The fireplace and its main burner valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psi
(3.5kPa).
5.
The fireplace must be isolated from the gas supply piping system by closing the gas shut-off
valve during any pressure testing of the gas supply system at test pressures equal to or less
than 1/2 psi (3.5kPa). After the gas supply has been connected, use a commercial gas leak
detector or apply a soapy water solution to all the fittings to check for gas leaks. Never use a
flame to test for leaks
.
Installing or Replacing the Batteries
1.
The valve control module is powered by four “AA”
batteries. The batteries are mounted within the
Valve Receiver Module located on the right side of
the fireplace attached to a drop-down mounting
bracket for easy accessibility. Refer to the adjacent
illustration.
2.
Loosen the thumb screw on the module drop-down
mounting bracket by turning counter-clockwise until
the threads are fully disengaged from the base
bracket.
3.
Rotate the Valve Receiver Module and mounting
bracket. Toward you 90 degrees.
4.
Slide off the Battery compartment cover.
5.
Install the 4 “AA” batteries, supplied, using the
guides inside the battery pack to show you the
correct battery orientation.
6.
Replace the battery compartment cover.
Rotate the Valve Receiver Module and
mounting bracket into its home position and
tighten the thumb screw to secure.
7.
The remote handset is powered by three
“AAA” batteries. The access panel is located
on the back of the handset and simply snaps
open to provide access to the battery
compartment. Install the three batteries as
shown on the label inside the remote control
battery compartment.