3
Hearth & Home Technologies • IFT-ACM Installation Instructions • 2326-988 • 9/16
E. Pairing the IFT-RC400 to the Electronic
Control Module (IFT-ECM)
CAUTION! Risk of Burns! DO NOT program the IFT
Remote Controls to the IFT-ECM when flame or cold
climate function is on or when appliance is hot.
1. On the IFT-ECM, move the ON/OFF/REMOTE switch to
the REMOTE position. The green LED will blink three
times. A few seconds later, an audible “beep” will occur
to indicate that the system is ready.
Note:
If the green LED continues to blink slowly (system
is searching for a clear channel), wait until it stops before
proceeding to step 2.
2. Locate the pairing hole on the IFT-ECM. See Figure 4
Using a paper clip or similar item, press and release
the pairing button. The IFT-ECM will “beep” once and
the green LED will blink for 14 seconds. During the 14
seconds, it is normal for accessories such as lights or
fan to energize momentarily.
While the green LED on the IFT-ECM is blinking, tap anywhere
on the gray indicator bar located at the top of the IFT-RC400
screen. Tap on the pairing function as shown in Figure 5. If
the IFT-RC400 has been paired successfully to the IFT-ECM,
a double audible ‘beep” will be heard from the IFT-ECM..
3. If the pairing is unsuccessful, repeat steps 2 & 3.
Note:
If additional components are added such
as blowers, lights or Power Vent after initial
pairing, the pairing process must be repeated
again to detect additional components.
NOTICE: Only one IFT-RC400 remote control and one
IFT-RC150 wireless wall switch can be programmed into
an IFT-ECM. To program both an IFT-RC400 and an IFT-
RC150 to an IFT-ECM, repeat the same steps separately
for the IFT-RC400 and the IFT-RC150.
Figure 4. Pairing IFT-ECM
REMOTE POSITION
PAIRING HOLE
GREEN LED
Figure 5. IFT-RC400 Wall Mount / Pairing Screen
f i r e - p a r t s . c o m