VENTILATION AIR

AIR FOR COMBUSTION AND VENTILATION

Outlet 

Air 

Ventilated 

Attic  

Outlet

Air

Inlet

Air

Inlet Air 

Ventilated  

Crawl Space 

To  

Crawl 

Space 

To Attic 

Figure 2 - Ventilation Air from Inside 

Building

Figure 3 - Ventilation Air from Outdoors

Or

Remove

Door into

Adjoining

Room,

Option

3

Ventilation Grills 

Into Adjoining Room,

Option 2

Ventilation

Grills Into

Adjoining 

Room,

Option 1

12"

12"

Ventilation Air From Inside Building

This fresh air would come from an adjoining 

unconfined  space.  When  ventilating  to  an 

adjoining unconfined space, you must provide 

two permanent openings: one within 12" of the 

ceiling and one within 12" of the floor on the 

wall connecting the two spaces (see options 

1 and 2, Figure 2). You can also remove door 

into adjoining room (see option 3, Figure 2). 

Follow  the 

National Fuel Gas Code, ANSI 

Z223.1/NFPA 54, Air for Combustion and 

Ventilation

  for  required  size  of  ventilation 

grills or ducts.

Ventilation Air From Outdoors

Provide  extra  fresh  air  by  using  ventilation 

grills or ducts. You must provide two perma-

nent openings: one within 12" of the ceiling 

and one within 12" of the floor. Connect these 

items directly to the outdoors or spaces open 

to the outdoors. These spaces include attics 

and crawl spaces. Follow the 

National Fuel 

Gas Code, ANSI Z223.1/NFPA 54, Air for 

Combustion and Ventilation

 for required size 

of ventilation grills or ducts.

IMPORTANT:

  Do  not  provide  openings 

for  inlet  or  outlet  air  into  attic  if  attic  has  a 

thermostat-controlled power vent. Heated air 

entering the attic will activate the power vent. 

Rework worksheet, adding the space of the 

adjoining  unconfined  space. The  combined 

spaces must have enough fresh air to supply 

all appliances in both spaces.

The space in the above example is a confined 

space because the actual Btu/Hr used is more 

than the maximum Btu/Hr the space can sup-

port. You  must  provide  additional  fresh  air. 

Your options are as follows:
A.  Rework  worksheet,  adding  the  space 

of an adjoining room. If the extra space 

provides  an  unconfined  space,  remove 

door to adjoining room or add ventilation 

grills between rooms. See 

Ventilation Air 

From Inside Building.

B.  Vent room directly to the outdoors. See 

Ventilation Air From Outdoors

.

C.  Install a lower Btu/Hr heater, if lower Btu/

Hr size makes room unconfined. If the ac-

tual Btu/Hr used is less than the maximum 

Btu/Hr the space can support,

 

the space 

is an unconfined space. You will need no 

additional fresh air ventilation.

 WARNING: If the area in which 

the heater may be operated does 

not meet the required volume for 

indoor combustion air, combus-

tion and ventilation air shall be 

provided by one of the methods 

described in the National Fuel 

Gas Code, ANSI Z223.1/NFPA 

54,  the International Fuel Gas 

Code, or applicable local codes.

Summary of Contents for VF18LA-2

Page 1: ...in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and serv...

Page 2: ...n and Ventilation section on page 6 of this manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in s...

Page 3: ...igns the heater may not be working properly Get fresh air at once Have heater serviced Some people are more affected by carbon monoxide than oth ers These include pregnant women people with heart or l...

Page 4: ...ass doors closed If you operate heater with doors closed heat will build up inside fireplace and cause glass to burst If fireplace opening has vents at the bottom you must open the vents before operat...

Page 5: ...rchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts the gas cock must be a T handle type The State of Massachusetts requires that a flexible appliance connector cannot exc...

Page 6: ...y for the application including ample combustion air and circulation air 2 If high humidity is experienced a dehu midifier may be used to help lower the water vapor content of the air 3 Do not use an...

Page 7: ...Maximum Btu Hr the space can support Example 2560 cu ft 72 49 m3 volume of space x 20 51 200 maximum Btu Hr the space can support Unusually Tight Construction The air that leaks around doors and windo...

Page 8: ...l Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic ha...

Page 9: ...re place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the heater in a bedroom or bathroom in a recreational vehi...

Page 10: ...SIZING REQUIREMENTS Minimum Firebox Size 18 Log Set Height 20 Depth 13 Front Width 26 Rear Width 20 24 Log Set Height 20 1 2 Depth 14 Front Width 30 Rear Width 22 Minimum Clearances For Side Combusti...

Page 11: ...is less than 12 you must install the fireplace hood accessory Even if noncombustible material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figures 5...

Page 12: ...not permit vent free operation 3 You prefer vented operation If reasons number 1 or 2 above apply you must permanently open chimney flue damper You must install the damper clamp accessory not provided...

Page 13: ...ly to fitting threads Connect approved flexible gas hose to gas regulator of heater see Figure 11 Note Never apply pipe sealant to flare fitting threads Hold gas regulator with a wrench when connectin...

Page 14: ...eptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice technician must connect heater to gas sup...

Page 15: ...4 WC If you do not reduce incom ing gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 14 Pointing the vent down protects it fro...

Page 16: ...ts for Natural Gas Gas Meter WARNING Testallgaspiping and connections internal and external to unit for leaks after installing or servicing Correct all leaks at once WARNING Neveruseanopen flame to ch...

Page 17: ...MILLIVOLT CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous opera tion Verify proper operation after servicing Note The millivolt v...

Page 18: ...s number will help you to identify the logs when installing After installing logs add decorative cinders around the grate base do not place any decorative cinders on logs or burner 1 Insert log 1 into...

Page 19: ...mproper burning will result During manufacturing fabricating and ship ping various components of this appliance are treated with certain oils films or bonding agents These chemicals are not harmful bu...

Page 20: ...his heater has a safety in terlock system Wait one 1 minute before lighting pilot again 8 Turn control knob counterclockwise to the ON position The main burner should light Set control knob to the de...

Page 21: ...e REMOTE position Note The burner may light if hand held re mote was on when selector switch was last turned off You can now turn the burner on and off with the hand held remote control unit IMPORTANT...

Page 22: ...se the thermocouple to cool which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 27 or 29 turn heater off see To Turn Off Gas to Ap pliance page 20 see Troubleshooting pag...

Page 23: ...t assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector for dust and dirt see Figure 32 3 B...

Page 24: ...tor button is pressed in there is no spark at ODS pilot 1 Ignitor electrode is posi tioned wrong Ignitor elec trode is broken 2 Ignitor electrode is not con nected to ignitor cable 3 Ignitor cable is...

Page 25: ...rner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 23 or replace burner orifice 2 Replace burner orific...

Page 26: ...lls or furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar produ...

Page 27: ...nty coverage for parts replaced under warranty PARTS UNDER WARRANTY PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer S...

Page 28: ...www usaprocom com 200067 01A 28 PARTS MODELS VF18NA 2 VF18LA 2 VF24NA 2 AND VF24LA 2 5 3 2 1 12 13 8 7 6 4 10 11 9 5 14 8 1 14 1 14 3 14 5 14 6 14 7 14 2 14 4 14 8 2 14 8 3 14 8 4 14 8 5 14 8 6...

Page 29: ...Pilot 1 8 RV81FI 3 RV81FI 3 Gas Pressure Regulator 1 9 PIMSC1 01 PIMSC1 01 PIMSC1 01 PIMSC1 01 Electronic Piezo Ignitor 1 10 RG01 1L RG01 1L RG01 1L RG01 1L Ambiance LightAssembly 1 11 RG01 1L B RG01...

Page 30: ..._________ ________________________________________________________________________ ________________________________________________________________________ ____________________________________________...

Page 31: ..._________ ________________________________________________________________________ ________________________________________________________________________ ____________________________________________...

Page 32: ...ller in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and...

Reviews: