28
Place the façade back onto the unit and tighten the clips with the phillips screwdriver.
Step Four:
Measure the opening of the fireplace. By measuring the fireplace cavity, you will need to
determine the following:
1. Will the flue collar be installed in the forward or aft position? The depth of the firebox will
determine the location of the flue collar.
NOTE
: the collar is installed at the factory in the aft
position. To change it to the forward position, follow the instructions in step five. Proceed to
the next step if the aft position is correct for your installation.
Reversable Flue
(Front-Back)
This end up !
3/8"
Medium
density
gasket
2. Is there sufficient clearance above the unit to install the flue liner to the installed flue collar? If
not, the baffle can be removed the flue collar can
P
HOTO
#6
Reversible door catch
P
HOTO
#7
Phillips screw in
hinge
F
IGURE
#1
The Flue Collar