OWNER’S MANUAL Model # 8890 DVI-Ht
Page 8 of 32
SPECIFICATIONS
Listed:
Direct Vent Gas Fireplace
Model:
DVI-Ht Room Heater
Testing Agency:
Intertek Testing Services NA Inc. (ITS)
Tested to:
ANSI Z21.88-05 and CSA 2.33-05
Certified for use by:
Board of State Examiners of Plumbers and Gasfitters
100 Cambridge Street, Room 1511
Boston, Massachusetts 02202
This installation must conform with local codes or, in
the absence of local codes, the current National Fuel
Gas Code-ANSI Z223.1 (NFPA 54) or CAN/CGA
B149 Installation Code.
Installer l'appareil selon les codes ou règlements
locaux, ou, en l'absence de tels règlements, selon
les Codes d'installation CAN/CGA-B149
CAUTION: REPLACE ANY SCREENS OR
SAFETY GUARDS REMOVED FOR SERVICE
WORK PRIOR TO OPERATING THIS
APPLIANCE!
Specification Natural
Gas
LP
Input rating (Btu/hr)
33,000
33,000
Maximum output (BTU/hr)
26,900
26,200
Minimum input rating (Btu/hr)
13,000
12,000
Orifice size DMS 43,52
55,62
Man. pressure-HI setting (in. w.c./kPa)
3.5/1.15
10.0/0.8
Man. Pressure-Lo setting (in.w.c./kPa)
1.2/0.3
3.3/1.59
Inlet pressure-MAX (in. W.c./kPa) 10.5/2.6
14.0/3.47
Inlet pressure-MIN (in. W.c./kPa)
5.0/1.24
11.0/2.88
Conditionally approved for purchased mobile home
installation. This appliance may be installed in an
aftermarket permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a
qualified Hearthstone kit is used.
Cet appareil peut être installé dans un after market
situé définitivement, fabriqué (mobile) logement, où
ne prohibé pas par des codes ocaux.
Cet appareil est seulement pour l’emploi avec le type
de gaz indiqué sur l’assiette d’évaluation. Cet
appareil n’est pas décapotable pour l’emploi avec
autres gaz, à moins qu’un équipement certifié est
employé.
Figure 1: Firebox Dimensions