  the  door  seal 
leaks,  a  new  gasket  will  ensure  a  tight  seal  and 
improve stove performance.  

We  recommend  you  only  use  Hearthstone  Hase 
Collection  replacement  gaskets  and  adhesive  when 
you  need to replace  your door gasket. Contact  your 
dealer  for  a  gasket  kit  that  includes  instructions, 
adhesive, and the gasket for your stove. 

Required  Door  Gasket

:  Part  Number:  3110-

205274, (20mm x 7.5mm x 2000mm). 

D

OOR 

G

ASKET 

R

EPLACEMENT 

P

ROCEDURES

1.  To  replace  the  door  gasket,  remove  the  door 

from  the  stove  (see  door  removal  instructions 
above), and remove the  door’s side plates. Pull 
off the old rope gasket. Carefully remove any old 
gasket  material  and  adhesive  with  a  small 
screwdriver, or cold chisel and a hammer. Clean 
all  gasket  channels  with  a  small  wire  brush  if 
necessary.  

2.  Vacuum  the  inside  of  the  door  as  required. 

Loosely re-

attach the door’s side plates.  

Summary of Contents for hase lima 8150

Page 1: ...HIS ENTIRE OWNER S MANUAL BEFORE YOU INSTALL AND USE YOUR NEW LIMA WOOD STOVE To reduce the risk of fire follow the installation instructions Failure to follow these instructions can result in propert...

Page 2: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 2 Intentionally Blank...

Page 3: ...OUTSIDE AIR SUPPLY 12 VENTING COMPONENTS AND CONFIGURATION REQUIREMENTS 12 INSTALLING A VENTING SYSTEM 13 CONNECTING THE STOVE TO A CHIMNEY 13 INSTALLING IN A MOBILE HOME 17 OPERATING YOUR LIMA WOOD S...

Page 4: ...a away from traffic flow doors and hallways If possible try to install the stove near an existing chimney and chimney connector It is extremely important to install this stove with the proper clearanc...

Page 5: ...y this stove in any way Never burn kiln dried painted or treated wood in this stove Never burn garbage or trash colored or glossy paper solvents plywood artificial logs cardboard or driftwood in this...

Page 6: ...INSTANTANEOUS STEAM AND SERIOUS BODILY HARM Once the chimney fire expires leave the primary air control closed and let the fire in the stove die out completely Inspect the stove stovepipe and chimney...

Page 7: ...ase You must carefully consider the clearances to all of these combustibles before actually connecting your stove If the floor is made of combustible material then a non combustible floor protector is...

Page 8: ...own in previous figures are from the body of the stove The Lima wood stove has a unique feature that allows it to rotate This rotation allows positioning the body of the stove into 13 different positi...

Page 9: ...ne Quality Home Heating Products Inc Lima Model 8150 9 Figure 4 Remove Mounting Screw Figure 5 Insert First Rotation Locking Stopper Figure 6 Insert Second Rotation Lock Stopper Figure 7 Tighten Mount...

Page 10: ...n Position G H E A C D Stove Free to Rotate B F J Stove Locked in Position I K Figure 8 Clearance to combustibles Parallel Corner Clearances A B C D E F G H I J K Single or double wall Inches 38 17 26...

Page 11: ...a ventilated thimble minimum 24 gauge in thickness having two 1in air channels separated from combustibles by a minimum of 6in of glass fiber insulation Opening shall be covered and thimble supported...

Page 12: ...talbestos DS Security GSW and Ameritec also have acceptable close clearance connector pipe When used in a mobile home a spark arrester is required See page 16 The chimney connector cannot pass through...

Page 13: ...n create a higher than normal draft In such cases a damper can help regulate the draft The Lima requires a draft between 0 06 and 0 1 WC For drafts above 0 1 WC install a stovepipe damper Check the dr...

Page 14: ...versized flue contributes to the accumulation of creosote Use the following checklist to ensure that your masonry chimney meets these minimum requirements Masonry Chimney wall construction Mortared br...

Page 15: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 15 Figure 10 Typical Venting Configurations...

Page 16: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 16 Figure 11 Chimney Height Roof Clearance Requirements 3 0 MINIMUM 10 0 2 0 MINIMUM 3 0 MINIMUM 2 0 MINIMUM...

Page 17: ...all one of the following Dura Vent Mobile Home Chimney Connector Kits 6DP MH 6 Diameter S N 9096N 7DP MH 7 Diameter S N 9196N 8DP MH 8 Diameter S N 9296N Each kit includes Stainless spark arrester cap...

Page 18: ...pen the control door and locate the ash pan s handle To remove the ash pan grip the handle rotate it clockwise turn and then pull it out The lid for the ash pan is stored under the ash pan Use the lid...

Page 19: ...d with higher a BTU content is generally considered ideal for a wood stove WOOD HEAT VALUE Common Name Lb cord MBTU cord High Osage Orange Hedge 4 728 32 9 Hickory Shagbark 4 327 27 7 Hop Hornbeam Iro...

Page 20: ...alleviate these odors by opening a few windows or otherwise creating additional ventilation around your stove If any odor persists contact your dealer or an authorized service technician If you adhere...

Page 21: ...lations may require more than one damper INAPPROPRIATE FUEL Do not burn coal kiln dried lumber wax logs or anything other than natural cordwood OPERATOR ERROR Ensure all the gaskets are in good condit...

Page 22: ...ey at the top where it is coolest as well as from the bottom near the stove 6 Remove accumulated creosote with a cleaning brush specifically designed for the type of chimney in use Use a certified chi...

Page 23: ...gasket was not fully inserted into the channel or where stretched thinner or adjacent to an area where the gasket was compressed thicker 6 First adjust the gasket as necessary by reseating it uniform...

Page 24: ...glass immediately if broken or chipped Contact your local dealer for replacement glass The glass kit includes instructions and everything needed for the repair If you replace the glass yourself wear...

Page 25: ...y placing each one into the right most position and then slide it to the left All side panels are identical 7 Replace the side panel lock plate 8 Push side panels together tightly and center them so t...

Page 26: ...as follows An AIRTIGHT HOUSE The air supply infiltration to the interior of the house may be inadequate if your home is super insulated or especially well sealed This phenomenon of air starvation wit...

Page 27: ...ing poor quality or green wood UNCONTROLLED OR SHORT BURN Unsealed or Open Door Open ash grate Close the door tightly or replace the gaskets Slide ash grate to closed position Excessive Draft Check th...

Page 28: ...Y AIR PIPE 605 132 V ASH PAN FA ADE 360 080 V3 ASH TRAY 2 2110 701 ASH GRATE ROTATING 360 077 V ASH TRAY COVER 2110 700 ASH GRATE BASE 635 052 V3 ASH GRATE PLATE CAST 4700 200555 GRATE ROD 780 017 V U...

Page 29: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 29 Safety Label...

Page 30: ...Hearthstone Quality Home Heating Products Inc Lima Model 8150 30 Notes...

Page 31: ...The Original Purchaser should complete their warranty registration on our website at http www hearthstonestoves com customer resources warranty registration NOTE FILLING OUT THE WARRANTY REGISTRATION...

Reviews: