3.  Frequently Asked Questions/Troubleshooting

Symptom

Possible Cause

Corrective Action

The IFT-ACM does not respond to 

commands from the IFT-RC400

If IFT-ACM was newly installed 

and not paired.

Refer to Section D9 and make sure that the pairing procedure 

has been followed especially if the IFT-ACM was newly in-

stalled.

The power cord between 

IFT-ACM and junction box is 

disconnected.

Refer to Section D6 and make sure the power cable is properly 

inserted into the IFT-ACM and the junction box.

IFT-ACM and IFT-ECM are not 

latched.

Refer to Section D4 and check the connection between the IFT-

ACM and IFT-ECM by making sure they are latched together.

IFT-RC400 display the following 

message on-screen: Call Dealer

Error: Fan

Convection blower 

malfunction.

Using an RMS voltage meter, check the voltage coming out of 

the fan port on the IFT-ACM when the fan is set to highest level 

on the IFT-RC400. If the voltage measured is close to 120V AC 

then power down the appliance and install a new fan and verify 

if the issue has been resolved.

Fuse in IFT-ACM is blown.

Using an RMS voltage meter, check the voltage coming out of 

the fan port on the IFT-ACM when the fan is set to highest level 

on the IFT-RC400. If voltage measured is closer to zero, then 

replace the IFT-ACM itself

IFT-ACM is not responding to 

IFT-RC400.

Follow steps listed in the first symptom.

Fan is not plugged into IFT-

ACM.

Check wiring and connections

Spade connectors are 

miswired.

Some Fans may be connected to the IFT-ACM using spade 

connectors. For safety, turn off the power to the appliance and 

check to see if the wires on either end of the spade connector 

do not match in color as they might be miswired.

IFT-RC400 display the following 

message on-screen: Call Dealer

Error: Lights

Ember/backlighting 

malfunction.

Using an RMS voltage meter, check the voltage coming out of 

the lights port on the IFT-ACM when the lights are set to high-

est level on the IFT-RC400. If the voltage measured is close to 

120V AC then power down the appliance and install a new light 

kit and verify if the issue has been resolved.

Fuse in IFT-ACM is blown.

Using an RMS voltage meter, check the voltage coming out of 

the lights port on the IFT-ACM when the lights are set to highest 

level on the IFT-RC400. If voltage measured is closer to zero, 

then replace the IFT-ACM itself.

IFT-ACM is not responding to 

IFT-RC400.

Follow steps listed in the first symptom.

Lights are not plugged into 

IFT-ACM.

Check wiring and connections.

LED controller is not 

functioning.

Some appliances come with an LED controller that plugs into 

the Lights port on the IFT-ACM. Verify the wiring and check 

that it is functioning. If not, replace and verify the problem is 

resolved.

IFT-RC400 display the following 

message on-screen: Call Dealer 

Error: Power Vent

Multiple causes.

Please refer to the troubleshooting guide that came with your 

Power Vent.

Lights are blinking and/or fan 

and Power Vent blowers are 

fluctuating.

Poor quality of power from 

local power station.

Check with customer if they are also noticing issues with  

other unrelated appliances and if other lighting fixtures are also 

blinking/dimming randomly. If so, install a surge suppressor be-

tween the hearth appliance and its power source.

IFT-RC400 display the following 

message on-screen: Fan will turn 

on within 3 minutes

Functioning as intended.

The appliance has a three minute delay timer before the fan is 

turned ON. This allows the air surrounding the appliance to be 

heated before being pushed into the room.

f i r e - p a r t s . c o m

Summary of Contents for IntelliFire IFT-ACM

Page 1: ...f any damaged system component Modification of the system component Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hear...

Page 2: ...th an IFT RC150 or IFT RC400 See Section 2E 10 After pairing is complete you can verify that the IFT ECM recognizes the IFT ACM with the kits that were also installed by observing the IFT RC400 screen...

Page 3: ...n LED will blink for 14 seconds During the 14 seconds it is normal for accessories such as lights or fan to energize momentarily WhilethegreenLEDontheIFT ECMisblinking tapanywhere onthegrayindicatorba...

Page 4: ...K RED BRN ORANGE PILOT GREEN MAIN IFT RC400 REMOTE CONTROL GRN WHT BLK RED BLK RED BLK BLK RED IFT RC150 WIRELESS WALL SWITCH OPTIONAL OPTIONAL OPTIONAL APPLIANCE ON OFF CONTROL BRN BLK WIRE ASSEMBLY...

Page 5: ...PIN RED BLK ORANGE PILOT GREEN MAIN GRN WHT BLK RED BLK RED BLK OPTIONAL OPTIONAL IFT RC400 REMOTE CONTROL RED BLK BRN BRN JUMPER WIRE BRN WIRE ASSEMBLY MODULE RESET SWITCH OPTIONAL ON SOME MODELS ONL...

Page 6: ...onnector do not match in color as they might be miswired IFT RC400 display the following message on screen Call Dealer Error Lights Ember backlighting malfunction Using an RMS voltage meter check the...

Page 7: ...se contact your Hearth Home Technologies dealer with any questions or concerns For the location of your nearest Hearth Home Technologies dealer please visit www hearthnhome com Hearth Home Technologie...

Reviews: