background image

2

that are attached to the wall switch by plugging in
the male to female connectors. (Connectors are pro-
vided and must be attached to the wall switch wires).
See Figure 2.

3. Turn the ON/OFF rocker switch to the "OFF" posi-

tion.

4. Attach the pigtail wires to the ends of the wires from

the wall switch by plugging in the male to female
connectors.

5. Turn the unit's ON/OFF rocker switch to the "OFF"

position.

2.0 INSTALLATION INSTRUCTIONS

FOR MODELS:  CFL-18-NG,
CFL-18-LP, CFL-24-NG, CFL-24-LP,
CFL-30-NG, CFL-30-LP, ST-CFL

2.1 INSTALLING THE WALL SWITCH

1. Install the wall switch in a convenient location and

run low voltage, 2-connector wire from the wall switch
into the fireplace in which the gas log set is installed.

2. Find the male to female connectors provided and

attach them to the ends of the wires that lead to the
wall switch.

3. Find the red and brown pigtail wires labeled "FOR

USE WITH REMOTE OR WALL SWITCH ONLY"
which are attached to the unit's ON/OFF rocker
switch.  Do NOT disconnect the existing wires at-
tached to this ON/OFF switch.  See Figure 3.

Figure 2

3.0 RECOMMENDED OPERATING

PROCEDURES

1. Follow the lighting instructions section in the fire-

place instruction manual.  Be certain that the pilot
light is on and the gas control valve is in the "ON"
position.  Be sure that the ON/OFF rocker switch is
in the "OFF" position.

2. Turn the wall switch "ON" to light the burner.

4.0 REPLACEMENT PARTS AND

CUSTOMER SERVICE

Replacement parts and service may be obtained through
your dealer.

Figure 3

WALL

SWITCH

PIGTAIL

WIRES

ROCKER

SWITCH

BLACK

SWITCH

BLACK

WIRE

ROCKER

SWITCH

PIGTAIL

WIRES

DOUBLE

CONNECTORS